MAC Address - The BIOS will automatically enter the MAC address of this machine, however it may be over-ridden. MAC addresses are 6 two-digit hexa- decimal numbers (Base 16, 0 ~ 9, A, B, C, D, E, F) separated by dots. (i.e.,00.30.48.D0.D4.60)

Subnet Mask - Subnet masks tell the network which subnet this machine be- longs to. The value of each three-digit number separated by dots should not exceed 255.

Set PEF Configuration

Set this feature to configure the Platform Event Filter (PEF). PEF interprets BMC

events and performs actions based on pre-determined settings or 'traps' under IPMI

1.5specifications. For example, powering the system down or sending an alert when a triggering event is detected.

The following will appear if PEF Support is set to Enabled. The default is Dis- abled.

PEF Action Global Control - These are the different actions based on BMC events. The options are Alert, Power Down, Reset System, Power Cycle, OEM Action, Diagnostic Interface.

Alert Startup Delay - This feature inserts a delay during startup for PEF alerts. The options are En- abled and Disabled.

PEF Alert Startup Delay - This sets the pre-determined time to delay PEF

alerts after system power-ups and resets. Refer to Table 24.6 of the IPMI 1.5

Specification for more information at www.intel.com. The options are No Delay,

30 sec, 60 sec, 1.5 min, 2.0 min.

Startup Delay - This feature enables or disables startup delay. The options are

Enabled and Disabled.

PEF Startup Delay - This sets the pre-determined time to delay PEF after system power-ups and resets. Refer to Table 24.6 of the IPMI 1.5 Specification for more information at www.intel.com. The options are No Delay, 30 sec, 60 sec, 1.5 min, 2.0 min.

Event Message for PEF Action - This enables of disables Event Messages for PEF action. Refer to Table 24.6 of the IPMI 1.5 Specification for more informa- tion at www.intel.com. The options are Disabled and Enabled.

BMC Watch Dog Timer Action

Allows the BMC to reset or power down the system if the operating system hangs or crashes. The options are Disabled, Reset System, Power Down, Power Cycle.

 

© Copyright 2005 Acnodes, Inc.

661 Brea Canyon Rd., Suite 3

All rights reserved. Product description and product specifications

Walnut, CA 91789

are subject to change without notice. For latest product information,

tel: 909.598.7388, fax: 909.598.0218

please visit Acnodes’ web site at www.acnodes.com.

