Asante Technologies 1012 manual Shown below, About Spanning Trees

Page 31

Installing the AsantéBridge 1012

3

Connect the MAU to the AsantéBridge external port as

shown below.

 

External Port

 

2A/250V Slow Blow Fuse

 

Replace Only With Fuse of Same Rating

RJ21

10 BASE-T PORTS

IN or OUT

BNC

AUI

3-IN-1 UPLINK

 

 

THROUGH

RS232

AMS LINK

END

PARTITION

UP=PC

Spare Fuse in Fuse Holder

DOWN=TERMINAL

TRAFFIC

 

 

Hub Port

 

Figure 1-10 Connecting to the External Port

4

Connect the remaining backbone cable to another MAU,

also with an AUI connector on the other end.

 

Alternatively, you can prepare the cable with a male BNC

 

connector.

5

Connect the second MAU to the AsantéBridge hub port,

which is actually the hub 3in1 port. See Figure 1-10 on

 

page 1-19 for the location.

6

Power up the AsantéBridge.

The unit automatically begins bridging between the two

 

segments, building a dynamic forwarding address table as

 

each device on both segments transmits.You do not need

 

to configure, program, or modify the AsantéBridge in any

 

way.All operation is completely automatic.

About Spanning Trees

Although this simple installation procedure does not describe a spanning tree configuration, there is no difference. If you install the AsantéBridge in parallel with another bridge implementing the IEEE 802.1d spanning tree algorithm, it will automatically begin to participate in the spanning tree algorithm.You do not need to take any special steps to prepare or configure the bridge.

Page 1-19

Image 31
Contents AsantéBridge Users’ Guide Trademarks Tell Us What You Think Page Table of Contents AsantéBridge 1012 Local Management Configuring a Redundant LinkSetting Up Out-of-Band Links Connecting a VT100 Terminal Default SettingsList of Figures Figure C-4 Crossover RJ-45 Cable page C-4 Introduction Manual About ThisIntroduction Intended Audience Intended Audience Conventions Used In This ManualTechnical Support Tell Us What You ThinkQuick Start Start Before YouQuick Start Introducing the AsantéBridge Introducing AsantéBridgeBridging Between Two Segments Snmp AsantéBridge FeaturesAsantéBridge Quick ViewFront Panel Quick View Bridge Hub Port Status LEDs RJ45 Port ConnectorsBridge External Port Status LED Bridge Spanning Tree Status LEDsAsantéBridge 1012 Rear Panel RJ21 Port Connector3in1 Port Bridge External Port Collision LED Through/End DIP SwitchBridge External Port AUI Bridge External Port Link/Receive LEDFan PC/Terminal DIP SwitchAC Power Connector On/Off SwitchFlashing Interpreting LEDsPreparing for the Installation Installing AsantéBridge 1012Installing the AsantéBridge Tools Basic Installation ProceduresUnpacking the AsantéBridge Asante´Hub Positioning the AsantéBridgeRack-mounting the AsantéBridge Page Dividing the Network into Segments Connecting Two Segments to the AsantéBridgeAbout Spanning Trees Shown belowUsing the front panel RJ45 ports Connecting Devices to the AsantéBridgeWhat You Need Configuration Options Using the rear panel RJ21 connectorQuick Start Connecting to the Network Before You Start Connecting to the NetworkAbout Bridging About BridgingBridging between segments Simple Transparent BridgeAbout Bridging Like this Spanning TreeRedundant bridging Connecting to the BNC Port Using the 3in1 PortInterconnecting Hubs on Thin Ethernet Backbone Using the 3in1 PortInterconnecting Using Foirl Fiber Optic Inter-Repeater Link Connecting to the AUI PortInterconnecting to Thick Ethernet Backbone Connecting to the RJ45 in and Out Ports Connecting an In-Band Daisychaining Checking the Link Configuring a Redundant Link10BaseT An Example Configuration Configuring a Redundant LinkIf a Link Goes Down to the Main Hub If the Main Hub Goes DownSetting Up Out-of-Band Links Setting Up Out-of-Band LinksInterconnecting Hubs 10 Connecting the Asanté Management Station for Out-of-Band Distance Restrictions Recommended MethodPC/Terminal Switch Configuring Hub DIP SwitchesThrough/End Switch Connecting a VT100 Terminal Connecting a VT100 TerminalLists the factory default settings Default SettingsAsantéBridge 1012 Local Management AsantéBridge 1012 Local Management These functions, use the following flow chartBridge Diagnostics Bridge DiagnosticsLocal Management Main Menu Local ManagementLocal Management Menu System Local Management Help Window General Help MenuConfiguration Menu System Accessing the Configuration Menu systemConfiguration Menu System Reset System item is a command. Selecting this item Information Menu SystemPassword Menu Password MenuParameters Menu System Snmp AgentBridge Snmp agent menu has the following four submenus TCP/IP Parameters Menu TCP/IP Parameters MenuSoftware Update Menu Software Update MenuAbout the Software Update function Configuration Menu System Menu without taking any action 10 System Update Status WindowConfiguration Menu System 11 Snmp Trap Receiver Table Snmp Trap Receiver Table12 Snmp Community Name Table Snmp Community Name TableThis table allows you to control access to Snmp MIB objects 13 Out-of-Band Parameters Menu Out-of-Band Parameters MenuEnter control-z to return to the Configuration Menu 14 Bridge Parameters Menu Bridge Parameters Menu System15 Spanning Tree Bridge Parameters Menu Spanning Tree Bridge Parameters MenuActivity.To update the window, enter control-r 16 Spanning Tree Port Setting Menu Spanning Tree Port Setting MenuAbout Forwarding Bridge Forwarding TableExit returns you to the Bridge Parameters Menu About dynamic and static table entries Alphabetic portion of the field defines the type of entryAsantéBridge 1012 Local Management 18 Editing the Forwarding Table Using the Edit Function19 Searching for an Address Using the Search FunctionAbout the Filtering Table Bridge Filtering Table20 Bridge Filtering Table Configuration Menu System 21 Resetting the Bridge Resetting the BridgeMenu 22 Bridge Statistics Statistics Menu SystemSupport for Pre 10BaseT Devices Appendix a Support for Pre 10BaseT Devices Technical Specifications Appendix B Technical Specifications B-3 B-4 Pinouts and Cable Specifications RJ-45 to RJ-21 Pinouts Amphenol to Modular Jack Appendix C Pinouts and Cable SpecificationsC-3 RJ-45 to RJ-45 Crossover Cable RJ-45 Modular Jack to Wall Jack PinoutsTable C-1 AUI Pinouts AUI DB-15 PinoutsC-6 AsantéBridge 1012 Index LED Numerics Manual P/N