Metrologic Instruments MS700i manual Version 26 Pin Assignments for Multi-drop RS-422

Page 47

Version “26” Pin Assignments for Multi-drop RS-422

The version “26” scanner head cable is terminated with a male 25-pin D-type connector. To connect the scanner to the host device, may require a communication cable. The communication cable may include a connection for a transformer or it may be designed to draw power directly from the host device. This item can be ordered at the same time scanner is purchased.

The version “26” scanner is designed to be used for Point to Point RS-422 communication.

The following is a list of the pin assignments. The pin numbers are impressed on the head cable’s connector.

Pin

Function

1

AC Shield Ground

2

RS-232 Receive Input

3

RS-232 Transmit Output

4

CTS Input

5

RTS Output

6

Reserved

7

Signal Ground

8

Reserved

9

Master Data +

10

Master Data -

11

Slave Data +

12

Slave Data -

13

Earth Ground

14

Power Ground 1

15

Light Pen Source

16

Light Pen Data

17

OCIA Clock In Return

18

OCIA Clock In

19

Power (11 - 30 volts) DC

20

DTR Input

21

OCIA Clock Out

22

OCIA Clock Out Return

23

OCIA RDATA

24

OCIA RDATA Return

25

Power Ground 2

44

Image 47
Contents MS700i Series Laser Bar Code Projection Scanner Installation and User’s GuideTable of Contents Appendix D Appendix aAppendix B Appendix CIntroduction Unpacking List Scanner Connections to the Host Configuration of the Scanner to the Host System Cloning Cloning FeatureVersion 11 IBM 46XX Scanner Configuring the Scanner IBM 4684 and 4694 Systems Configuring the IBMPC Type Scanner Installation to a PC Keyboard PortPage PC Application Note Installation of the MS700 Series Stand Attaching the Scanner to the Stand Scanner performs a good read of a bar code MS700i and MS720i Series FeaturesNo Red or Green LED Visual IndicatorsNi la diode rouge, ni la diode verte nest allumée Signaux optiquesWeder rote noch grüne Leuchtdiodenanzeige Optische AnzeigenNé il diodo luminoso rosso né quello verde sono accesi Segnali otticiVolume Settings Labels InfraRed IR Object Sensor Symbol Orientation Active Scan Region for the MS700i and MS715i Scanner Active Scan Region for the MS720i Scanner Page Horizontal Scan Width vs. Distance for the MS720i Scanner Depth of Field for the MS700i and MS715i Scanner Mil /1000 Code TypeCode Density Page Depth of Field for the MS720i Scanner Element Mil /1000 Code Type Minimum Small Code DensityPage Scanner Version Identifier Communication Protocols MaintenanceApplications and Protocols Electrical SpecificationsAppendix a MechanicalEnvironmental OperationalAppendix B Default SettingsSweda Three Beeps on Timeout No Beeps on IR Timeout Baud Rate Parallel Light 46XX Parallel Light Pen 46XX 232 Pin Function Appendix CEOT Version 2 Pin Assignments for Parallel CommunicationVersion 26 Pin Assignments for Multi-drop RS-422 Versions 11 and 24 Pin Assignments for RS-485 Pin Function Appendix D Warranty and Disclaimer Limited WarrantyDisclaimer Remarque Appendix EAnmerkung Patents Appendix FLED IndexLaserklasse UL/CSA/TUV