AIR TECHNICAL SPECIFICATIONS

AIR Base-1 & AIR Base-2

 

 

System:

Active Subwoofers

Total frequency response:

25 Hz – bssmng: 120 Hz, LFE: 2.5 kHz/

 

 

23 Hz – bssmng: 120 Hz, LFE: 2.5 kHz : +/-3dB

 

Max. SPL 1m, one (IEC Short Term)

119 dB peak / 121 dB peak

Max. SPL 2m, 5.1 (IEC Short Term)

113 dB peak / 115 dB peak (no front, rear & center)

 

Precision of monitor matching:

+/- 0.2 dB

Port tuning frequency:

30 Hz / 27 Hz

 

Internal cabinet volume:

37 liters / 78 liters

Bass principle:

Bass reflex

 

Woofer:

1 / 2 pcs. 240 mm / 10", one-piece molded polyprop cone, 100

 

mm / 4" pure alu voice coil

Mains voltage:

100 to 240 VAC, 50 to 60 Hz (auto-select)

 

Power consumption:

40 W @ 1/8 max power (IEC 60065)

 

 

 

Finish

 

 

Amp:

Black anodized aluminum back plate

 

Cabinet:

Dark gray MDF baffle, Silver foil

Dimensions (H x W x D):

310 x 480 x 420mm / 900 x 310 x 420mm

 

 

(12.2” x 18,9” x 16.5” / 35.4” x 12.2” x 16.5”)

 

 

Depth incl. amp and driver: 447mm / 447mm (17.6” / 17.6”)

 

Weight:

18 kg / 29 kg (39.6 lbs / 63.8 lbs)

 

Amplifier

250 W PWM amp

Room & Distance

Typical listening distance

 

 

 

AIR 6

AIR 15

AIR 20

AIR 25

1.2-2 m / 4-7 ft

1.5-2.5 m / 5-8,5 ft

1.5-3 m / 5-10.2 ft

 

Typical room size

 

 

 

AIR 6

AIR 15

AIR 20

AIR 25

50-100 m3 / 1600-3500 ft

75-125 m3 /2600-4400 ft

80-130 m3 / 2800-4600 ft3

 

AIR Base-1

AIR Base-2

Two or three AIR Base-1’s

Two or three AIR Base-1’s

30-60 m3 / 1000-2000 ft3

50-100 m3 / 1600-4400 ft3

50-100 m3 / 1600-3500 ft3

75-125 m3 / 2600-4400 ft3

 

 

 

 

General specifications for AIR 6, AIR 15, AIR 20, AIR 25, AIR Base-1 & AIR Base-2

System sample rates

 

Internal sample rate

192 and 176.4 via Dual Wire (optional Digital Card required) and

 

96, 88.2, 64, 48, 44.1 or 32 kHz

 

 

AIR Masters only

 

I/O Connectors

XLR (2 channels AES/EBU in) 3 x RJ45 proprietary TC LINK

Formats

AES/EBU (24 bit)

Word clock input

BNC, 75 ohm, 0.6 to 10 Vpp

Display

2 x 16 character dot matrix

Operation

Menu system / four buttons

 

 

Analog input option

 

Input connectors

XLR balanced (pin 2+, pin 3-)

Impedance

10/3 k Ohm (Balanced/unbalanced)

Selectable full scale input level

+9, +15, +21, +27 dBu

Dynamic Range

> 113 dB typ. (unweighted), BW: 20-20kHz

THD+N

< -105 dB typ. @ 1 kHz, -3 dBFS

Crosstalk

< -120 dB, 20 Hz to 20 kHz

A to D Conversion

24 bit (Dual bit delta sigma sampling at 4.1/5.6/6.1/6.1 MHz)

 

 

AIR Slaves only

 

I/O Connectors

2 x RJ45 proprietary TC LINK

General for all Products

EMC complies with:

EN 55103-1 and EN 55103-2, FCC part 15 class B, CISPR 22 class B

Safety certified to:

IEC 60065, EN 60065, UL 6500 and CSA E60065 CSA FILE

 

#LR108093

Environment operating Temperature:

32° F to 122° F (0° C to 50° C)

Storage Temperature:

-22° F to 167° F (-30° C to 70° C)

Humidity:

Max. 90 % non-condensing

Warranty

2 years on parts and labor

54

Image 56
Contents AirUSrev111.qxd 16-12-2004 1414 AirUSrev111.qxd 16-12-2004 1414 Important Safety Instructions Voltage Line plug according to standardQuick Setup Reference AirUSrev111.qxd 16-12-2004 1415 Page c Table of Contents Introduction This ManualBreak Product ConceptRemote Control Common FeaturesMaster Unit Slave & Sub UnitsRear Panel Description Master Master Unit Analog I/OSlave/Sub Optional Digital I/O cardOperational Overview Main DisplayGeneral Setup Procedure AIR Display & Setting UPSetting up Introduction Setups Stereo SetupStereo Setup with mono Subs Stereo Setup with stereo SubsDigital Setup Analog SetupThis illustration shows how to connect a 5.1 digital setup This illustration shows how to connect a 5.1 analog setupThis illustration shows how to connect a 5.3 Digital setup This illustration shows how to connect a 5.3 Analog setupThis illustration shows how to connect a 6.1 Analog setup Dig/6 MasterStereo Setup With Chains on L & R Other Chained SetupsDigital 192 kHz Digital Setup When the Monitors are Connected OverviewPress Enter to access the Select Mode Parameter DescriptionBasic operation in all menus Main DisplaySetup Menu SetupSet Monitor Task External ClockPresets In General LFE channel noteRecall StorePlacing the Monitors Other situations Close to wall / WallOn the bridge / Console Phase checking Checking by ear when listening to the signals In phaseEvaluation Checking the placingEqualizing NextCalibrating Main Monitors CurvesInterchannel calibration Acoustic level calibrationPlacing the Subwoofer Low frequency sweeps EvaluationChecking summing phase cancellation To CalibrateControlling standing waves Checking the CrosspointPolarity PhaseLFE Gain Reverberation time AcousticsGood acoustics Sabines formula Absorbers DiffusersMembrane absorbers Absorbtion or diffusion ? Resonance absorbersBackground Info Acoustics Standing WavesRoom modes Axial Tangential RadialHow to prohibit standing waves How does the standing waves influence the sound field?Acoustics Background Info Comb Filtering Or + Dip frequenciesRear wall cancellation Subwoofer Background Info SubwooferSubwoofer & LFE Channel Background Info LFE ChannelCross-overs Low Pass LFE GainCinema set-up Delaying Monitors LINE-UP & CalibrationAcoustic summation of audio signals Calibration of 5.1 in an ITU-775 arrangement How to measure the sound pressure?LINE-UP & Calibration Background Info Introduction Remote Control FeaturesAIR Remote Preset 1/3 and 2/4 keys Volume potentiometerREF Level 1-3 keys Shift keyAIR Soft Navigating AIR SoftMain ToolsPreset List NetworkSystem Setup Calibrate AIR Base Chained monitors Reset Procedures Miscellaneous Global Parameters Local ParametersCables TC Link Standard Cat-5 cablesAES/EBU Standard cables Serial to Cat-5 cableAIR 6 & AIR 15 Master and Slave AIR 20 & AIR 25 Master and SlaveGeneral for all Products AIR Base-1 & AIR Base-2Room & Distance AIR Remote specs AIR RemoteDelay in System & Error Messages ETC Error messages etcAIR Certificate of ConformityCertificate Of Conformity Preset List # Name