Metrologic Instruments MS700i manual Configuring the Scanner

Page 10

Configuring the Scanner

Located in the Version 11 scanner are two computer boards. One board is for decoding and the other for 46XX IO processing. The decode board is configured using ScanSet™ or ScanSelect™ while the IO board is configured with an internal DIP Switch bank.

For UPC/EAN scanning, the decode board should be set as follows:

Enable IBM 4680 Communication

Enable UPC/EAN

Beep after Transmit

Enable Communication Timeouts

Transmit UPC-A Check Digit

Transmit UPC-E Check Digit

These settings configure the decode board to beep after transmitting the data to the terminal device driver. If the data does not clear the communications buffer within two seconds, it is discarded without giving the operator a good scan indication. This accommodates newer versions of the IBM device drivers that enable/disable scanning in many different situations.

The default setting of the interface board is to emulate the IBM 1520 hand scanner that supports UPC/EAN and alphanumeric code types. The following is a list of switch settings for the internal interface board that handles the 46XX SIOC communications.

There are eight DIP switches on the board that are both software and hardware switches.

Switch 1

Switch 2

Emulation Mode

OFF

OFF

Port 5B, IBM 1520 Model 2 Laser Scanner

 

 

(default setting)

OFF

ON

Port 9B, CCD (IBM 4500/Opticon)

ON

OFF

Port 17, IBM 4014 Adaptor for 3687-2 to 468X

ON

ON

Reserved

Switch 3

Reserved (Should be OFF)

Switches 4, 5, 6, and 7

Must be ON

Switch 8

Should be OFF (Reserved)

7

Image 10
Contents Installation and User’s Guide MS700i Series Laser Bar Code Projection ScannerTable of Contents Appendix C Appendix aAppendix B Appendix DIntroduction Unpacking List Scanner Connections to the Host Configuration of the Scanner to the Host System Cloning Feature CloningVersion 11 IBM 46XX Scanner Configuring the Scanner Configuring the IBM IBM 4684 and 4694 SystemsScanner Installation to a PC Keyboard Port PC TypePage PC Application Note Installation of the MS700 Series Stand Attaching the Scanner to the Stand MS700i and MS720i Series Features Scanner performs a good read of a bar codeVisual Indicators No Red or Green LEDSignaux optiques Ni la diode rouge, ni la diode verte nest alluméeOptische Anzeigen Weder rote noch grüne LeuchtdiodenanzeigeSegnali ottici Né il diodo luminoso rosso né quello verde sono accesiVolume Settings Labels InfraRed IR Object Sensor Symbol Orientation Active Scan Region for the MS700i and MS715i Scanner Active Scan Region for the MS720i Scanner Page Horizontal Scan Width vs. Distance for the MS720i Scanner Depth of Field for the MS700i and MS715i Scanner Code Density Code TypeMil /1000 Page Depth of Field for the MS720i Scanner Code Type Minimum Small Code Density Element Mil /1000Page Applications and Protocols MaintenanceScanner Version Identifier Communication Protocols Mechanical SpecificationsAppendix a ElectricalOperational EnvironmentalDefault Settings Appendix BSweda Three Beeps on Timeout No Beeps on IR Timeout Baud Rate Parallel Light 46XX Parallel Light Pen 46XX 232 Appendix C Pin FunctionVersion 2 Pin Assignments for Parallel Communication EOTVersion 26 Pin Assignments for Multi-drop RS-422 Versions 11 and 24 Pin Assignments for RS-485 Pin Function Warranty and Disclaimer Limited Warranty Appendix DDisclaimer Appendix E RemarqueAnmerkung Appendix F PatentsIndex LEDLaserklasse UL/CSA/TUV