Asante Technologies 1012 manual Default Settings, Lists the factory default settings

Page 56

Chapter 2 — Connecting to the Network

Default Settings

Table 2-2 lists the factory default settings.

Table 2-2 AsantéHub 1012 Factory Default Settings

Default

To Modify

 

 

All RJ45/RJ21 ports have Link Integrity testing

If you are using AsantéHub with a pre-10BaseT device,

enabled. Jumper JP8 is set OUT to enable

disable Link Integrity. (You will not be able to obtain link

Link Integrity testing on the 3-in-1 Uplink

integrity status from disabled ports.)

 

To disable Link Integrity testing over the 3-in-1 Uplink

 

set JP8 IN.

 

To disable Link Integrity testing over device links, use

 

the Port Control window in AsantéView.

Primary link selection follows autoselection

To force primary link selection to AUI, set jumper JP7

sequence. Jumper JP7 is set OUT.

IN.

All front panel ports (RJ45) are hardware-con-

To connect two hubs using front panel ports, use a

figured IN and cannot be modified.

crossover RJ45 cable (see Appendix C for pinouts).

Port Control:

Reconfigure using Port Control window in AsantéView.

Link Test enabled

 

Jabber detection enabled

 

Polarity Correction enabled

 

Receive Threshold not reduced

 

Bridge/Hub Port (AMS Link): 9600 bps, 8 data

Cannot be modified.

bits, 1 stop bit, no parity

 

Local Management Port (RS-232): 9600 bps, 8

Configure using VT100 or PC/Macintosh running VT100

data bits, 1 stop bit, no parity. (Communica-

emulation software.

tion rate between hub and PC or modem on

 

RS-232 port.)*

 

Node Age time: 60 seconds. (Storage period

Configure in AsantéView.

for hub statistics.)

 

SYS contact: none

Configure in AsantéView or with Local Management

SNMP Read Community string: public

Configure in AsantéView or with Local Management

SNMP Write Community String: private

Configure in AsantéView or with Local Management

Modem Dial string: none

Configure in AsantéView or with Local Management

*Communication with a terminal is fixed at 9600 bps.

Page 2-22

Image 56
Contents AsantéBridge Users’ Guide Trademarks Tell Us What You Think Page Table of Contents Configuring a Redundant Link Setting Up Out-of-Band LinksConnecting a VT100 Terminal Default Settings AsantéBridge 1012 Local ManagementList of Figures Figure C-4 Crossover RJ-45 Cable page C-4 Introduction Introduction About ThisManual Intended Audience Conventions Used In This Manual Intended AudienceTell Us What You Think Technical SupportQuick Start Quick Start Before YouStart Introducing AsantéBridge Introducing the AsantéBridgeBridging Between Two Segments AsantéBridge Features SnmpFront Panel Quick ViewAsantéBridge Quick View RJ45 Port Connectors Bridge External Port Status LEDBridge Spanning Tree Status LEDs Bridge Hub Port Status LEDs3in1 Port RJ21 Port ConnectorAsantéBridge 1012 Rear Panel Through/End DIP Switch Bridge External Port AUIBridge External Port Link/Receive LED Bridge External Port Collision LEDPC/Terminal DIP Switch AC Power ConnectorOn/Off Switch FanInterpreting LEDs FlashingInstalling the AsantéBridge Installing AsantéBridge 1012Preparing for the Installation Unpacking the AsantéBridge Basic Installation ProceduresTools Positioning the AsantéBridge Asante´HubRack-mounting the AsantéBridge Page Connecting Two Segments to the AsantéBridge Dividing the Network into SegmentsShown below About Spanning TreesWhat You Need Connecting Devices to the AsantéBridgeUsing the front panel RJ45 ports Using the rear panel RJ21 connector Configuration OptionsQuick Start Connecting to the Network Connecting to the Network Before You StartAbout Bridging About BridgingSimple Transparent Bridge Bridging between segmentsAbout Bridging Spanning Tree Like thisRedundant bridging Using the 3in1 Port Connecting to the BNC PortUsing the 3in1 Port Interconnecting Hubs on Thin Ethernet BackboneConnecting to the AUI Port Interconnecting Using Foirl Fiber Optic Inter-Repeater LinkInterconnecting to Thick Ethernet Backbone Connecting to the RJ45 in and Out Ports Connecting an In-Band Daisychaining 10BaseT Configuring a Redundant LinkChecking the Link Configuring a Redundant Link An Example ConfigurationIf the Main Hub Goes Down If a Link Goes Down to the Main HubInterconnecting Hubs Setting Up Out-of-Band LinksSetting Up Out-of-Band Links 10 Connecting the Asanté Management Station for Out-of-Band Recommended Method Distance RestrictionsThrough/End Switch Configuring Hub DIP SwitchesPC/Terminal Switch Connecting a VT100 Terminal Connecting a VT100 TerminalDefault Settings Lists the factory default settingsAsantéBridge 1012 Local Management These functions, use the following flow chart AsantéBridge 1012 Local ManagementBridge Diagnostics Bridge DiagnosticsLocal Management Local Management Main MenuLocal Management Menu System General Help Menu Local Management Help WindowConfiguration Menu System Accessing the Configuration Menu systemConfiguration Menu System Reset System item is a command. Selecting this item System Information MenuPassword Menu Password MenuBridge Snmp agent menu has the following four submenus Snmp AgentParameters Menu System TCP/IP Parameters Menu TCP/IP Parameters MenuSoftware Update Menu Software Update MenuAbout the Software Update function Configuration Menu System 10 System Update Status Window Menu without taking any actionConfiguration Menu System Snmp Trap Receiver Table 11 Snmp Trap Receiver TableSnmp Community Name Table 12 Snmp Community Name TableThis table allows you to control access to Snmp MIB objects Out-of-Band Parameters Menu 13 Out-of-Band Parameters MenuEnter control-z to return to the Configuration Menu Bridge Parameters Menu System 14 Bridge Parameters MenuSpanning Tree Bridge Parameters Menu 15 Spanning Tree Bridge Parameters MenuActivity.To update the window, enter control-r Spanning Tree Port Setting Menu 16 Spanning Tree Port Setting MenuBridge Forwarding Table About ForwardingExit returns you to the Bridge Parameters Menu Alphabetic portion of the field defines the type of entry About dynamic and static table entriesAsantéBridge 1012 Local Management Using the Edit Function 18 Editing the Forwarding TableUsing the Search Function 19 Searching for an AddressBridge Filtering Table About the Filtering Table20 Bridge Filtering Table Configuration Menu System Resetting the Bridge 21 Resetting the BridgeMenu Statistics Menu System 22 Bridge StatisticsSupport for Pre 10BaseT Devices Appendix a Support for Pre 10BaseT Devices Technical Specifications Appendix B Technical Specifications B-3 B-4 Pinouts and Cable Specifications Appendix C Pinouts and Cable Specifications RJ-45 to RJ-21 Pinouts Amphenol to Modular JackC-3 RJ-45 Modular Jack to Wall Jack Pinouts RJ-45 to RJ-45 Crossover CableAUI DB-15 Pinouts Table C-1 AUI PinoutsC-6 AsantéBridge 1012 Index LED Numerics Manual P/N