Toshiba IK-TF5C Sync, Option, Data UP, Down Menu UP, Down, Adjusting horizontal phase

Page 21

( 5 ) SYNC

When an external sync signal is input, the display menu changes from INT (internal sync) to EXT (external sync) automatically.

Move up down

 

Set by pushing

 

By pushing

 

 

 

DATA UP, DOWN

 

MENU UP, DOWN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-- SYNC --

 

 

 

 

 

 

MODE

EXT

H PHASE

 

 

0

Sync system display

H PHASE -100 to 100

(5. 1) Adjusting horizontal phase

1Set the "" to H PHASE by pushing [MENU UP], [MENU DOWN] buttons.

2Adjust the horizontal phase by pushing [DATA UP], [DATA DOWN] buttons.

( 6 ) OPTION

(6. 1) Changing serial communication baud rate

1Set the "" to BAUD RATE by pushing [MENU UP], [MENU DOWN] buttons.

2Select either 9600 or 19200 by pushing [DATA UP], [DATA DOWN] buttons.

Move up down By pushing

MENU UP, DOWN

Set by pushing

DATA UP, DOWN

-- OPTION --

BAUD RATE 9600

• Serial baud rate 9600, 19200

21

Image 21
Contents Following information is only for EU-member states For Customer UseSafety Precautions Disclaimer Avoid setting in humid, smoky, vaporized or dusty placesTable of Contents Components Available selections Items Controlled by Using on Screen DisplayNames and Functions Connector Pin Assignments ConnectionStandard Connection White Balance OperationAutomatic White Balance Manual White Balance Outline Result displayed MeaningGain Shutter speed mode is E.TRG modeShading Correction OFFUsing the Menus Mode Setting by on Screen DisplayPartial scanning setting Changing each setting in Manu modeMenus Shutter Electronic shutterChanging each setting in SS synchro. scan mode Mode = SSChanging the shutter speed setting Changing each setting in 1P SNR mode Changing each setting in E.TRG modeChanging the polarity of inputting trigger pulse setting Changing 1P SNR exposure time settingChanging each setting in 1P SR mode Mode = E.TRG E.TRG = 1P SRChanging 1P SR exposure time setting Mode = E.TRG E.TRG = PW SNR Changing each setting in PW SNR modeMode = E.TRG E.TRG = PW SR Changing each setting in PW SR modeMode = E.TRG E.TRG = RR Changing each setting in RR modeChanging each setting in Gain Changing the gain in Manu modeWHT BAL White balance Changing the manual shading correction setting Changing the shading correction modeChanging master pedestal Changing R pedestalSync Adjusting horizontal phaseOption Data UP, Down Menu UP, DownExternal sync signal polarity Setting to factory setting statusShutter mode HD input VD input External SyncUsing the unit with external sync signal Setting by the frameSetting by 1H Horizontal phase adjustment1 Pulse Trigger SYNC-NON Reset Picture Output Timing 1P SNR 1 Pulse Trigger Sync Non ResetEXT Trig External trigger Fval Lval DvalInternal VD*3 1 Pulse Trigger SYNC-RESET Picture Output Timing 1P SR 1 Pulse Trigger Sync ResetPW SNR Pulse width trigger SYNC-NON Reset About 7 ∝s 1 Pulse Width Trigger SYNC-RESET Picture Output Timing PW SR Pulse width trigger SYNC-RESETRR Reset restart Input Timing Chart ExampleLong Term Exposure Partial Read When Partial Scanning Mode is onPartial Scanning OFF All pixels scanning Partial Scanning onInput Output Signal Specificatoins CCD Output Waveform Timing Chart Horizontal Output Waveform Timing ChartVertical Output Waveform Timing Chart RGB, 3CCD SpecificationsExternal Appearance Diagram Before Making a Service CallSymptom Items to be checked Limited One 1 Year Warranty of Labor and Parts Step-by-step Procedures How to Obtain Warranty ServiceImaging Systems Division