AMT Datasouth 5106 manual Voltage Check and Adjustment, Usage and Adjusted By

Page 34

11.0 VOLTAGE CHECK AND ADJUSTMENT

Check Terminal

 

Switch Setting and

Usage and Adjusted By

 

 

Typ. Voltage

 

V1

W

H:20.0 +/- 0.5

For Take-Up Motor

 

 

L: 18.0

+/- 0.5

By VR1 on Motor Control

 

 

 

 

Board (TPB-2177)

 

 

 

 

 

V2

R

H: 20.0

+/- 0.5

For Ribbon Motor

 

 

L: 17.6

+/- 0.5

By VR2 on Motor Control

 

 

 

 

Board (TPB-2177)

 

 

 

 

 

NOTES:

 

 

 

 

W switch for Take-Up Motor has to be set to ‘H’ side whenever Presentation Mode is selected. In other modes, W switch should be set to ‘L’ side.

R switch for Ribbon Motor is set to ‘L’ as usual.

26

Image 34
Contents CodeWriter Technical Reference AMT Datasouth Corp AMT Datasouth CodeWriter 5106 Disclaimer of Warranties Copyright Notice Page Page Table of Figures Page Features General Information5106 Overall Dimensions Ribbon SpecificationsAssembly and Setup Procedure Initial SetupSelection of Media Output Mode Parameter Setting Mode MODE/MENUParameter Tree Version Loading INK Ribbon and Label Roll ∙ If outside winding label roll is used Adjustments Thermal Head ReplacementChanging the Direction of the Take-up Roller Thermal Head Positioning Thermal Head BlockMechanical Adjustments to the Thermal Head Mechanical AdjustmentPage Page Page Page Page Ribbon Adjustment RibbonPage Running Condition Wrinkle On RibbonPage Sensors Sensor Type and FunctionsSensitivity Adjustment Name Electrical Circuitry External Connector and PIN Assignments Voltage Check and Adjustment Usage and Adjusted ByVoltage Adjusted By Main PCB BoardTAKE-UP Motor Connectors