AOP Setup & Configuration

4.When you select ON for backlighting timer, the AOP displays a backlighting time setting

screen.

Use and to set the timer period of inactivity (in seconds).

Press to confirm the setting and the AOP returns to the setup menu.

NOTE: Simultaneously press and at any time to display relevant help screens.

Screen Contrast

1.Use and to highlight the Screen Contrast option on the setup menu. Press to confirm the selection.

The AOP displays a contrast screen.

2.Use and to adjust the contrast level.

Press to confirm the selection and the AOP returns to the setup menu.

Large Number Display

You can configure the AOP for a large-number display of the SED2 VFD frequency.

In the Large Number Display mode, you can temporarily switch to normal display mode (4 lines) with the keys and . After an adjustable time delay, the display switches back to large characters.

Use the following procedure to activate the large number display:

1.Use and to highlight the Large Numbers option on the setup menu. Press to confirm the selection. The AOP displays a large number screen.

2.Use and to select either an OFF or ON large number display. Press to confirm the selection.

NOTE: When you select OFF for no large number display, the AOP returns to the setup menu.

3.Select a requested delay time (4 through 250 seconds).

Press to confirm the selection and to return to the main menu.

Cursor Type

1.Use and to highlight the Cursor Type option on the setup menu. Press to confirm the selection.

The AOP displays a cursor type screen.

Siemens Building Technologies, Inc.

25

Image 33
Contents SED2 Advanced Operator Panel AOP Page Rev , September SED2 AOP Operating InstructionsPage Service Statement European Machinery Directive European Low Voltage DirectiveEuropean EMC Directive Underwriters LaboratoriesTable of Contents AOP Faults & Warnings AOP Setup & ConfigurationManual Organization How to Use this ManualNotation Symbol Meaning Where To Send CommentsManual Notations Reference DocumentsAOP Menu Structure AOP OverviewMain Menu Local and Master Modes Local 1 DriveKey Function Functional Description Key FunctionsAOP Overview Power-on and Initialization AOP Start-Up & InitializationImportant Notes Start Help Language SelectionMemory Limitation To Delete a LanguageQuick Commissioning Menu ItemDescription AOP Start-Up & Initialization Stopped Running Fault Inhibit Single Drive Control Using the AOP Network Setup RS-485 with Panel Mounting KitAOP Applications Network Setup PC Mode Parameter Access Levels Editing ParametersEditing Conventional Parameters Editing Indexed Parameters TIP How to quickly change parameter values?AOP Stored Parameter Sets Editing AOP-Stored Parameter SetsEditing Internal AOP Parameter Set Parameter Upload Upread Upload/Download LimitationsParameter Parameter Download Wait RequestSED2 AOP Operating Instructions Selecting an Operating Mode Operating ModeAOP Operating Modes Operating in Local Mode Operating in Master Mode Individual Control of SED2 VFDIcon Description Communications Failure Operating in Master Mode Broadcast OperationDisplaying Drive Status Verifying Drive TypeTimer Function Setting the AOP TimerKey Timer Function AOP Setup & Configuration Setup MenuBacklighting Screen Contrast Large Number DisplayCursor Type User Defined Text Welcome TextSet Time/Date Parameter Set Names$51,1 AOP ResetFault Indication/Fault Screen AOP Faults & WarningsSimultaneous Faults and Warnings Multiple FaultsSED2 VFD Fault/Warning Record P0947 Multiple WarningsSiemens Building Technologies, Inc Siemens Building Technologies AG Siemens Building Technologies, Inc