Smart Technologies 3000i manual Installing the Room Control Module

Page 5

Installing the Room Control Module

These instructions explain how to install the SMART Room Control Module (part No. 3000i-RCM). For information about programming the module to work with a third-party system, refer to the Room Control Module Integration Guide for the Rear Projection SMART Board™ 3000i Interactive Whiteboard.

You can use a third-party room-control system to change the projector settings for a Rear Projection SMART Board 3000i interactive whiteboard. However, when used on its own, a third-party room-control system doesn’t provide access to the many features available from the control panel on the 3000i. To provide an interface between the room control system and the 3000i, you need the SMART Room Control Module. You can then use the control panel or the room control system to change the standby state, source, display and volume settings for the 3000i.

NOTE: Check that the last four digits of the serial number for your 3000i are greater than 05000. The Room Control Module only works with SMART Board 3000i interactive whiteboards that have a serial number greater than 05000, because these units contain the SMART X-Port™ 20 switch.

The Room Control Module kit for the 3000i contains the following:

the Room Control Module

a custom straight-through MOD4 I2C cable with RJ11-6 (RJ12) connectors at both ends (part No. 93-199-00) and a tie wrap

a custom I2C flash adapter cable (part No. 93-00350-00) only for use if the serial number on your 3000i is between 05000 and 05999

an anti-static wrist strap

the warranty document

a diskette with the hex file for upgrading the control panel firmware

the Room Control Module Installation Guide and Room Control Module Integrator’s Guide

You’ll need a Phillips® No. 2 screwdriver and cutting pliers or wire cutters to perform the installation.

About the Custom Straight-Through MOD4 I2C Cables

Before you install the Room Control Module in the patch panel, you need to connect two cables. We supply one of the cables and you must reroute the other from inside the cabinet. Both are custom MOD4 I2C cables that use RJ11-6 (RJ12) connectors with four colored wires attached and identical pin assignments at both ends. The pin assignments for the connectors, shown below, are vital for the cables to work correctly.

WARNING: This is a custom straight-through cable, not a standard crossover telephone cable. Using a telephone cable instead of this custom cable could damage the Room Control Module and the 3000i.

 

 

Connector 1

 

 

 

Pin 1

 

 

 

 

 

 

 

 

Connector 2

 

 

 

 

Pin 1

 

MOD4 I2C Cable

 

 

Pin 1

Pin 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connector 1

 

Connector 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Blue, not used)

Pin 1

Pin 1

(Blue, not used)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yellow

Pin 2

Pin 2

Yellow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yellow

 

 

 

 

 

 

Black

Yellow

 

 

 

 

 

 

Black

Green

Pin 3

Pin 3

Green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Red

Pin 4

Pin 4

Red

 

 

 

 

 

 

Green Red

Green Red

Black

Pin 5

Pin 5

Black

Connector 1

Connector 2

(White, not used)

Pin 6

Pin 6 (White, not used)

99-00360-02 REV A0

Room Control Module Installation Guide for the 3000i

1

Image 5
Contents Room Control Module FCC Warning Contents Page About the Custom Straight-Through MOD4 I2C Cables Installing the Room Control ModuleRemoving the Blank Panel Completing the Computer 2 X-Port 20 Serial Panel Connections MOD4 I2C Cable Inserting the Room Control Module Reconnect the computer 2 serial cable Updating the Control Panel Firmware Connecting the I2C Flash Adapter Cable Serial NoVertical Jack I2C Control Panel Flash Cable Connecting the I2C Control Panel Flash Cable Serial No Connecting to a Third-Party Room-Control System Use the following pin assignment for the cable Updating the Control Panel FirmwareTo update the control panel firmware Attempting to Program the Firmware on the Wonderbar Customer Support Product WarrantyContacting Smart Technical Support Other Smart Contacts