Warranty

Adder Technology Ltd warrants that this product shall be free from defects in workmanship and materials for a period of two years from the date of original purchase. If the product should fail to operate correctly in normal use during the warranty period, Adder will replace or repair it free of charge. No liability can be accepted for damage due to misuse or circumstances outside Adder’s control. Also Adder will not be responsible for any loss, damage or injury arising directly or indirectly from the use of this product. Adder’s total liability under the terms of this warranty shall in all circumstances be limited to the replacement value of this product.

If any difficulty is experienced in the installation or use of this product that you are unable to resolve, please contact your supplier.

Safety information

For use in dry, oil free indoor environments only.

Both the AdderView CATxIP 5000 and its power supply generate heat when in operation and will become warm to the touch. Do not enclose them or place them locations where air cannot circulate to cool the equipment. Do not operate the equipment in ambient temperatures exceeding 40 degrees Centigrade. Do not place the products in contact with equipment whose surface temperature exceeds 40 degrees Centigrade.

Warning - live parts contained within power adapter.

No user serviceable parts within power adapter - do not dismantle.

Plug the power adapter into a socket outlet close to the module that it is powering.

Replace the power adapter with a manufacturer approved type only.

Do not use the power adapter if the power adapter case becomes damaged, cracked or broken or if you suspect that it is not operating properly.

If you use a power extension cord with the AdderView CATxIP 5000, make sure the total ampere rating of the devices plugged into the extension cord does not exceed the cord’s ampere rating. Also, make sure that the total ampere rating of all the devices plugged into the wall outlet does not exceed the wall outlet’s ampere rating.

Do not attempt to service the AdderView CATxIP 5000 yourself.

Safety considerations when using power switches with AdderView CATxIP 5000

Follow the manufacturer’s instructions when setting up and using power switching products.

Always ensure that the total ampere rating of the devices plugged into the power switching product does not exceed the power switching product’s ampere rating. Also, make sure that the total ampere rating of all the devices plugged into the wall outlet does not exceed the wall outlet’s ampere rating.

General Public License (Linux)

The AdderView CATxIP 5000 runs an embedded version of the Linux operating system, licensed under the GNU General Public License. To obtain the source code for the open-source components of the system visit:

http://www.adventiq.com/products/ARQ3/gpl.html

   



