MULTITASKER

38.[RMG]

This command deletes one or all groups.

Command Format: [RMGk]

Gk = Group ID (k = # from 1-8, * for all)

Example:

Remove all cards from G52 by sending [RMG5]. The system will return the following feedback:

[G5=0]

Example 2:

Remove all cards from all groups, effectively deleting all groups, by sending [RMG*]. The system will return the following feedback:

G1-G8: EMPTY

39.[RD]

This command reads and then displays the members in a group.

Command Format: [RDGk]

Gk = Group ID (k = # from 1-8)

Example:

C2, C4, and C6 make up G5. Read the member data for G5 by sending the command [RDG5]. The system will return feedback as follows:

[G5=C2C4C6]

The feedback shows G5 and then the cards that make up G5. In this case, G5 includes C2, C4, and C6.

7.3SUMMARY OF COMMANDS Basic Commands

1)

[C]

Display card status

2)

[CnS]

Save card settings

3)

[CLR]

Restore saved settings

4)

[FRESET]

Reset to factory defaults

5)

[VER]

Display software version

6)

[HELP]

Display available commands

Feedback Commands

7)

[FBD]

Feedback delay

8)

[?]

Display system cards

9)

[?C]

Display card information

10)

[STA1]

Enable auto feedback

11)

[STA0]

Disable auto feedback

Card Control

 

12)

[IN]

Select input port

13)

[INR]

Select input and recall

14)

[MODER]

Set output resolution

15)

[BRIGHTm] Set/select brightness

16)

[BRIGHT]

Display/select brightness

17)

[CONTRm]

Set/select contrast

18)

[CONTR]

Display/select contrast

19)

[COLORm]

Set/select color

20)

[COLOR]

Display/select color

21)

[SHARPm]

Set/select sharpness

22)

[SHARP]

Display/select sharpness

23)

[HUEm]

Set/select hue

24)

[HUE]

Display/select hue

25)

[MODET]

3D comb filter

26)

[MODEN]

Noise reduction

27)

[MODEA]

Aspect ratio

28)

[FREEZ]

Freeze image

29)

[ + ]

Increment property by 1

30)

[ - ]

Decrement property by 1

ID Commands

 

31)

[RSI]

Reset Card IDs to defaults

32)

[SIDn]

Set all Card IDs

33)

[SIDnCi]

Set one Card ID

34)

[SID+]

Set all Card IDs to an offset

35)

[RSN]

Display card slot number

400-0394-007

17

Image 18
Contents MT106-103 Table of Contents Cleaning Precautions / Safety WarningsInstallation GeneralTechnical Specifications About Your MT106-103Product Description Bypass Application DiagramsDiagram 1 Typical Setup Video S Component COMPUTERVIDEO/COMPONENTDiagram 2 Internal View ScalerOperation Installing Your MT106-103Description of Commands RS-232 ControlBasic Commands NR onCnS CLR FresetFeedback Commands VERFBD Card Control STA1STA0 12.Bright ModerBRIGHTm CONTRmSharp ColorSHARPm HUEmFreez ModenModea 29. +SIDn ID CommandsRSI SIDnCiRSN Group CommandsSID+ 36. WRHelp CLRVER FBDUsing Menu Mode Menu ModeMenu Command Definitions RMCMenu Types 4 MT106-103 MenusMT106-103 Main Menu Menu Mode Examples Change Output ResolutionAdjust Brightness Altinex Policies Troubleshooting GuideLimited WARRANTY/RETURN Policies Contact Information No Display