Metrologic Instruments MS700i manual Version 2 Pin Assignments for Parallel Communication, Eot

Page 46

Version “2” Pin Assignments for Parallel Communication

The version “2” scanner head cable is terminated with a male 25-pin D-type connector. To connect the scanner to the host device, may require a communication cable. The communication cable may include a connection for a transformer or it may be designed to draw power directly from the host device. This item can be ordered at the same time scanner is purchased.

The version “2” scanner is designed to be used for Parallel communication.

The following is a list of the pin assignments. The pin numbers are impressed on the head cable’s connector.

Pin

Function

1

AC Shield Ground

2

RS-232 Receive Input

3

RS-232 Transmit Output

4

CTS Input

5

RTS Output

6

Reserved

7

Signal Ground

8

Reserved

9

Edit Check

10

EOT

11

Data Ready

12

Adaptor Ready

13

Earth Ground

14

Power Ground 1

15

Light Pen Source

16

Light Pen Data

17

Data 1

18

Data 2

19

Power (11 - 30 volts) DC

20

DTR Input

21

Data 3

22

Data 4

23

Data 5

24

Data 6

25

Power Ground 2

43

Image 46
Contents Installation and User’s Guide MS700i Series Laser Bar Code Projection ScannerTable of Contents Appendix C Appendix aAppendix B Appendix DIntroduction Unpacking List Scanner Connections to the Host Configuration of the Scanner to the Host System Cloning Feature CloningVersion 11 IBM 46XX Scanner Configuring the Scanner Configuring the IBM IBM 4684 and 4694 SystemsScanner Installation to a PC Keyboard Port PC TypePage PC Application Note Installation of the MS700 Series Stand Attaching the Scanner to the Stand MS700i and MS720i Series Features Scanner performs a good read of a bar codeVisual Indicators No Red or Green LEDSignaux optiques Ni la diode rouge, ni la diode verte nest alluméeOptische Anzeigen Weder rote noch grüne LeuchtdiodenanzeigeSegnali ottici Né il diodo luminoso rosso né quello verde sono accesiVolume Settings Labels InfraRed IR Object Sensor Symbol Orientation Active Scan Region for the MS700i and MS715i Scanner Active Scan Region for the MS720i Scanner Page Horizontal Scan Width vs. Distance for the MS720i Scanner Depth of Field for the MS700i and MS715i Scanner Code Density Code TypeMil /1000 Page Depth of Field for the MS720i Scanner Code Type Minimum Small Code Density Element Mil /1000Page Applications and Protocols MaintenanceScanner Version Identifier Communication Protocols Mechanical SpecificationsAppendix a ElectricalOperational EnvironmentalDefault Settings Appendix BSweda Three Beeps on Timeout No Beeps on IR Timeout Baud Rate Parallel Light 46XX Parallel Light Pen 46XX 232 Appendix C Pin FunctionVersion 2 Pin Assignments for Parallel Communication EOTVersion 26 Pin Assignments for Multi-drop RS-422 Versions 11 and 24 Pin Assignments for RS-485 Pin Function Warranty and Disclaimer Limited Warranty Appendix DDisclaimer Appendix E RemarqueAnmerkung Appendix F PatentsIndex LEDLaserklasse UL/CSA/TUV