Adder Technology manual AdderView CATxIP 5000 features front and rear

Page 7

AdderView CATxIP 5000 features - front and rear

The AdderView CATxIP 5000 units pack a great deal of functionality into a compact space. It occupies half of a single 1U rack space and presents most of its connectors at the rear face. The smart front face features the network port and the operation indicators.

Options port

This RS232 serial port can separately support the following functions:

Power switching - can be configured to control multiple power switching devices.

Remote control switching - commands can be received that will change the channel, as necessary.

Synchronisation - allows the actions of two or more AdderView CATxIP 5000 switches to be synchronised so that multiple computers/video screens can be switched and accessed.

LOC REM VNC 100 LNK PWR

 

 

IP network port

 

 

 

 

 

 

 

 

 

 

The port by which global users are linked to the

 

 

 

 

 

AdderView CATxIP 5000 unit. This intelligent

 

 

 

 

www.adder.com

Ethernet port can automatically sense whether

 

 

 

 

 

 

 

 

 

 

it is attached to a 10Mb or 100Mb network.

 

 

 

 

 

 

Indicators

These six indicators clearly show the key aspects of operation:

LOC Keyboard or mouse data are being received from the local console.

REM Keyboard or mouse data are being received from the remote console.

VNC Indicates that a global user is connected and active.

100 Indicates the Ethernet network speed (10/100Mbs).

LNK Indicates that a network link is present.

PWR Indicates that power is present.

   

 

 

16

15

14

13

8

7

6

5

ONLY

 

 

OPTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USE

 

 

 

 

 

 

 

 

 

 

Power input

 

 

 

 

 

 

 

 

 

INDOOR

The power supply

5V

12

11

10

9

4

3

2

1

connects here.

4.0A

 

 

 

COMPUTER CONNECTIONS

 

 

COMPUTER CONNECTIONS

 

 



Local user port

Connect a USB keyboard and mouse, plus a video monitor to these connectors. These allow you to perform the initial configuration of the AdderView CATxIP 5000. Additionally, you can use these to locally control the connected computer(s).

Computer ports

Each computer connects to one of these ports via standard category 5, 5e or 6 cabling. At the other end of the cabling a CAM (Computer Access Module) is used to provide the necessary keyboard, video and mouse connections.



