Liebert SERIES 300 UPS manual Control Wiring Diagram 40-50 kVA

Page 35

Figure 9 Control Wiring Diagram 40-50 kVA

Installation 29

Image 35
Contents Series 300 UPS Page Table of Contents Êïèïë ÊïéïìÊïéïë ÊïèïìÈïçïé ÈïçïìÈïçïë ÈïçïêLJXUHýé LJXUHýìLJXUHýë LJXUHýêPDLQWHQDQFHýRIý\RXUý6HULHVýêííý836ýDQGýEDWWHULHVï $ $51,1 Important Safety InstructionsPage +$/ý92/7$*6ý,67ý,7+,1ý7+,6ý48,3017ý85,1*ý $87,21PRVWýVLJQLILFDQWýFDXVHýRIýVWDUWðXSýSUREOHPVï $51,1Definitions Static Bypass Line Static Transfer SwitchMaintenance Bypass Line External Maintenance Bypass CabinetThrough the UPS Module Modes of OperationVXSSRUWLQJýWKHýORDGï Safety PrecautionsHFHVVýPRLVWXUHñýRUýGHEULVï Site Planning Data, Series 300 UPS, 10 to 50 kVA Site Planning Data, Series 300 UPS, 65 to 125 kVA $ &$87,21 UPS InstallationInstallation Considerations YHUWLFDOýDWýDOOýWLPHVï Unloading and External InspectionInternal Inspection of the UPS System Equipment LocationBattery Safety Precautions Battery InstallationIHHWýDQGýUHPRYHýVXSSRUWLQJýGHYLFHï Matching Battery CabinetsNon-Standard Batteries Power and Control Wiring Electrical WiringUPS Wire Size Guidelines UHVXOWï Battery WiringWKHý%DWWHU\ý&DELQHWýWRýWKHýDVVRFLDWHGý836ï ÕZKHQýQHHGHGôïCopper Aluminum or Copper-Clad Aluminum Connection Type / Wire Size Range Wiring Inspection Wiring ConnectionsSingle Line Diagram 10-125 kVA Installation UPS Cabinet Installation Diagram 10-30 kVA UPS Cabinet Installation Diagram 40-50 kVA UPS Cabinet Installation Diagram 65-125 kVA Battery Cabinet Installation Diagram 22-inch Frame Battery Cabinet Installation Diagram 36-inch Frame Battery Cabinet Installation Diagram 36-inch Frame Control Wiring Diagram 10-30 kVA Control Wiring Diagram 40-50 kVA Control Wiring Diagram 65-125 kVA Field Wiring Terminations Field Wiring Terminations Digital Display Screen Operator Controls and IndicatorsBlock Diagram of the Series 300 UPS Selection Pads Power Status DiagramRSHUDWLRQï Rotary SwitchAdvisory Display \SDVVý/LQHïMenu Selection Arrangement Display Screen MenuLoad on UPS Load XXX% Default Screen MessagesOn Maintenance Normal OperationTime Remaining XX Minutes Load on Static SwitchFault System Shutdown UPS on BatteryOperator Response to an Alarm Alarm MessagesUPS Response to an Alarm 60.0 Hz Load XXX% a Phase XXX kVA B Phase XXX kVA C Phase XXX kVASystem Status Screens Voltage 410 Amps ChargingOutput Voltage Rating Press Review System Options ConfigurationDeutsche English Espanol Francais Italia Press To set RatingPress To set Low BatteryNominal Input / OutputTime and Date Auto BatteryPress To view or set MON APR 15ODWHUï Auto RestartLamp Test Alarm History Press To accessAlarm History Start-Up from Position Start-Up ProcedureStart-Up Press Button To start system PowerTesting charger Testing inverterPosition Rotary switch toTesting battery Testing staticWKHýORDGïý7KHýIROORZLQJýGHIDXOWýPHVVDJHýZLOOýDSSHDUãý Testing InputSynchronization SRZHUýWRýWKHýFULWLFDOýORDGïIýWKHýV\VWHPýGHWHFWVýDQýDEQRUPDOýFRQGLWLRQýGXULQJýVWDUWðXSã Abnormal Conditions During Start-UpRLQJýVRýZLOOýFDXVHýDQýLPPHGLDWHýORVVýRIýSRZHUýWRýWKHýORDGï Improperly OperatedResponse to an