Acnodes RMC 7182 user manual XSuper IO Device Configuration, XRemote Access Configuration

Page 86

RMC 7182

1U Rackmount System

XSuper IO Device Configuration

Serial Port1 Address/ Serial Port2 Address

This option specifies the base I/O port address and the Interrupt Request address of Serial Port 1 and Serial Port 2. Select Disabled to prevent the serial port from accessing any system resources. When this option is set to Disabled, the serial port physically becomes unavailable. Select 3F8/IRQ4 to allow the serial port to use 3F8 as its I/O port address and IRQ 4 for the interrupt address. The options for Serial Port1 are Disabled, 3F8/IRQ4, 2E8/IRQ3. The options for Serial Port2 are Dis- abled, 2F8/IRQ3, and 2E8/IRQ3.

Serial Port 2 Mode

Use this feature to configure Serial Port 2 mode. The options are Normal, IrDA and ASK IR. IrDA (Infra-Red Data) is an industry standard for remote control devices. ASK IR (Amplitude Shifted Keying Infra-Red) is a protocol compatible with Sharp® branded PDAs and other infra-red devices.

Floppy Controller

Select Enabled to enable the onboard Floppy Controller. The options are Enabled and Disabled.

XRemote Access Configuration

Remote Access

This allows the user to enable the Remote Access feature. The options are Disabled and Enabled.

If Remote Access is set to Enabled, the following items will display:

Serial Port Number

This feature allows the user decide which serial port to be used for Console Redirection. The op- tions are COM 1 and COM 2. An additional option, Onboard IPMI is featured on the X8STi-F/X8STi- 3F motherboard only and becomes the default.

Serial Port Mode

This feature allows the user to set the serial port mode for Console Redirection. The options are 115200 8, n 1; 57600 8, n, 1; 38400 8, n, 1; 19200 8, n, 1; and 9600 8, n, 1.

Flow Control

This feature allows the user to set the flow control for Console Redirection. The options are None, Hardware, and Software.

 

© Copyright 2005 Acnodes, Inc.

661 Brea Canyon Rd., Suite 3

All rights reserved. Product description and product specifications

Walnut, CA 91789

are subject to change without notice. For latest product information,

tel: 909.598.7388, fax: 909.598.0218

please visit Acnodes’ web site at www.acnodes.com.

