Adder Technology 5000 manual Global user access via VNC viewer, To access via the VNC viewer

Page 39

Global user access via VNC viewer

The VNC viewer is a compact application that runs on your IP-connected ‘global’ system and allows you to view and use the AdderView CATxIP 5000 and its host computer(s). VNC viewer is readily available from a number of different sources:

from the AdderView CATxIP 5000 installation CD

from the AdderView CATxIP 5000 itself

from the RealVNC website

To access via the VNC viewer

1Locate and select the VNC viewer icon

A connection details dialog will be displayed:

Enter the AdderView CATxIP 5000 address here and click OK

If required, select the encryption mode - MORE [+]

Options button

Provides a range of viewer and connection settings - MORE [+]

2In the ‘Server:’ entry, type the address of the AdderView CATxIP 5000 as follows:

v.w.x.y

where v.w.x.y is the IP network address, for example 192.168.0.3

If you have been asked to also enter a port number.

3Click the OK button. Depending on the options selected, you may need to confirm certain items. A connection attempt will be made and if successful, an authentication dialog will be displayed:

4Enter your Username and Password. The viewer window should now open and show the current host computer. Note: If the Username entry is blanked out then only admin user account is currently defined and only a password is required.

Downloading VNC viewer from the AdderView CATxIP 5000

The AdderView CATxIP 5000 has the ability to distribute its own VNC viewer application.

To download the VNC viewer

1Open your Web browser.

2Enter the network address where the AdderView CATxIP 5000 is situated (in the form: http://192.168.0.3) and make the link.

3In the opening AdderView CATxIP 5000 screen, click the link that offers to download the secure VNC viewer ‘from the unit’.

4Save the download file (vncviewer.exe) to your system.

5Select and run the downloaded file and then connect to the AdderView CATxIP 5000 using the VNC viewer application.

IMPORTANT: During login, if you see a warning message similar to the one shown here, then stop and do not proceed.

This message is displayed if an AdderView CATxIP 5000 unit that your viewer has previously visited, has had a change of security keys. This is not uncommon if a unit is reset for some reason. However, it could also mean that your trusted unit is being spoofed and you may not be connecting to the system that you think you are.

Do not click the Yes button until you have checked with your administrator that the trusted AdderView CATxIP 5000 unit has been recently reset for some reason.

   



