Altinex MT106-103 manual Basic Commands, NR on, CnS

Page 9

MULTITASKER

Example: [VERC3U2]

VER = Function

C3 = Card ID or Group ID

U2 = Unit ID (optional for Unit ID 0)

For Function, see a detailed explanation under each command description.

The card ID is a unique identifier. It is equal to the enclosure slot number, or it may be an assigned value. As the slot number, the value can range from 1-4 up to 1-to-20 depending on the enclosure. If the value is assigned, the ID may be a maximum of 99. Card ID 0 (C0) is used for the controller and cannot be reassigned.

The group ID is a number representing a group of cards defined with the [WR] command. When using the group ID, all cards in the group will perform the given instruction.

NOTE: In this manual, cards will be referenced by their ID (C1, C2...C99). Typically, the ID number will be equivalent to the slot number. Groups will be referenced by their ID (G1-G8).

Changing the position of a card will significantly affect the commands recorded on software definitions or third-party control systems.

The unit ID has a value from 0 to 9. Unit ID 0 should be used for single unit operation. If the unit ID is set to zero, each command may be used without Ui. Use the command [SETU0], as explained in the MT100-100 User’s Guide.

Example:

[VERC3]:

For Unit ID Zero

[VERC3Ui]: For Unit ID other than Zero

[VERC3]: Equivalent to [VERC3U0]

BASIC COMMANDS

1.[C]

This command displays the status of the card. Command Format: [Cn]

Cn = Card ID (n = # from 1 to max slots) Example:

There is an MT106-103card in slot 4. Sending the command [C4] to the MultiTasker will yield feedback similar to the following:

Input: Composite Video

Output Resolution: 1024x768

Brightness: 24

Contrast: 40

Color: 24

Sharpness: 10

Hue: 0

3D Filter OFF

NR ON

Aspect Ratio 4:3

Freeze OFF

If there is no card in slot 4, sending the [C4] command will not return any feedback.

2.[CnS]

This command saves the card settings. This configuration will be restored after the system is reset or powered-up.

Command Format: [CnS]

Cn = Card ID (n = # from 1 to max slots) S = Save configuration

Example:

The MT106-103has been set to a resolution of 1024x768 with Composite Video as the active input. Send [C4S] and receive feedback similar to the following:

400-0394-007

8

Image 9
Contents MT106-103 Table of Contents Installation Precautions / Safety WarningsCleaning GeneralAbout Your MT106-103 Technical SpecificationsProduct Description Diagram 1 Typical Setup Application DiagramsBypass Video S Component COMPUTERVIDEO/COMPONENTScaler Diagram 2 Internal ViewDescription of Commands Installing Your MT106-103Operation RS-232 ControlBasic Commands NR onCnS Feedback Commands FresetCLR VERFBD STA0 STA1Card Control 12.BRIGHTm ModerBright CONTRmSHARPm ColorSharp HUEmModea ModenFreez 29. +RSI ID CommandsSIDn SIDnCiSID+ Group CommandsRSN 36. WRVER CLRHelp FBDMenu Command Definitions Menu ModeUsing Menu Mode RMCMenu Types 4 MT106-103 MenusMT106-103 Main Menu Menu Mode Examples Change Output ResolutionAdjust Brightness Limited WARRANTY/RETURN Policies Contact Information Troubleshooting GuideAltinex Policies No Display