88

Image 89
Contents AdderView CATxIP Contents Further information Index Many computers CAM formatsEnterprise installations Creating larger installationsCascade installations AdderView CATxIP 5000 features front and rear   What’s in the boxWhat you may additionally need Double unit rack brackets MountingSingle unit rack brackets    ConnectionsTo connect the local user port Local userAdderView CATxIP Rear panel From video monitor From USB keyboard and mouseAdderView CATxIP Front panel Global users IP network portTo connect the IP network port for global users To connect a computer system Computer system via CAMOutput lead from Power adapter Power in connectionTo connect the power supply Switch Power control portTo connect and address the switch boxes Multiple video head connections Cable from serial Control device Remote switching controlHost computer port/channel Overall initial configuration ConfigurationInitial configuration Menu layout Main menuHotkeys SecurityTo enable general security General security and configuration stepsTo set an Admin password Registering users and host computersTo clear a password and restore factory default settings What to do if the Admin password has been forgottenTo clear IP access control Clearing IP access controlWhat is IP access control? To configure the unit from a global user location Full configuration by global userViewer encryption settings Encryption settingsAdderView CATxIP 5000 encryption settings Positioning AdderView CATxIP 5000 in the network Networking issuesPlacing AdderView CATxIP 5000 behind a router or firewall Port settingsAddressing Firewall/router addressDNS addressing To discover a DHCP-allocated IP addressPorts Placing AdderView CATxIP 5000 alongside the firewallEnsuring sufficient security Power control sequences Power switching configurationTo configure the power sequences for each host computer To control two or more ports simultaneouslyTo upgrade AdderView CATxIP 5000 models Recovering from a failed upgradeTo invoke backup/recovery mode Upgrading AdderView CATxIP 5000 modelsFront panel indicators Accessing the AdderView CATxIPSelecting a computer Local user accessWhen choosing To select a computer using the Select Host menuStandard hotkeys Select Host menu here you can select computers by nameLogging in and out Show All UsersUser preferences and functions To enable/disable the confirmation boxConfirmation status box Orange dot indicators in the Select Host menu How do multiple users coexist? Global user accessWhat will I see when I first login? To access via the VNC viewer Global user access via VNC viewerTo download the VNC viewer Options buttonTo access via your web browser Global user access via web browserMenu bar Using the viewer windowWhen using the viewer window Mouse pointers ConfigureHost selection To select a hostPower switching Access mode shared/privateAuto calibrate Re-synchronise mouseControls When entering codes Enable Sun TranslationVideo Settings Keyboard ControlIncreased by 50% when a slow link is detected Using automatic configurationsSetting the Threshold manually Screen contains only host system informationShow All Users Advanced Video SettingsCustom Video Modes Reduced BlankingVNC hotkey selection Supported web browsers Viewer encryption settingsIf you need to enter a port number When logging on using VNC viewer, I cannot enter a username TroubleshootingGetting assistance US +1 888 275To access the local setup menus Appendix 1 Local setup menusRestore Standard Mouse Power ControlRestore Intellimouse FunctionsSettings Disabled, Enabled Settings Blank, Moving LogoUser Preferences Screen SaverUser Timeout Mouse SwitchingGlobal Preferences OSD Dwell TimeAuto Logout Setup OptionsLogon Security IP admin password, encryption settings, etc ConfigurationCompletely resets the AdderView CATxIP 5000 unit IP address, net mask, VNC port, etcUnit Configuration Network Configuration Settings Power Control, Sync Units Serial ConfigurationSettings 1200, 2400, 4800, 9600, 19200, 38400, 57600 Options PortTo reset the AdderView CATxIP 5000 configuration Reset ConfigurationMain configuration Logged on users Appendix 2 Configuration pages via viewerTo access the remote configuration pages User accounts Unit configuration Advanced unit configuration Time & date configuration IP Access Control Network configurationIP Network Mask IP GatewayTo define a new IP access control entry Setting IP access controlTo reorder access control entries To edit/remove access control entriesBaud Rate Serial port configurationOptions Port Use Erase Host Configuration Host configurationAdd entry for unrecognised host SortTo copy and paste the log Logging and statusSyslog Server IP Address For further details To get hereLdap configuration Colour/Encoding Appendix 3 VNC viewer connection optionsAuto select Preferred encodingDisable all inputs view-only mode Enable all inputsInputs CustomiseMisc No Scaling ScalingScale to Window Size Custom SizeDefaults Save Defaults ReloadIdentities Load / SaveAppendix 4 VNC viewer window options Security Appendix 5 Browser viewer optionsEncoding and colour level Net masks Appendix 6 Addresses, masks and portsIP addresses Operation with net mask Net masks the binary explanationBinary equivalent Binary octet afterSingle locations Calculating the mask for IP access controlAll locations Address rangesPorts Security issues with portsCascade tree Appendix 7 Cascading multiple unitsSee also To connect units in cascade Connecting units in cascadeTips for successful cascading Addressing computers in a cascade Using cascaded computersAdderView CATxIP 5000 to power switch cable Appendix 8 Cable and connector specificationsPower switch to power switch daisy chain cable Multi-head synchronisation cableCreating macro sequences Appendix 9 Hotkey sequence codesPermissible key presses Appendix 10 Supported video modes General Public License Linux WarrantySafety information End user licence agreement European EMC directive 89/336/EEC Radio Frequency EnergyFCC Compliance Statement United States Canadian Department of Communications RFI statementHoe Huat Industrial Building Index Options port Upgrade failure Connection Baud rate