38NETBUILDER SOFTWARE VERSION 11.1 RELEASE NOTES
and route discovery are configured, bridge numbers must be unique for each bridge/router on the same ring, and LLC2 is enabled on token ring ports.
Token Ring Frame Copy Errors
For transparent bridge or source route transparent configurations, token ring end systems may generate a small number of MAC frame copy error reports when the NETBuilder II bridge/router token ring interface is initializing or when the bridge/router ages out a MAC address from its bridge table.
For the bridge/router to learn the MAC addresses of transparent end systems on the token ring, it copies a packet with an unknown source address and sets the
A source route only configuration eliminates frame copy errors. Frame copy errors do not occur in source route only environments when the NETBuilder bridge/routers are configured properly. This is because the NETBuilder bridge/router hardware filters
Table 13 shows the features supported on the NETBuilder II and NETBuilder
SuperStack II token ring bridge/routers.
Table 13 3Com Bridge/Routers and Supported Features
| Source Route |
| Source Route |
|
| Transparent |
| Transparent |
|
Platform | Bridging | Routing | Gateway | Source Routing |
|
|
|
|
|
NETBuilder II | Yes | Yes | Yes | Yes |
SuperStack II NETBuilder | No | Yes | No | Yes |
Token Ring |
|
|
|
|
|
|
|
|
|
Frame Copy Errors under LAN Net Manager
Whenever LAN Net Manager is enabled, the token ring driver is set to
IPX Routing, Route When you route IPX over a Frame Relay meshed topology and configure the SAP Receive and Route Route Receive and Route Advertisement policies on the Frame Relay port, these
Advertisement Policies policies do not take effect until the SAP table is flushed.