2Connect the DB9F end of a DB9F/custom cable to the Control port on the Room Control Module. This cable isn’t supplied by SMART Technologies. It’s usually supplied by the third- party room control vendor.

NOTE: Do not use an off-the-shelf DB9 null-modem cable to connect the SMART Room Control Module to a third-party room-control system, as the DTR/DSR pin will cause the system to malfunction.

DB9F End of

DB9F/Custom Cable

Control Port

Use the following pin assignment for the cable:

Third-Party Room-

Rear Projection SMART Board 3000i Interactive Whiteboard

Control System

Room Control Module

Custom Connector

 

DB9F

RxD

 

 

 

 

3

TxD

 

 

 

 

TxD

2

RxD

RTS

 

8 CTS

CTS

 

 

 

7 RTS

 

 

 

Signal GND

 

 

5

Signal GND

 

 

3Connect the other end of the cable to the third-party room-control system.

Updating the Control Panel Firmware

If the control panel card in your 3000i uses firmware version 2.0, 2.10 or 2.11, you'll need to update the firmware to version 2.12.

NOTE: This procedure takes between 20 and 30 minutes. If you use a laptop computer to complete the following steps, make sure it’s connected to a continuous power source.

To determine your firmware version

1Disconnect the port in the SMART Board Control Panel as follows:

a Click the SMART Board icon in the System Tray and select Control Panel. The SMART Board Control Panel opens.

b On the Boards tab, select the port for your interactive whiteboard. c Click the Disconnect button.

99-00360-02 REV A0

Room Control Module Installation Guide for the 3000i

11

Image 15
Contents Room Control Module FCC Warning Contents Page About the Custom Straight-Through MOD4 I2C Cables Installing the Room Control ModuleRemoving the Blank Panel Completing the Computer 2 X-Port 20 Serial Panel Connections MOD4 I2C Cable Inserting the Room Control Module Reconnect the computer 2 serial cable Updating the Control Panel Firmware Connecting the I2C Flash Adapter Cable Serial NoVertical Jack I2C Control Panel Flash Cable Connecting the I2C Control Panel Flash Cable Serial No Connecting to a Third-Party Room-Control System Use the following pin assignment for the cable Updating the Control Panel FirmwareTo update the control panel firmware Attempting to Program the Firmware on the Wonderbar Other Smart Contacts Product WarrantyCustomer Support Contacting Smart Technical Support