Metrologic Instruments MS7620 manual Dts/Siemens Dts/Nixdorf Ncr F Ncr S

Page 43

DEFAULT SETTINGS (CONTINUED)

PARAMETER

DEFAULT

OCIA

RS-232

LIGHT

IBM

KBW

USB

PEN

46XX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bars High as Scanned

 

 

 

9

 

 

 

 

 

 

 

 

 

 

 

Spaces High as Scanned

 

 

 

9

 

 

 

 

 

 

 

 

 

 

 

DTS/SIEMENS

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

DTS/NIXDORF

*

9

 

 

 

 

 

 

 

 

 

 

 

 

 

NCR F

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

NCR S

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

Poll Light Pen Source

 

 

 

9

 

 

 

 

 

 

 

 

 

 

 

Beeper Tone

Normal

9

9

9

9

9

9

 

 

 

 

 

 

 

 

Beep/Transmit Sequence

Before

9

9

9

9

9

9

Transmit

 

 

 

 

 

 

 

Beeper Volume

Loudest

9

9

9

9

9

9

 

 

 

 

 

 

 

 

Communication Timeout

None

9

9

9

9

9

9

 

 

 

 

 

 

 

 

Razzberry Tone on Timeout

 

9

9

9

9

9

9

 

 

 

 

 

 

 

 

Three Beeps on Timeout

 

9

9

9

9

9

9

 

 

 

 

 

 

 

 

No Beeps on Timeout

*

9

9

9

9

9

9

Enter Power Save Mode

10 mins.

9

9

9

9

9

9

 

 

 

 

 

 

 

 

Blink Power Save Mode

 

9

9

9

9

9

9

 

 

 

 

 

 

 

 

Laser OFF Power Save Mode

 

9

9

9

9

9

9

 

 

 

 

 

 

 

 

Laser & Motor OFF

 

9

9

9

9

9

9

Power Save Mode

 

 

 

 

 

 

 

 

Dual Action Power Save

 

9

9

9

9

9

9

Mode #1

 

 

 

 

 

 

 

 

Dual Action Power Save

*

9

9

9

9

9

9

Mode #2

Same Symbol Rescan

 

9

9

9

9

9

9

Timeout: 200 msecs

 

 

 

 

 

 

 

 

Same Symbol Rescan

 

 

 

 

 

 

 

Timeout: 500 msecs

*

9

9

9

9

9

9

Programmable in 50 msec

steps (MAX 6.35 seconds)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Same Symbol Rescan

 

9

9

9

9

9

9

Timeout: 1250 msecs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Same Symbol Rescan

 

9

9

9

9

9

9

Timeout: 2000 msecs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Intercharacter Delay

1 msecs

9

9

 

9

9

 

Programmable in 1 msec

10 msecsin

 

 

steps (MAX 255 msecs)

KBW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40

Image 43
Contents MS7600 Horizon Series Installation and User’s Guide Page Table of Contents Introduction Description Scanner and AccessoriesReplacement Parts N OT Press Before Installing Your MS7600Package Flow Mounting the MS7600 SeriesOption B Free Hanging Support Option C Trim Ring Mlpn 46-46641, Additional Purchase Turn on the host system Installation for Keyboard Wedge InterfaceStand-Alone Keyboard Interface Installation for STAND-ALONE Keyboard InterfaceIf you require USB Point of Sale communication protocols Installation for USB InterfaceManufacturers Note RS232 or Light Pen Interface Installation for RS232 or Light PEN InterfacesFor RS232 Communication Scan 1st RS232/IBM, Interface Installation for IBM 46XX InterfaceOCIA, Interface Installation for Ocia InterfaceInstallation of a Secondary Scanner Enable AUX Output Connector Orientation Top Secondary Scanner Setup Bottom Scanner Parts O t pEAS Deactivation Antenna Maintenance3, 4, 5, on SW1 & SW2 Label Locations Scanner LabelsRazzberry Tone Audible IndicatorsThree Beeps on power up One BeepVisual Indicators Continuous Razzberry Tone with both LEDs off Failure ModesFlashing Amber and One Razzberry Tone Flashing Red and Amber Two Razzberry TonesChanging the Beeper Tone Changing the Beeper Tone & VolumePower Save Modes and IR Detection Power Save Modes and IR Detection Scan Volume in Plane Perpendicular to Flow Scan Volume SpecificationsMinimum Bar Code Element Width Depth of Field by Minimum BAR Code Element WidthAll Interfaces Troubleshooting GuideCodes. The scanner defaults to Keyboard Wedge Only RS-232 Only Aux port operation with any interface Design Specifications Electrical RS232 Demonstration Program Keyboard Type Applications and ProtocolsKeyboard Country Type IBM KBW USB Default SettingsDTS/SIEMENS DTS/NIXDORF NCR F NCR S Default Settings ACK/NAK Default Settings Default settings for Aux interface Scanner and Cable Terminations Scanner Pinout ConnectionsMS762x-37 Keyboard Wedge Stand-Keyboard or USB Cable Connector Configurations Host End Cable Connector Configuration Limited Warranty Atención AvertissementAttenzione AchtungPatents Light Pen IndexUSB Page August