AMT Datasouth 5106 manual Changing the Direction of the Take-up Roller

Page 17

7.Confirm the original position of the thermal head again. Then tighten two hexagon bolts to fix thermal head to bracket EA.

Note:

Over-tightening hexagon bolt may cause the screw thread to break.

8.Clean the elements of the thermal head by using a soft cloth with isopropyl alcohol. Test print a label. If the printing result is uneven or contrast is unacceptable, check the original fixing position of the thermal head at first and adjust the thermal head position as necessary.

4.2Changing the Direction of the Take-up Roller

1.Power off the printer.

2.Fully extend the take-up roller.

3.Remove the take-up roller motor cover.

4.Switch the locations of the red and white wires on the motor side of the connector.

5.Reinstall the cover.

9

Image 17
Contents CodeWriter Technical Reference AMT Datasouth Corp AMT Datasouth CodeWriter 5106 Disclaimer of Warranties Copyright Notice Page Page Table of Figures Page General Information FeaturesRibbon Specifications 5106 Overall DimensionsSelection of Media Output Mode Initial SetupAssembly and Setup Procedure MODE/MENU Parameter Setting ModeParameter Tree Version Loading INK Ribbon and Label Roll ∙ If outside winding label roll is used Thermal Head Replacement AdjustmentsChanging the Direction of the Take-up Roller Thermal Head Block Thermal Head PositioningMechanical Adjustment Mechanical Adjustments to the Thermal HeadPage Page Page Page Page Ribbon Ribbon AdjustmentPage Wrinkle On Ribbon Running ConditionPage Sensor Type and Functions SensorsSensitivity Adjustment Name Electrical Circuitry External Connector and PIN Assignments Usage and Adjusted By Voltage Check and AdjustmentMain PCB Board Voltage Adjusted ByTAKE-UP Motor Connectors