AMT Datasouth 5106 manual Name

Page 31

NAME

ADJUSTMENT PROCEDURE (Message on Display)

Media Gap (Label Gap)

By volume B in media compartment.

 

Sensitivity range (1st).

 

With Gap, 70% or more.

 

With media (label), 35% or less

Black Line

SEE ABOVE NOTE BEFORE MAKING ADJUSTMENT

 

By volume B in the media compartment.

 

Sensitivity range (2nd)

 

When black paper or color except black, 70% or more

 

When black line, 35% or less

Ribbon

By VR1 on TPB-2170

 

Sensitivity range (Rib)

 

With no ribbon, 70% or more

 

With ribbon, 25% or less

Presentation (Strip)

By VR2 on TPB-2170.

 

Sensitivity range (Pre)

 

When media (label), 75% or more

 

When no media (label), 25% or less

Head-Up

No volume for sensitivity adjustment.

 

 

23

Image 31
Contents CodeWriter Technical Reference AMT Datasouth Corp AMT Datasouth CodeWriter 5106 Disclaimer of Warranties Copyright Notice Page Page Table of Figures Page General Information FeaturesRibbon Specifications 5106 Overall DimensionsAssembly and Setup Procedure Initial SetupSelection of Media Output Mode MODE/MENU Parameter Setting ModeParameter Tree Version Loading INK Ribbon and Label Roll ∙ If outside winding label roll is used Thermal Head Replacement AdjustmentsChanging the Direction of the Take-up Roller Thermal Head Block Thermal Head PositioningMechanical Adjustment Mechanical Adjustments to the Thermal HeadPage Page Page Page Page Ribbon Ribbon AdjustmentPage Wrinkle On Ribbon Running ConditionPage Sensor Type and Functions SensorsSensitivity Adjustment Name Electrical Circuitry External Connector and PIN Assignments Usage and Adjusted By Voltage Check and AdjustmentMain PCB Board Voltage Adjusted ByTAKE-UP Motor Connectors