Image 86
Contents RMC Copyright 2005 Acnodes, Inc Preface Manual OrganizationBios Advanced Motherboard SetupAdvanced Chassis Setup Table of Contents Installing the System in to a Rack System InterfaceAdvanced Motherboard Setup NIC2 JLAN2 LED NIC1 JLAN1 LED Advanced Chassis Setup Bios Introduction OverviewProcessor Motherboard FeaturesOther Features MemoryRMC Sata Subsystem Server Chassis FeaturesSystem Power Control PanelOverview Choosing a Setup LocationPreparing for Setup Unpacking the SystemRack Precautions Server PrecautionsRack Mounting Considerations Installing the System into a Rack Identifying the Sections of the Rack RailsInstalling the Rack Rails Inner RailsOuter Rails RMC Installing the Chassis into a Rack Installing the Server into a Telco Rack Checking the Components Checking the Motherboard SetupRemoving the Chassis Cover Figure Checking the Drives Checking the Drive Bay SetupProviding Power Checking the AirflowControl Panel Buttons Reset ButtonPower Control Panel LEDs Universal Information LEDNIC2 Drive Carrier LEDs System Safety Electrical Safety PrecautionsGeneral Safety Precautions ESD Precautions Operating Precautions Precautions Handling the MotherboardUnpacking Serverboard InstallationInstalling to the Chassis Connecting Power Cables Connecting CablesConnecting Data Cables Connecting the Control PanelI/O Ports Installing the Processor and Heatsink Installing an LGA1366 ProcessorRMC Installing a Passive CPU Heatsink Removing the Heatsink Installing Memory Modules Installing & Removing DIMMsMemory Support Maximum Memory PossibleInstalling a PCI Expansion Card PCI Expansion CardsServerboard Details RMC Processor Power Connector Connector DefinitionsMain ATX Power Supply Connector Power ButtonOverheat/Fan Fail/UID LED HDD LED/UID SwitchPower On LED ATX PS/2 Keyboard and PS/2 Mouse Ports NMI ButtonFan Headers Serial PortsExternal Speaker/Internal Buzzer Chassis IntrusionWake-On-LAN Overheat/Fan Fail LEDUniversal Serial Bus USB Onboard Power LEDPower Supply SMBus Connector Sgpio HeadersButton Power Supply Fail LED HeaderAlarm Reset Unit Identifier ButtonExplanation of Jumpers Jumper SettingsVGA Enable/Disable Cmos ClearUSB Wake-Up LAN1/2 Enable/DisableWatch Dog Enable/Disable SAS RAID Mode Select BMC Enable/DisableSAS Enable/Disable SMBus to PCI SlotsLAN1/2 LEDs Onboard IndicatorsOnboard Power LED LE1 Ipmi Dedicated LAN LEDsSAS Heartbeat LED BMC Heartbeat LEDSAS Activity LED Sata Ports Floppy ConnectorSata and Floppy Drive Connections SAS PortsInstalling Software Driver/Tool Installation Display ScreenRMC RMC Static-Sensitive Devices Tools RequiredControl Panel System CoolingReplacing a System Fan Figure Adding a System FanSystem Fan Failure Hard Drive Installation Drive Bay Installation/RemovalAccessing the Drive Bays Installing a Hard Drive into a Drive Carrier FigureRemoving a Hard Drive Figure DVD Drive Installation Power Supply Power Supply FailureRemoving/Replacing the Power Supply Introduction Starting Bios Setup UtilityHow To Change the Configuration Data Main Setup Starting the Setup UtilitySystem Time/System Date System MemoryQuiet Boot Advanced Setup ConfigurationsXboot Features Quick Boot AddOn ROM Display ModeRestore on AC Power Loss Wait For F1 If ErrorPower Button Function PS/2 Mouse SupportXProcessor & Clock Options CPU Ratio Ratio Cmos SettingHardware Prefetcher Available when supported by the CPU Clock Spread SpectrumActive Processor Cores Intel Eist Technology~ 3 Core Ratio Limit Intel Turbo Boost Configuration Turbo Ratio Limit ProgramCore Ratio Limit TDC Limit OverrideXAdvanced Chipset Control QPI L0s and L1 Memory ModeTemperature Rise Memory FrequencyAltitude High Performance Event TimerAir Flow Dimm PitchXide / Floppy Configuration Type IDE Detect Timeout secLBA/Large Mode Block Multi-Sector Transfer PIO ModeDMA Mode A.R.T. For Hard disk drives 32Bit Data TransferXPCI/PnP Configuration XSuper IO Device Configuration XRemote Access ConfigurationXHardware Health Configuration System Temperature CPU TemperatureFan1 ~ Fan 5 Reading Xacpi ConfigurationFan Speed Control Modes USB Device WakeUpExecute TPM Command Headless ModeAcpi Version Features XTrusted Computing TCG/TPM Support TPM Enable/Disable StatusXipmi Configuration Set PEF Configuration BMC Watch Dog Timer ActionView Event Log XEvent Log ConfigurationBMC WatchDog TimeOut MinSec Mark all events as readUser Password Security SettingsSupervisor Password Change Supervisor PasswordChange User Password Boot Sector Virus ProtectionXHard Disk Drives Boot SettingsXBoot Device Priority XRemovable Drives Retry Boot DevicesExit Options Save Changes and ExitDiscard Changes and Exit Load Optimal DefaultsLoad Fail-Safe Defaults Discard ChangesAppendix a Post Error Beep Codes Recoverable Post Error Beep CodesAppendix B Installing the Windows OS Installing Windows on RAID SystemsInstalling Windows on Non-RAID Systems Memory Capacity ProcessorsChipset SAS ControllerChassis WeightPower Supply System Cooling