Image 92
Contents RMC Copyright 2005 Acnodes, Inc Preface Manual OrganizationBios Advanced Motherboard SetupAdvanced Chassis Setup Table of Contents Installing the System in to a Rack System InterfaceAdvanced Motherboard Setup NIC2 JLAN2 LED NIC1 JLAN1 LED Advanced Chassis Setup Bios Introduction OverviewMotherboard Features Other FeaturesProcessor MemoryRMC Server Chassis Features System PowerSata Subsystem Control PanelChoosing a Setup Location Preparing for SetupOverview Unpacking the SystemRack Precautions Server PrecautionsRack Mounting Considerations Installing the System into a Rack Identifying the Sections of the Rack RailsInstalling the Rack Rails Inner RailsOuter Rails RMC Installing the Chassis into a Rack Installing the Server into a Telco Rack Checking the Components Checking the Motherboard SetupRemoving the Chassis Cover Figure Checking the Drive Bay Setup Providing PowerChecking the Drives Checking the AirflowControl Panel Buttons Reset ButtonPower Control Panel LEDs Universal Information LEDNIC2 Drive Carrier LEDs System Safety Electrical Safety PrecautionsGeneral Safety Precautions ESD Precautions Operating Precautions Precautions Handling the MotherboardUnpacking Serverboard InstallationInstalling to the Chassis Connecting Cables Connecting Data CablesConnecting Power Cables Connecting the Control PanelI/O Ports Installing the Processor and Heatsink Installing an LGA1366 ProcessorRMC Installing a Passive CPU Heatsink Removing the Heatsink Installing Memory Modules Installing & Removing DIMMsMemory Support Maximum Memory PossibleInstalling a PCI Expansion Card PCI Expansion CardsServerboard Details RMC Connector Definitions Main ATX Power Supply ConnectorProcessor Power Connector Power ButtonOverheat/Fan Fail/UID LED HDD LED/UID SwitchPower On LED NMI Button Fan HeadersATX PS/2 Keyboard and PS/2 Mouse Ports Serial PortsChassis Intrusion Wake-On-LANExternal Speaker/Internal Buzzer Overheat/Fan Fail LEDOnboard Power LED Power Supply SMBus ConnectorUniversal Serial Bus USB Sgpio HeadersPower Supply Fail LED Header Alarm ResetButton Unit Identifier ButtonJumper Settings VGA Enable/DisableExplanation of Jumpers Cmos ClearUSB Wake-Up LAN1/2 Enable/DisableWatch Dog Enable/Disable BMC Enable/Disable SAS Enable/DisableSAS RAID Mode Select SMBus to PCI SlotsOnboard Indicators Onboard Power LED LE1LAN1/2 LEDs Ipmi Dedicated LAN LEDsSAS Heartbeat LED BMC Heartbeat LEDSAS Activity LED Floppy Connector Sata and Floppy Drive ConnectionsSata Ports SAS PortsInstalling Software Driver/Tool Installation Display ScreenRMC RMC Static-Sensitive Devices Tools RequiredControl Panel System CoolingReplacing a System Fan Figure Adding a System FanSystem Fan Failure Drive Bay Installation/Removal Accessing the Drive BaysHard Drive Installation Installing a Hard Drive into a Drive Carrier FigureRemoving a Hard Drive Figure DVD Drive Installation Power Supply Power Supply FailureRemoving/Replacing the Power Supply Introduction Starting Bios Setup UtilityHow To Change the Configuration Data Main Setup Starting the Setup UtilitySystem Time/System Date System MemoryAdvanced Setup Configurations Xboot Features Quick BootQuiet Boot AddOn ROM Display ModeWait For F1 If Error Power Button FunctionRestore on AC Power Loss PS/2 Mouse SupportRatio Cmos Setting Hardware Prefetcher Available when supported by the CPUXProcessor & Clock Options CPU Ratio Clock Spread SpectrumActive Processor Cores Intel Eist TechnologyIntel Turbo Boost Configuration Turbo Ratio Limit Program Core Ratio Limit~ 3 Core Ratio Limit TDC Limit OverrideXAdvanced Chipset Control Memory Mode Temperature RiseQPI L0s and L1 Memory FrequencyHigh Performance Event Timer Air FlowAltitude Dimm PitchXide / Floppy Configuration Type IDE Detect Timeout secLBA/Large Mode Block Multi-Sector Transfer PIO ModeDMA Mode A.R.T. For Hard disk drives 32Bit Data TransferXPCI/PnP Configuration XSuper IO Device Configuration XRemote Access ConfigurationXHardware Health Configuration System Temperature CPU TemperatureXacpi Configuration Fan Speed Control ModesFan1 ~ Fan 5 Reading USB Device WakeUpHeadless Mode Acpi Version Features XTrusted Computing TCG/TPM SupportExecute TPM Command TPM Enable/Disable StatusXipmi Configuration Set PEF Configuration BMC Watch Dog Timer ActionXEvent Log Configuration BMC WatchDog TimeOut MinSecView Event Log Mark all events as readSecurity Settings Supervisor PasswordUser Password Change Supervisor PasswordChange User Password Boot Sector Virus ProtectionXHard Disk Drives Boot SettingsXBoot Device Priority Retry Boot Devices Exit OptionsXRemovable Drives Save Changes and ExitLoad Optimal Defaults Load Fail-Safe DefaultsDiscard Changes and Exit Discard ChangesAppendix a Post Error Beep Codes Recoverable Post Error Beep CodesAppendix B Installing the Windows OS Installing Windows on RAID SystemsInstalling Windows on Non-RAID Systems Processors ChipsetMemory Capacity SAS ControllerWeight Power SupplyChassis System Cooling