Adder Technology 5000 manual Advanced unit configuration

Page 64

Advanced unit configuration

Click this button to display advanced options that do not normally require alteration.

Force VNC Protocol 3.3

IMPORTANT: The use of this option is not recommended. Protocol 3.3 is a legacy version that does not offer any encryption.

Idle Timeout

Determines the period of inactivity on a global connection before the user is logged out. The idle timeout period can be set to any time span, expressed in minutes. Note: The Screensaver option serves a similar purpose for local connections.

Protocol Timeout

Sets the time period by which responses should have been received to outgoing data packets. If the stated period is exceeded, then a connection is considered lost and terminated.

Session Sleep Timeout

Determines the period of inactivity before the viewer screen will blank and a message is displayed. When no hosts are being viewed either because of this time out or if no viewers are active then parts of the video circuitry are powered down reducing power consumption by up to a third.

Background Refresh Rate

Use the arrow keys to alter the refresh rate for screen images via remote links. This allows you to tailor the screen refresh to suit the network or modem connection speeds. The options are: Slow, Medium, Fast or Disabled. When the disabled option is selected, the remote users will need to manually refresh the screen.

Note: When a low connection speed is detected, the background refresh is automatically disabled, regardless of the settings of this option.

Mouse Latency Allowance

This option is used during calibration to account for latency delays that may be caused as signals pass through a device.

During calibration, the AdderView CATxIP 5000 waits for 40ms after each mouse movement before sampling the next. If a device adds a significant delay to the flow of data, the calibration process can be lengthened or may fail entirely. The value entered here is added to (or subtracted from) the default 40ms sampling time.

Note: You can enter negative values (down to -40) in order to speed up the calibration process when using fast KVM switches. Use this option with caution as it can adversely affect the calibration process.

Mouse Rate

Defines the rate at which mouse movement data are transmitted to the system. The default option is 20ms, which equates to 50 mouse events per second. This is used to slow down the rate in exceptional circumstances but normally requires no adjustment.

Single Mouse Mode Mouse Switch

Select the mouse button combination to exit from single mouse mode (when active).

Use Quick Mouse Calibration

Invokes optimised calibration techniques that handle the majority of mouse types.

Behaviour for admin connections when limit reached

Determines what should occur when four global connections already exist and a fifth, administrator connection attempt is made. Options are: Replace oldest connection, Replace newest connection and Don’t replace. Only non-administrator connections can be terminated in this way.

Use VESA GTF

When ticked, the VESA Generalized Timing Formula will be used to help determine the correct input video resolution and timing details. See Appendix 10 for a list of all supported video modes.

Upgrade firmware

Places the unit into upgrade mode. See Upgrading AdderView CATxIP 5000 models.

   



