Alliance Laundry Systems 9001889R7 manual Indication

Page 59

Inverter Drive Error Codes

Operation

Name

Description and NOTES

Check point

Corrective action

Panel

Indication

 

 

 

 

 

 

Inverter

If a current of more than 150% of the rated

Verify that the AC

Contact Alliance

 

overload shut-

output current flows and overcurrent shut-

drive’s parameters are

Laundry Systems’

 

off (electronic

off does not occur (200% or less) inverse-

correct.

Customer Service

 

overcurrent

time characteristics cause the electronic

 

 

department.

 

protection)

overcurrent protection to be activated to

 

 

 

 

 

stop the inverter output in order to protect

 

 

 

 

 

the output transistors.

 

 

 

 

 

Note: Resetting the inverter initializes

 

 

 

 

 

the internal heat integrating data of the

 

 

 

 

 

electronic overcurrent protection.

 

 

 

 

 

 

 

 

 

 

Fin overheat

If the cooling fin overheats, the overheat

Check for too

Verify that the AC

 

 

sensor is actuated to stop the inverter

high ambient

drive’s parameters are

 

 

output.

temperature.

correct.

 

 

 

Check for

Contact Alliance

 

 

 

cooling fin clogging

Laundry Systems’

 

 

 

 

 

Customer Service

 

 

 

 

 

department.

 

 

 

 

 

 

 

Brake transistor

Internal Circuit Error

 

 

Contact Alliance

 

alarm detection

 

 

 

Laundry Systems’

 

 

 

 

 

Customer Service

 

 

 

 

 

department.

 

 

 

 

 

 

Output side

This function stops the inverter output if a

Check the motor cable

Repair the wiring.

 

ground fault

ground fault overcurrent flows due to a

insulation and

 

 

overcurrent

ground fault which occurred in the

connection for output

 

 

protection

inverter’s output (load) side. Use Pr. 249

short-circuit/ground

 

 

 

“ground fault detection at start” to set

fault.

 

 

 

 

whether the protective function is to be

 

 

 

 

 

activated or not. (In the 400V class, the

 

 

 

 

 

protective function is always active.)

 

 

 

 

 

 

 

 

 

External thermal

If the external thermal relay designed for

Check for motor

Load the machine

 

relay operation

motor overheat protection or the internally

overheating.

properly to distribute

 

 

mounted temperature relay in the motor

Check to make sure

the load evenly.

 

 

switches on (contacts open), the inverter

the machine is loaded

 

 

 

output is stopped. If the relay contacts are

properly and that the

 

 

 

reset automatically, the inverter will not

load is balanced.

 

 

 

restart unless it is reset.

 

 

 

 

 

 

 

 

 

Stall prevention

The running frequency has fallen to 0 with

Check the motor for a

Verify that the AC

 

 

stall prevention activated.

“locked rotor”

drive’s parameters are

 

 

 

condition.

correct.

 

 

 

 

 

Contact Alliance

 

 

 

 

 

Laundry Systems’

 

 

 

 

 

Customer Service

 

 

 

 

 

department.

 

 

 

 

 

 

Output phase

This function stops the inverter output if

Check the wiring.

Tighten the wire

 

failure

one of the three phases (U, V, W) on the

Check the motor for a

connections.

 

protection

inverter’s output side (load side) results in

fault.

 

Replace the

 

 

open phase.

 

 

connectors as needed.

 

 

 

 

 

 

Fan fault

For the inverter which contains a cooling

Check the cooling

Replace the fan as

 

 

fan, FN appears on the operation panel

fan’s operation.

needed.

 

 

when the cooling fan fails.

 

 

 

 

 

 

 

 

 

9001889

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

57

Image 59
Contents Washer-Extractors Page 9001889 Contents Model Identification IntroductionProgramming Setup of the MachinePress the Enter button to select options Programming Version of Control Program Storing ModeFill Explanation of the Step FunctionsProgramming Wash Chemical Hold Feature Soak Spin Example Making a New Program Cycle Heat Wash 4 10/20 Cycle Cycle Cycle 51 Spin Cycle 51 0 min Cycle 51 8 min 30 sec End Change a Complete Step Edit a CycleXxxxxxxx Changing the Time of a Step Press Enter to go to the next step Delete a Step Insert a Step Programming Delete a Cycle Reloading Previous Settings Reading Cycle Count Cycle CountCalibration of the Machine Speed Calibration Pre-Programmed Cycles Cycle Towels Light Soil Step Description Minsec Cycle Towels Medium Soil Step Description Minsec Cycle Blankets Warm Step Description Minsec Cycle Rinse and Spin Step Description Minsec Cycle Health Care Sheets Light Soil Step Description Minsec Cycle Health Care Towels Heavy Soil Step Description Minsec Cycle Health Care Cotton Blankets Step Description Minsec Cycle Health Care Personal No Bleach Step Description Minsec Cycle Health Care Pads Polyester Step Description Minsec Cycle Table Color Iron Step Description Minsec Cycle Table Color No Iron Step Description Minsec Pre-Programmed Cycles Visa No Iron Step Description Minsec Cycle Visa Color No Iron Step Description Minsec Cycle Shirt Color No Bleach Step Description Minsec Cycle Shirt Delicate Step Description Minsec Cycle Uniforms No Bleach Step Description Minsec Cycle Rags Heavy Soil Step Description Minsec Pre-Programmed Cycles Rewash/Reclaim Step Description Minsec Wash 1 18/3 32F 015 Drain 100 Pre-Programmed Cycles Energy Hot Step Description Minsec Cycle Energy Cold Step Description Minsec Pre-Programmed Cycles Normal 60C Step Description Minsec Cycle Gentle Cold Step Description Minsec Pre-Programmed Cycles Perm Press 60C Step Description Minsec Pre-Programmed Cycles Gentle 30C Step Description Minsec Inverter Drive Error Codes Indication During acceleration-If a current of more Indication