Badger Basket N64944-001, RAD-IOM-01 operation manual

Page 24

THE BADGER®-RADIX®User Guide

February 2007

Enter the reading and press the “Enter” button. If you wish to skip the manual read, press the “C” key.

When you have completed entries for this meter, press the “S” (Skip) button. It returns the Badger-Radix to the read screen in automatic mode.

Clearing a Tamper

If a Badger ORION transmitter reports a tamper condition, you must perform maintenance on the unit to clear the tamper condition. Once the condition that caused the tamper is cleared, the unit must be reprogrammed if it is connected to a Badger Recordall® Transmitter Register (RTR®) using the ORION programming tool. If the Badger ORION transmitter is connected to a position-based encoder like Badger Meter’s Absolute Digital Encoder (ADE®), no programming is required. Successfully resetting the odometer value will clear the tamper report. Please refer to the Badger ORION PROGRAMMER section for more information.

Switching to Manual Mode Meter Reading

The Badger-Radix switches from automatic to manual mode when the “A” key is pressed or an action by the meter reader is required. For example:

The Badger-Radix will switch to manual mode when the meter reader uses the hotkey function on the keypad, such as a search, or to enter a trouble code or comment code.

The Badger-Radix will automatically switch to manual mode when the next unread meter is a manually read meter or a touch-type meter.

The read screen for manual mode looks like this.

Page 23 of 73

Image 24
Contents BadgerMeter, Inc Introduction Page Badger-Radix Glossary BADGER-RADIXUser Guide Makeup of the Badger-Radix BADGER-RADIX LOADER-CHARGER Conserving the Battery Charging the Battery Page Details the Badger-Radix Operation Page Page Page Page Page Page Details Reading Meters with BADGER-RADIX Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page BADGER-RADIXUser Guide February Page Setting What IT does HOW YOU Might USE Connect Page Orion Page Page Page Page Page Page Details Programming Meters Using Page Page Page Page Page Page Page Details Other Uses for the BADGER-RADIX Page Page Page Page What if Things GO Wrong Page BadgerMeter, Inc