Image 7
Contents AdderView CATxIP Contents Further information Index Many computers CAM formatsCascade installations Creating larger installationsEnterprise installations AdderView CATxIP 5000 features front and rear What you may additionally need What’s in the box  Single unit rack brackets MountingDouble unit rack brackets    ConnectionsFrom video monitor From USB keyboard and mouse Local userTo connect the local user port AdderView CATxIP Rear panelTo connect the IP network port for global users Global users IP network portAdderView CATxIP Front panel To connect a computer system Computer system via CAMTo connect the power supply Power in connectionOutput lead from Power adapter To connect and address the switch boxes Power control portSwitch Multiple video head connections Host computer port/channel Remote switching controlCable from serial Control device Overall initial configuration ConfigurationInitial configuration Security Main menuMenu layout HotkeysRegistering users and host computers General security and configuration stepsTo enable general security To set an Admin passwordTo clear a password and restore factory default settings What to do if the Admin password has been forgottenWhat is IP access control? Clearing IP access controlTo clear IP access control To configure the unit from a global user location Full configuration by global userAdderView CATxIP 5000 encryption settings Encryption settingsViewer encryption settings Positioning AdderView CATxIP 5000 in the network Networking issuesFirewall/router address Port settingsPlacing AdderView CATxIP 5000 behind a router or firewall AddressingDNS addressing To discover a DHCP-allocated IP addressEnsuring sufficient security Placing AdderView CATxIP 5000 alongside the firewallPorts To control two or more ports simultaneously Power switching configurationPower control sequences To configure the power sequences for each host computerUpgrading AdderView CATxIP 5000 models Recovering from a failed upgradeTo upgrade AdderView CATxIP 5000 models To invoke backup/recovery modeFront panel indicators Accessing the AdderView CATxIPSelecting a computer Local user accessSelect Host menu here you can select computers by name To select a computer using the Select Host menuWhen choosing Standard hotkeysLogging in and out Show All UsersConfirmation status box To enable/disable the confirmation boxUser preferences and functions Orange dot indicators in the Select Host menu What will I see when I first login? Global user accessHow do multiple users coexist? Options button Global user access via VNC viewerTo access via the VNC viewer To download the VNC viewerTo access via your web browser Global user access via web browserWhen using the viewer window Using the viewer windowMenu bar To select a host ConfigureMouse pointers Host selectionRe-synchronise mouse Access mode shared/privatePower switching Auto calibrateControls Keyboard Control Enable Sun TranslationWhen entering codes Video SettingsScreen contains only host system information Using automatic configurationsIncreased by 50% when a slow link is detected Setting the Threshold manuallyReduced Blanking Advanced Video SettingsShow All Users Custom Video ModesVNC hotkey selection If you need to enter a port number Viewer encryption settingsSupported web browsers US +1 888 275 TroubleshootingWhen logging on using VNC viewer, I cannot enter a username Getting assistanceTo access the local setup menus Appendix 1 Local setup menusFunctions Power ControlRestore Standard Mouse Restore IntellimouseScreen Saver Settings Blank, Moving LogoSettings Disabled, Enabled User PreferencesOSD Dwell Time Mouse SwitchingUser Timeout Global PreferencesLogon Security Setup OptionsAuto Logout IP address, net mask, VNC port, etc ConfigurationIP admin password, encryption settings, etc Completely resets the AdderView CATxIP 5000 unitUnit Configuration Network Configuration Options Port Serial ConfigurationSettings Power Control, Sync Units Settings 1200, 2400, 4800, 9600, 19200, 38400, 57600To reset the AdderView CATxIP 5000 configuration Reset ConfigurationTo access the remote configuration pages Appendix 2 Configuration pages via viewerMain configuration Logged on users User accounts Unit configuration Advanced unit configuration Time & date configuration IP Gateway Network configurationIP Access Control IP Network MaskTo edit/remove access control entries Setting IP access controlTo define a new IP access control entry To reorder access control entriesOptions Port Use Serial port configurationBaud Rate Sort Host configurationErase Host Configuration Add entry for unrecognised hostFor further details To get here Logging and statusTo copy and paste the log Syslog Server IP AddressLdap configuration Preferred encoding Appendix 3 VNC viewer connection optionsColour/Encoding Auto selectCustomise Enable all inputsDisable all inputs view-only mode InputsMisc Custom Size ScalingNo Scaling Scale to Window SizeLoad / Save Defaults ReloadDefaults Save IdentitiesAppendix 4 VNC viewer window options Encoding and colour level Appendix 5 Browser viewer optionsSecurity IP addresses Appendix 6 Addresses, masks and portsNet masks Binary octet after Net masks the binary explanationOperation with net mask Binary equivalentAddress ranges Calculating the mask for IP access controlSingle locations All locationsPorts Security issues with portsSee also Appendix 7 Cascading multiple unitsCascade tree Tips for successful cascading Connecting units in cascadeTo connect units in cascade Addressing computers in a cascade Using cascaded computersMulti-head synchronisation cable Appendix 8 Cable and connector specificationsAdderView CATxIP 5000 to power switch cable Power switch to power switch daisy chain cablePermissible key presses Appendix 9 Hotkey sequence codesCreating macro sequences Appendix 10 Supported video modes Safety information WarrantyGeneral Public License Linux End user licence agreement Canadian Department of Communications RFI statement Radio Frequency EnergyEuropean EMC directive 89/336/EEC FCC Compliance Statement United StatesHoe Huat Industrial Building Index Options port Upgrade failure Connection Baud rate