Incorrect Start-Up Sequence FULWLFDOýORDGïNormal Operation Please turn ShutdownVXSSO\ýSRZHUýWRýWKHýLQYHUWHUýZKLFKýVXSSRUWVýWKHýORDGï Response to a Power FailureCalculating Time Remaining UPS ResponseOperator Response As Battery Time Approaches ZeroWKHýFULWLFDOýORDGýWKURXJKýWKHý0DLQWHQDQFHý%\SDVVý/LQHï On Static SwitchResponse to a UPS Failure $QýDXGLEOHýDODUPýZLOOýVRXQGïAlarm Messages UPS System Cooling Maintenance IýDQ\ýRIýWKHýDERYHýRFFXUã When To CallSteps To Take Periodic Restart of the UPS Preventive MaintenanceMaintaining an Operator’s Log Changing the Air FilterMaintaining the Battery 356211/ý48$/,,ý67ý548,6ý3285ý&785ý&6ý $957,660176ý3,&6ý6286ý$/,017$7,21ý65217ý/$,666ý6$16ý 3527&7,21ý85$17ý&6ý352&856ýª1757,1ïý81ýREVHUYpHVã Battery Voltage VDC Ìï HDUýIXOOýH\HýSURWHFWLRQýDQGýSURWHFWLYHýFORWKLQJï PDQXDOïý $ &$87,21Training Liebert Customer Service and SupportMaintenance Agreements Professional Start-upFDQQRWýEHýLQVWDOOHGýVHSDUDWHO\ýIURPýWKHý836ýPRGXOHï Optional External Maintenance Bypass CabinetInstallation Location Considerations General127 5HIHUýWRýëïéïì ðý836ýLUHý6LHý*XLGHOLQHVï Electrical Wiring7KHýWKUHHý5RWDU\ý6ZLWFKýSRVLWLRQVýDUHã Operation Control Rotary SwitchGLWLRQýRFFXUVï FRQGLWLRQýKDVýEHHQýFRUUHFWHGïShutdown to Maintenance Position RSWLRQýZKHQýDýUHPRWHýVWDWXVýSDQHOýRSWLRQýLVýSURYLGHGï Optional Slim-Line DistributionOptional Remote Status Panel Optional Remote Contact BoardOptional RS-232 Interface Port Using a Terminal as a Remote StationKey Description Remote Front Panel Terminal ModeRemote Load Control Setting the PasswordPassword Emerson Standard Protocol ESPPHQWDWLRQýVXSSOLHGýVHSDUDWHO\ï Using an Snmp Adapter OptionalWXUQýWKHýORDGýRQýRUýRIIýDWýZLOOï Optional Internal Modem Modem Mode OFFOutgoing Calls Using the ModemIncoming Calls 000*000*000**?# Pager Disabled91000-000-0000 VLEOHýZKHQýLWýFDOOVýDýSDJHUýVHUYLFHýQXPEHUï Calling a ModemDQýHYHQWýRFFXUVïý WLRQã Editing the Phone NumbersÜýíýìýëýêýéýèýçýæýåýäýðýõýôýñýúýý5ý7ý3ý#ýóýâý Last Attempts Testing the Dial-Out SetupSetting the Data Rate Dial Test OFFÌëííï Optional IBM AS/400 Signal InterfaceOptional SiteScan /Sitemaster Interface \RXýDUHýSUHSDUHGïOptional Contact Isolator Board Optional System/38 Power Warning SignalOptional Battery Circuit Breaker Optional DC Ground Fault AlarmOptional IBM AS/400 Multi-Interface System Optional Multi-Computer Interface SystemOptional Maintenance Bypass Cabinet System Options Optional Slim-Line Distribution Optional Slim-Line Distribution Optional Remote Status Panel Optional Remote Contact Board Optional IBM AS/400 Signal Interface System Options Optional Battery Circuit Breaker 10-75 kVA Optional Battery Circuit Breaker 100-125 kVA Optional Computer Interface System Optional Multi-Computer Interface System Optional IBM AS/400 Multi-Interface System AC Inputs to UPS Electrical SpecificationsDXOWý&OHDULQJãý 6XEýF\FOHýFXUUHQWýRIýDWýOHDVWýêííø AC Output. UPS Inverter7HPSHUDWXUHý5DQJHã ‡ 2SHUDWLQJã Environmental SpecificationsMechanical Specifications RatingsDWWHU\ý7\SHãý6HDOHGñýOHDGðDFLGñýLQýPDWFKLQJýFDELQHWýý BatterySpecifications 5HYLVHGãý-XO\ýìääæ SDFNDJHïXVWRPHUý5HVSRQVHý&HQWHUï