38

Image 39
Contents AdderView CATxIP Contents Further information Index Many computers CAM formatsCreating larger installations Cascade installationsEnterprise installations AdderView CATxIP 5000 features front and rear What’s in the box What you may additionally need  Mounting Single unit rack bracketsDouble unit rack brackets    ConnectionsFrom video monitor From USB keyboard and mouse Local userTo connect the local user port AdderView CATxIP Rear panelGlobal users IP network port To connect the IP network port for global usersAdderView CATxIP Front panel To connect a computer system Computer system via CAMPower in connection To connect the power supplyOutput lead from Power adapter Power control port To connect and address the switch boxesSwitch Multiple video head connections Remote switching control Host computer port/channelCable from serial Control device Overall initial configuration ConfigurationInitial configuration Security Main menuMenu layout HotkeysRegistering users and host computers General security and configuration stepsTo enable general security To set an Admin passwordTo clear a password and restore factory default settings What to do if the Admin password has been forgottenClearing IP access control What is IP access control?To clear IP access control To configure the unit from a global user location Full configuration by global userEncryption settings AdderView CATxIP 5000 encryption settingsViewer encryption settings Positioning AdderView CATxIP 5000 in the network Networking issuesFirewall/router address Port settingsPlacing AdderView CATxIP 5000 behind a router or firewall AddressingDNS addressing To discover a DHCP-allocated IP addressPlacing AdderView CATxIP 5000 alongside the firewall Ensuring sufficient securityPorts To control two or more ports simultaneously Power switching configurationPower control sequences To configure the power sequences for each host computerUpgrading AdderView CATxIP 5000 models Recovering from a failed upgradeTo upgrade AdderView CATxIP 5000 models To invoke backup/recovery modeFront panel indicators Accessing the AdderView CATxIPSelecting a computer Local user accessSelect Host menu here you can select computers by name To select a computer using the Select Host menuWhen choosing Standard hotkeysLogging in and out Show All UsersTo enable/disable the confirmation box Confirmation status boxUser preferences and functions Orange dot indicators in the Select Host menu Global user access What will I see when I first login?How do multiple users coexist? Options button Global user access via VNC viewerTo access via the VNC viewer To download the VNC viewerTo access via your web browser Global user access via web browserUsing the viewer window When using the viewer windowMenu bar To select a host ConfigureMouse pointers Host selectionRe-synchronise mouse Access mode shared/privatePower switching Auto calibrateControls Keyboard Control Enable Sun TranslationWhen entering codes Video SettingsScreen contains only host system information Using automatic configurationsIncreased by 50% when a slow link is detected Setting the Threshold manuallyReduced Blanking Advanced Video SettingsShow All Users Custom Video ModesVNC hotkey selection Viewer encryption settings If you need to enter a port numberSupported web browsers US +1 888 275 TroubleshootingWhen logging on using VNC viewer, I cannot enter a username Getting assistanceTo access the local setup menus Appendix 1 Local setup menusFunctions Power ControlRestore Standard Mouse Restore IntellimouseScreen Saver Settings Blank, Moving LogoSettings Disabled, Enabled User PreferencesOSD Dwell Time Mouse SwitchingUser Timeout Global PreferencesSetup Options Logon SecurityAuto Logout IP address, net mask, VNC port, etc ConfigurationIP admin password, encryption settings, etc Completely resets the AdderView CATxIP 5000 unitUnit Configuration Network Configuration Options Port Serial ConfigurationSettings Power Control, Sync Units Settings 1200, 2400, 4800, 9600, 19200, 38400, 57600To reset the AdderView CATxIP 5000 configuration Reset ConfigurationAppendix 2 Configuration pages via viewer To access the remote configuration pagesMain configuration Logged on users User accounts Unit configuration Advanced unit configuration Time & date configuration IP Gateway Network configurationIP Access Control IP Network MaskTo edit/remove access control entries Setting IP access controlTo define a new IP access control entry To reorder access control entriesSerial port configuration Options Port UseBaud Rate Sort Host configurationErase Host Configuration Add entry for unrecognised hostFor further details To get here Logging and statusTo copy and paste the log Syslog Server IP AddressLdap configuration Preferred encoding Appendix 3 VNC viewer connection optionsColour/Encoding Auto selectCustomise Enable all inputsDisable all inputs view-only mode InputsMisc Custom Size ScalingNo Scaling Scale to Window SizeLoad / Save Defaults ReloadDefaults Save IdentitiesAppendix 4 VNC viewer window options Appendix 5 Browser viewer options Encoding and colour levelSecurity Appendix 6 Addresses, masks and ports IP addressesNet masks Binary octet after Net masks the binary explanationOperation with net mask Binary equivalentAddress ranges Calculating the mask for IP access controlSingle locations All locationsPorts Security issues with portsAppendix 7 Cascading multiple units See alsoCascade tree Connecting units in cascade Tips for successful cascadingTo connect units in cascade Addressing computers in a cascade Using cascaded computersMulti-head synchronisation cable Appendix 8 Cable and connector specificationsAdderView CATxIP 5000 to power switch cable Power switch to power switch daisy chain cableAppendix 9 Hotkey sequence codes Permissible key pressesCreating macro sequences Appendix 10 Supported video modes Warranty Safety informationGeneral Public License Linux End user licence agreement Canadian Department of Communications RFI statement Radio Frequency EnergyEuropean EMC directive 89/336/EEC FCC Compliance Statement United StatesHoe Huat Industrial Building Index Options port Upgrade failure Connection Baud rate