Honeywell Mark III manual Main Menu

Page 30

Screens, including menus, can consist of multiple (up to 9) pages. Note the 1/2 in the upper right corner of the Main Menu display indicating page 1 of 2. Pages are accessed by using the Next and Previous page buttons on the display unit. Figure 13 shows page 2 of the example Main Menu.

Figure 13 Main Menu Page 2

HONEYWELL Aerospace Electronic Systems

Page 30

Use or disclosure of information on this page is subject to the restrictions on the title page of this document.

Image 30
Contents Honeywell Aerospace Electronic Systems Honeywell Aerospace Electronic Systems Introduction Mark III CMU OverviewDatalink Capability for Today and Tomorrow Honeywell Datalink Experience, Products, and Services Page Hardware Overview ArincArinc System InterfacesMark III CMU Interfaces Device Interface Baseline Specificati GrowthCMU Subnetwork InterfacesArinc VDR SDU Hfdr Arinc 750 VHF Data Radio VDRFlight Deck Devices Interfaces UHFControl and Display Unit CDU Mcdu Midu CDUPerformance Computer PZ LRU InterfacesFlight Management Computer FMC Aircraft Condition Monitoring System AcmsOther Interfaces Pcmcia Software OverviewMIL-STD-1553B OooiCMF VIACMU AOC HGI AMI Fidb Gbst Database DesignCertification Baseline Functionality AOA VDLM2Operations Uplink ProcessingDownlink Processing World RegionsSystem Pages DMT and DLTBite APM VDL ModeGrowth Functionality Data LoadingMil-STD Pcmcia Data LoadingArinc 761 Satcom Weather GraphicsEncryption/Authentication ATNRRI Page Databases FidbGbst Fidb ArchitectureFidb HGI AMI Menus Main MenuMain Menu CDU Main Menu Supporting Regional / Business Jet CDUs ATS Menu System Menu Uplinks Clearance UplinkClearance Message Elements Clearance Message References Reject Reasons Reject Reasons Values Downlinks Diversion Report DownlinkDiversion Reasons Divert Message Elements Print Definition Logic UnitsPreferred Channel Management Oooi Logic UnitRegions US Map Areas Mechanical Design Interconnect CCAPower Supply CCA Processor CCAInput/Output CCA Spare CCAs Growth Detailed Interface DefinitionCMC McduPrntr ADLVOICE/DATA MON SDI PGM VHF PGMOooi SEL CMUUnit Size Mechanical Packaging Unit WeightUnit Connectors and Mounts Cooling RequirementsEnvironmental Specifications Waterproofness DO-160D Section Power Input DO-160D SectionInduced Signal Susceptibility DO-160D Section Fluids Susceptibility DO-160D SectionPower Requirements 1 115 Vac Input Power Requirements2 28 Vdc Input Power Requirements 3 28 Vdc Backup Input Power Requirements Power Interrupt RequirementsTechnical Summary