Metrologic Instruments MS7620 manual Installation of a Secondary Scanner

Page 19

INSTALLATION OF A SECONDARY SCANNER

1.Turn off the host system.

2.Connect the round end of the PowerLink RS232 AUX cable [MLPN 54-54667A] to the RS232 jack of the secondary scanner (see figure 20).

3.Connect the other end of the PowerLink RS232 AUX cable into the 3rd jack down from the top of the MS7600.

The following Metrologic scanners can be used in the “Aux” input of the MS7600: the MS9520, MS9540, MS7220, MS7120, MS6720, MS6220, MS6520, MS5145 or another MS7600.

Important: The MS7600 aux port requires the signals: transmit, receive, RTS & CTS from the secondary scanner.

4.Connect the MS7600/Host PowerLink* cable to the appropriate interface jack on the back of the MS7600.

5.Connect the other end of the MS7600/Host PowerLink cable to the host.

6.Connect the external power supplies for the secondary scanner and the MS7600 to the power jacks on the two PowerLink cables.

Before continuing verify that the PowerLink cables are connected to the appropriate interface jacks on the scanner. An incorrect cable connection can cause communication problems or potential damage to the scanner.

7.Insert the attached rubber plug into the remaining jack not being used on the MS7600.

8.Check the AC input requirements of both power supplies to make sure the voltage matches the AC outlets.

9.Connect AC power to the transformers. The outlets should be near the equipment and easily accessible.

10.Configure the MS7600 for the appropriate interface configuration settings*.

Continued on page 17.

*The MS7600/host cable connection is interface dependent. Refer to the installation steps provided for the type of interface (RS232, IBM 46xx, etc.) required for your application.

Caution:

To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950.

To maintain compliance with standard CSA C22.2 No. 60950-00/UL 60950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.

16

Image 19
Contents MS7600 Horizon Series Installation and User’s Guide Page Table of Contents Introduction Description Scanner and AccessoriesReplacement Parts N OT Press Before Installing Your MS7600Package Flow Mounting the MS7600 SeriesOption B Free Hanging Support Option C Trim Ring Mlpn 46-46641, Additional Purchase Turn on the host system Installation for Keyboard Wedge InterfaceStand-Alone Keyboard Interface Installation for STAND-ALONE Keyboard InterfaceIf you require USB Point of Sale communication protocols Installation for USB InterfaceManufacturers Note RS232 or Light Pen Interface Installation for RS232 or Light PEN InterfacesFor RS232 Communication Scan 1st RS232/IBM, Interface Installation for IBM 46XX InterfaceOCIA, Interface Installation for Ocia InterfaceInstallation of a Secondary Scanner Enable AUX Output Connector Orientation Top Secondary Scanner Setup Bottom Scanner Parts O t pEAS Deactivation Antenna Maintenance3, 4, 5, on SW1 & SW2 Label Locations Scanner LabelsRazzberry Tone Audible IndicatorsThree Beeps on power up One BeepVisual Indicators Continuous Razzberry Tone with both LEDs off Failure ModesFlashing Amber and One Razzberry Tone Flashing Red and Amber Two Razzberry TonesChanging the Beeper Tone Changing the Beeper Tone & VolumePower Save Modes and IR Detection Power Save Modes and IR Detection Scan Volume in Plane Perpendicular to Flow Scan Volume SpecificationsMinimum Bar Code Element Width Depth of Field by Minimum BAR Code Element WidthAll Interfaces Troubleshooting GuideCodes. The scanner defaults to Keyboard Wedge Only RS-232 Only Aux port operation with any interface Design Specifications Electrical RS232 Demonstration Program Keyboard Type Applications and ProtocolsKeyboard Country Type IBM KBW USB Default SettingsDTS/SIEMENS DTS/NIXDORF NCR F NCR S Default Settings ACK/NAK Default Settings Default settings for Aux interface Scanner and Cable Terminations Scanner Pinout ConnectionsMS762x-37 Keyboard Wedge Stand-Keyboard or USB Cable Connector Configurations Host End Cable Connector Configuration Limited Warranty Atención AvertissementAttenzione AchtungPatents Light Pen IndexUSB Page August