Alliance Laundry Systems 9001889R7 manual During acceleration-If a current of more

Page 60

Inverter Drive Error Codes

Operation

Name

Description and NOTES

Check point

Corrective action

Panel

Indication

 

 

 

 

 

 

 

 

 

Stall prevention

During acceleration–If a current of more

Check to make sure

Load the machine

 

(overcurrent)

than 150% of the rated inverter current

the machine is

properly to

 

 

flows in the motor this function stops the

loaded properly and

distribute the load

 

 

increase in frequency until the overload

that the load is

evenly.

 

 

current reduces to prevent the inverter

balanced.

Contact Alliance

 

 

from resulting in overcurrent shut-off.

Verify that the AC

Laundry Systems’

 

 

When the overload current has reduces

drive’s parameters

Customer Service

 

 

are correct.

department.

 

 

below 150%, this function increases the

 

 

 

 

 

 

 

 

frequency again.

 

 

 

 

 

 

During constant-speed operation–If a

 

 

 

 

 

 

current of more than 150%, this function

 

 

 

 

 

 

lowers the frequency again.

 

 

 

 

 

 

When the overload current has reduces

 

 

 

 

 

 

below 150%, this function increases the

 

 

 

 

 

 

frequency again.

 

 

 

 

 

 

During deceleration–If a current of more

 

 

 

 

 

 

than 150% of the rated inverter current

 

 

 

 

 

 

flows in the motor, this function stops the

 

 

 

 

 

 

decrease in frequency until the overload

 

 

 

 

 

 

current reduces to prevent the inverter

 

 

 

 

 

 

from resulting in overcurrent shut-off.

 

 

 

 

 

 

When the overload current has reduced

 

 

 

 

 

 

below 150%, this function decreases the

 

 

 

 

 

 

frequency again.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stall prevention

During deceleration-If the regenerative

Check to make sure

Load the machine

 

(overvoltage)

energy of the motor exceeds the brake

the machine is loaded

properly to distribute

 

 

capability, this function stops the decrease

properly and that the

the load evenly.

 

 

in frequency to prevent overvoltage

load is balanced.

 

 

 

shutoff. As soon as the regenerative

 

 

 

 

 

 

energy has reduced, deceleration resumes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PU stop

A stop made by pressing the

STOP

key of

Check for a stop made

Perform operation

 

RESET

 

 

the PU has been set in Pr. 75 “PU stop

by pressing the

STOP

 

correctly.

 

 

RESET

 

 

selection”.

key of the operation

 

 

 

 

 

 

panel during external

 

 

 

 

 

 

operation.

 

 

 

 

 

 

 

 

 

 

 

 

This alarm appears if:

 

 

 

Perform operation

 

 

The RES signal is on;

 

 

 

correctly.

 

 

You attempted to set any parameter

 

 

 

 

 

 

value in the external operation mode;

 

 

 

 

 

 

You attempted to change the operation

 

 

 

 

 

 

mode during operation;

 

 

 

 

 

 

You attempted to set any parameter

 

 

 

 

 

 

value outside its setting range.

 

 

 

 

 

 

You attempted to set any parameter

 

 

 

 

 

 

value during operation (while signal

 

 

 

 

 

 

STF or STR is ON).

 

 

 

 

 

 

You attempted to set any parameter

 

 

 

 

 

 

value while parameter write is being

 

 

 

 

 

 

inhibited in Pr. 77 “parameter write

 

 

 

 

 

 

inhibit selection”.

 

 

 

 

58

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

9001889

Image 60
Contents Washer-Extractors Page 9001889 Contents Introduction Model IdentificationSetup of the Machine ProgrammingPress the Enter button to select options Programming Program Storing Mode Version of ControlExplanation of the Step Functions FillProgramming Wash Chemical Hold Feature Soak Spin Example Making a New Program Cycle Heat Wash 4 10/20 Cycle Cycle Cycle 51 Spin Cycle 51 0 min Cycle 51 8 min 30 sec End Edit a Cycle Change a Complete StepXxxxxxxx Changing the Time of a Step Press Enter to go to the next step Delete a Step Insert a Step Programming Delete a Cycle Reloading Previous Settings Cycle Count Reading Cycle CountCalibration of the Machine Speed Calibration Pre-Programmed Cycles Cycle Towels Light Soil Step Description Minsec Cycle Towels Medium Soil Step Description Minsec Cycle Blankets Warm Step Description Minsec Cycle Rinse and Spin Step Description Minsec Cycle Health Care Sheets Light Soil Step Description Minsec Cycle Health Care Towels Heavy Soil Step Description Minsec Cycle Health Care Cotton Blankets Step Description Minsec Cycle Health Care Personal No Bleach Step Description Minsec Cycle Health Care Pads Polyester Step Description Minsec Cycle Table Color Iron Step Description Minsec Cycle Table Color No Iron Step Description Minsec Pre-Programmed Cycles Visa No Iron Step Description Minsec Cycle Visa Color No Iron Step Description Minsec Cycle Shirt Color No Bleach Step Description Minsec Cycle Shirt Delicate Step Description Minsec Cycle Uniforms No Bleach Step Description Minsec Cycle Rags Heavy Soil Step Description Minsec Pre-Programmed Cycles Rewash/Reclaim Step Description Minsec Wash 1 18/3 32F 015 Drain 100 Pre-Programmed Cycles Energy Hot Step Description Minsec Cycle Energy Cold Step Description Minsec Pre-Programmed Cycles Normal 60C Step Description Minsec Cycle Gentle Cold Step Description Minsec Pre-Programmed Cycles Perm Press 60C Step Description Minsec Pre-Programmed Cycles Gentle 30C Step Description Minsec Inverter Drive Error Codes Indication During acceleration-If a current of more Indication