Happy Voyager
Basic Machine | 29 |
Weekly Cleaning
Every 40 hours of operation clean the area below the needle plate, including the thread cutter.
1.With the machine turned off and disconnected from the mains remove the needle plate using the offset screwdriver.
2.In the back of the machine remove the rubber cap. With the blue handled 3mm hexagonal T- driver and turn the main shaft clockwise to the “C” point, (275 degrees)
3.From the left hand side insert the manual lever and pull down and hold it in place. The turn the main shaft clockwise to the “L” point, ( 0 de- grees) to open the thread cutter.
4.Clean out any waste thread and dust from the thread cutter knife and surrounding area.