Toshiba IK-TF5C instruction manual Standard Connection, Connector Pin Assignments

Page 8

5.CONNECTION

5.1 Standard Connection

Lens

IK-TF5C

Less than 4 mm

Cable (not included)

 

DC IN 12V

 

Frame grabber board,

Monitor

DC power

image process

equipment etc.

supply

 

5. 2 Cautions on Connection

When connecting the camera cables, unplug the power source of the camera and the other equipment connected.

We suggest using a C mount lens made for a 3CCD camera.

When using another lens, the best camera performance of this camera may not be obtained.

(For example, low resolution may occur, focus may be lost through the range of a zoom lens, and flare, ghost or shading may occur)

Furthermore, in order to avoid damaging the mounting portion of the camera head, use a lens which has projection dimension from the mounting base of less than 0.157"(4mm).

For DC power supply connecting to DC IN 12V terminal, use UL listed and/or CSA approved ungrounding type AC adaptor with the specifications described below.

Power supply voltage

: DC12V±10%

Current rating

: More than 830 mA

Ripple voltage

: Less than 50 mV(p–p)

Connector

: HR10A–7P–4S by HIROSE electronics Co. Ltd

 

Pins 1, 2

: 12V

 

Pins 3, 4

: GND

5. 3 Connector Pin Assignments

DC IN 12V

1+12V

2+12V

3GND

4GND

13

24

Connector used:

HR10A-7P-4PB

(HIROSE electronics

Co. Ltd) or equivalent.

DIGITAL

 

 

Function

I/O

1

GND

14

GND

 

2

X0-

15

X0+

 

O

3

X1-

16

X1+

 

O

 

 

 

 

 

 

4

X2-

17

X2+

 

O

 

 

 

 

 

 

5

Xcllk-

18

Xcllk+

 

O

 

 

 

 

 

 

6

X3-

19

X3+

 

O

 

 

 

 

 

 

7

SerTC+

20

SerTC-

Serial communication control (RXD)

I

8

SerTFC-

21

SerTFC+

Serial communication control (TXD)

O

9

CC1-

22

CC1+

Trigger pulse input

I

10

CC2+

23

CC2-

Partial scanning control

I

11

CC3-

24

CC3+

External HD input

I

12

CC4+

25

CC4-

External VD input

I

13

GND

26

GND

 

131

2614

Connector used:

12226-51000-00

(3M) or equivalent.

8

Image 8
Contents For Customer Use Following information is only for EU-member statesSafety Precautions Avoid setting in humid, smoky, vaporized or dusty places DisclaimerTable of Contents Components Items Controlled by Using on Screen Display Available selectionsNames and Functions Standard Connection Connector Pin AssignmentsConnection Operation White BalanceAutomatic White Balance Manual White Balance Outline Result displayed MeaningShutter speed mode is E.TRG mode GainShading Correction OFFMode Setting by on Screen Display Using the MenusChanging each setting in Manu mode Partial scanning settingMenus Shutter Electronic shutterChanging the shutter speed setting Changing each setting in SS synchro. scan modeMode = SS Changing each setting in E.TRG mode Changing each setting in 1P SNR modeChanging the polarity of inputting trigger pulse setting Changing 1P SNR exposure time settingChanging 1P SR exposure time setting Changing each setting in 1P SR modeMode = E.TRG E.TRG = 1P SR Changing each setting in PW SNR mode Mode = E.TRG E.TRG = PW SNRChanging each setting in PW SR mode Mode = E.TRG E.TRG = PW SRChanging each setting in RR mode Mode = E.TRG E.TRG = RRChanging each setting in Gain Changing the gain in Manu modeWHT BAL White balance Changing the shading correction mode Changing the manual shading correction settingChanging master pedestal Changing R pedestalAdjusting horizontal phase SyncOption Data UP, Down Menu UP, DownSetting to factory setting status External sync signal polarityShutter mode HD input VD input External SyncSetting by the frame Using the unit with external sync signalSetting by 1H Horizontal phase adjustment1P SNR 1 Pulse Trigger Sync Non Reset 1 Pulse Trigger SYNC-NON Reset Picture Output TimingEXT Trig External trigger Fval Lval DvalInternal VD*3 1P SR 1 Pulse Trigger Sync Reset 1 Pulse Trigger SYNC-RESET Picture Output TimingPW SNR Pulse width trigger SYNC-NON Reset About 7 ∝s PW SR Pulse width trigger SYNC-RESET 1 Pulse Width Trigger SYNC-RESET Picture Output TimingLong Term Exposure RR Reset restartInput Timing Chart Example When Partial Scanning Mode is on Partial ReadPartial Scanning OFF All pixels scanning Partial Scanning onInput Output Signal Specificatoins Vertical Output Waveform Timing Chart CCD Output Waveform Timing ChartHorizontal Output Waveform Timing Chart Specifications RGB, 3CCDSymptom Items to be checked External Appearance DiagramBefore Making a Service Call Imaging Systems Division Limited One 1 Year Warranty of Labor and PartsStep-by-step Procedures How to Obtain Warranty Service