It is possible to more accurately control the temperature of water coming in to the machine during a fill step. This does not apply to “Aux Fill” step. The control will mix the hot and cold water inlet to the temperature programmed in the fill function. To fill in the temperature, select the water inlet type and the water level. Press the “Heat” button and the control will ask the temperature. In this way the water inlet type selected is of no use because the control will mix between the cold and hot water inlet to reach the temperature.
Example: Fill to low level and 95°F (step time limit:
5 minutes 30 seconds).
Step XX Cycle XX
Warm
Step XX Cycle XX
Warm Low
Step XX Cycle XX 0°F
Step XX Cycle XX 95°F
Programming
Step XX Cycle XX
95°F Low
Step XX Cycle XX 0 min
Step XX Cycle XX 5 min 30 sec
9001889 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 9 |