Acnodes RMC 7182 user manual Installing Windows on Non-RAID Systems

Page 101

RMC 7182

1U Rackmount System

B-2 Installing Windows on Non-RAID Systems

1.Insert Microsoft's Windows OS Setup CD in the CD-ROM drive and the sys- tem will start boot- ing up from the CD.

2.Continue with the installation. The Windows OS Setup screen will display.

3.From the Windows OS Setup screen, press the <Enter> key. The OS Setup will automatically load all device files and then continue with the Windows installation.

4.After the installation has completed, the system will automatically reboot.

5.Insert the Acnodes Setup CD that came with your system into the CD- ROM drive during system boot and the main screen will display.

 

© Copyright 2009 Acnodes, Inc.

661 Brea Canyon Rd., Suite 3

All rights reserved. Product description and product specifications

Walnut, CA 91789

are subject to change without notice. For latest product information,

tel: 909.598.7388, fax: 909.598.0218

please visit Acnodes’ web site at www.acnodes.com.

Image 101
Contents RMC Copyright 2005 Acnodes, Inc Manual Organization PrefaceBios Advanced Motherboard SetupAdvanced Chassis Setup Table of Contents System Interface Installing the System in to a RackAdvanced Motherboard Setup NIC2 JLAN2 LED NIC1 JLAN1 LED Advanced Chassis Setup Bios Overview IntroductionOther Features Motherboard FeaturesProcessor MemoryRMC System Power Server Chassis FeaturesSata Subsystem Control PanelPreparing for Setup Choosing a Setup LocationOverview Unpacking the SystemServer Precautions Rack PrecautionsRack Mounting Considerations Identifying the Sections of the Rack Rails Installing the System into a RackInner Rails Installing the Rack RailsOuter Rails RMC Installing the Chassis into a Rack Installing the Server into a Telco Rack Checking the Components Checking the Motherboard SetupRemoving the Chassis Cover Figure Providing Power Checking the Drive Bay SetupChecking the Drives Checking the AirflowControl Panel Buttons Reset ButtonPower Universal Information LED Control Panel LEDsNIC2 Drive Carrier LEDs Electrical Safety Precautions System SafetyGeneral Safety Precautions ESD Precautions Operating Precautions Handling the Motherboard PrecautionsUnpacking Serverboard InstallationInstalling to the Chassis Connecting Data Cables Connecting CablesConnecting Power Cables Connecting the Control PanelI/O Ports Installing an LGA1366 Processor Installing the Processor and HeatsinkRMC Installing a Passive CPU Heatsink Removing the Heatsink Installing & Removing DIMMs Installing Memory ModulesMaximum Memory Possible Memory SupportPCI Expansion Cards Installing a PCI Expansion CardServerboard Details RMC Main ATX Power Supply Connector Connector DefinitionsProcessor Power Connector Power ButtonOverheat/Fan Fail/UID LED HDD LED/UID SwitchPower On LED Fan Headers NMI ButtonATX PS/2 Keyboard and PS/2 Mouse Ports Serial PortsWake-On-LAN Chassis IntrusionExternal Speaker/Internal Buzzer Overheat/Fan Fail LEDPower Supply SMBus Connector Onboard Power LEDUniversal Serial Bus USB Sgpio HeadersAlarm Reset Power Supply Fail LED HeaderButton Unit Identifier ButtonVGA Enable/Disable Jumper SettingsExplanation of Jumpers Cmos ClearUSB Wake-Up LAN1/2 Enable/DisableWatch Dog Enable/Disable SAS Enable/Disable BMC Enable/DisableSAS RAID Mode Select SMBus to PCI SlotsOnboard Power LED LE1 Onboard IndicatorsLAN1/2 LEDs Ipmi Dedicated LAN LEDsSAS Heartbeat LED BMC Heartbeat LEDSAS Activity LED Sata and Floppy Drive Connections Floppy ConnectorSata Ports SAS PortsDriver/Tool Installation Display Screen Installing SoftwareRMC RMC Tools Required Static-Sensitive DevicesSystem Cooling Control PanelReplacing a System Fan Figure Adding a System FanSystem Fan Failure Accessing the Drive Bays Drive Bay Installation/RemovalHard Drive Installation Installing a Hard Drive into a Drive Carrier FigureRemoving a Hard Drive Figure DVD Drive Installation Power Supply Failure Power SupplyRemoving/Replacing the Power Supply Introduction Starting Bios Setup UtilityHow To Change the Configuration Data Starting the Setup Utility Main SetupSystem Memory System Time/System DateXboot Features Quick Boot Advanced Setup ConfigurationsQuiet Boot AddOn ROM Display ModePower Button Function Wait For F1 If ErrorRestore on AC Power Loss PS/2 Mouse SupportHardware Prefetcher Available when supported by the CPU Ratio Cmos SettingXProcessor & Clock Options CPU Ratio Clock Spread SpectrumIntel Eist Technology Active Processor CoresCore Ratio Limit Intel Turbo Boost Configuration Turbo Ratio Limit Program~ 3 Core Ratio Limit TDC Limit OverrideXAdvanced Chipset Control Temperature Rise Memory ModeQPI L0s and L1 Memory FrequencyAir Flow High Performance Event TimerAltitude Dimm PitchXide / Floppy Configuration Type IDE Detect Timeout secLBA/Large Mode Block Multi-Sector Transfer PIO ModeDMA Mode 32Bit Data Transfer A.R.T. For Hard disk drivesXPCI/PnP Configuration XRemote Access Configuration XSuper IO Device ConfigurationXHardware Health Configuration CPU Temperature System TemperatureFan Speed Control Modes Xacpi ConfigurationFan1 ~ Fan 5 Reading USB Device WakeUpAcpi Version Features XTrusted Computing TCG/TPM Support Headless ModeExecute TPM Command TPM Enable/Disable StatusXipmi Configuration BMC Watch Dog Timer Action Set PEF ConfigurationBMC WatchDog TimeOut MinSec XEvent Log ConfigurationView Event Log Mark all events as readSupervisor Password Security SettingsUser Password Change Supervisor PasswordBoot Sector Virus Protection Change User PasswordXHard Disk Drives Boot SettingsXBoot Device Priority Exit Options Retry Boot DevicesXRemovable Drives Save Changes and ExitLoad Fail-Safe Defaults Load Optimal DefaultsDiscard Changes and Exit Discard ChangesRecoverable Post Error Beep Codes Appendix a Post Error Beep CodesInstalling Windows on RAID Systems Appendix B Installing the Windows OSInstalling Windows on Non-RAID Systems Chipset ProcessorsMemory Capacity SAS ControllerPower Supply WeightChassis System Cooling