63

Image 64
Contents AdderView CATxIP Contents Further information Index CAM formats Many computersCascade installations Creating larger installationsEnterprise installations AdderView CATxIP 5000 features front and rear What you may additionally need What’s in the box  Single unit rack brackets MountingDouble unit rack brackets Connections   Local user To connect the local user portAdderView CATxIP Rear panel From video monitor From USB keyboard and mouseTo connect the IP network port for global users Global users IP network portAdderView CATxIP Front panel Computer system via CAM To connect a computer systemTo connect the power supply Power in connectionOutput lead from Power adapter To connect and address the switch boxes Power control portSwitch Multiple video head connections Host computer port/channel Remote switching controlCable from serial Control device Configuration Overall initial configurationInitial configuration Main menu Menu layoutHotkeys SecurityGeneral security and configuration steps To enable general securityTo set an Admin password Registering users and host computersWhat to do if the Admin password has been forgotten To clear a password and restore factory default settingsWhat is IP access control? Clearing IP access controlTo clear IP access control Full configuration by global user To configure the unit from a global user locationAdderView CATxIP 5000 encryption settings Encryption settingsViewer encryption settings Networking issues Positioning AdderView CATxIP 5000 in the networkPort settings Placing AdderView CATxIP 5000 behind a router or firewallAddressing Firewall/router addressTo discover a DHCP-allocated IP address DNS addressingEnsuring sufficient security Placing AdderView CATxIP 5000 alongside the firewallPorts Power switching configuration Power control sequencesTo configure the power sequences for each host computer To control two or more ports simultaneouslyRecovering from a failed upgrade To upgrade AdderView CATxIP 5000 modelsTo invoke backup/recovery mode Upgrading AdderView CATxIP 5000 modelsAccessing the AdderView CATxIP Front panel indicatorsLocal user access Selecting a computerTo select a computer using the Select Host menu When choosingStandard hotkeys Select Host menu here you can select computers by nameShow All Users Logging in and outConfirmation status box To enable/disable the confirmation boxUser preferences and functions Orange dot indicators in the Select Host menu What will I see when I first login? Global user accessHow do multiple users coexist? Global user access via VNC viewer To access via the VNC viewerTo download the VNC viewer Options buttonGlobal user access via web browser To access via your web browserWhen using the viewer window Using the viewer windowMenu bar Configure Mouse pointersHost selection To select a hostAccess mode shared/private Power switchingAuto calibrate Re-synchronise mouseControls Enable Sun Translation When entering codesVideo Settings Keyboard ControlUsing automatic configurations Increased by 50% when a slow link is detectedSetting the Threshold manually Screen contains only host system informationAdvanced Video Settings Show All UsersCustom Video Modes Reduced BlankingVNC hotkey selection If you need to enter a port number Viewer encryption settingsSupported web browsers Troubleshooting When logging on using VNC viewer, I cannot enter a usernameGetting assistance US +1 888 275Appendix 1 Local setup menus To access the local setup menusPower Control Restore Standard MouseRestore Intellimouse FunctionsSettings Blank, Moving Logo Settings Disabled, EnabledUser Preferences Screen SaverMouse Switching User TimeoutGlobal Preferences OSD Dwell TimeLogon Security Setup OptionsAuto Logout Configuration IP admin password, encryption settings, etcCompletely resets the AdderView CATxIP 5000 unit IP address, net mask, VNC port, etcUnit Configuration Network Configuration Serial Configuration Settings Power Control, Sync UnitsSettings 1200, 2400, 4800, 9600, 19200, 38400, 57600 Options PortReset Configuration To reset the AdderView CATxIP 5000 configurationTo access the remote configuration pages Appendix 2 Configuration pages via viewerMain configuration Logged on users User accounts Unit configuration Advanced unit configuration Time & date configuration Network configuration IP Access ControlIP Network Mask IP GatewaySetting IP access control To define a new IP access control entryTo reorder access control entries To edit/remove access control entriesOptions Port Use Serial port configurationBaud Rate Host configuration Erase Host ConfigurationAdd entry for unrecognised host SortLogging and status To copy and paste the logSyslog Server IP Address For further details To get hereLdap configuration Appendix 3 VNC viewer connection options Colour/EncodingAuto select Preferred encodingEnable all inputs Disable all inputs view-only modeInputs CustomiseMisc Scaling No ScalingScale to Window Size Custom SizeDefaults Reload Defaults SaveIdentities Load / SaveAppendix 4 VNC viewer window options Encoding and colour level Appendix 5 Browser viewer optionsSecurity IP addresses Appendix 6 Addresses, masks and portsNet masks Net masks the binary explanation Operation with net maskBinary equivalent Binary octet afterCalculating the mask for IP access control Single locationsAll locations Address rangesSecurity issues with ports PortsSee also Appendix 7 Cascading multiple unitsCascade tree Tips for successful cascading Connecting units in cascadeTo connect units in cascade Using cascaded computers Addressing computers in a cascadeAppendix 8 Cable and connector specifications AdderView CATxIP 5000 to power switch cablePower switch to power switch daisy chain cable Multi-head synchronisation cablePermissible key presses Appendix 9 Hotkey sequence codesCreating macro sequences Appendix 10 Supported video modes Safety information WarrantyGeneral Public License Linux End user licence agreement Radio Frequency Energy European EMC directive 89/336/EECFCC Compliance Statement United States Canadian Department of Communications RFI statementHoe Huat Industrial Building Index Options port Upgrade failure Connection Baud rate