Altinex MT101-115, MT101-117, MT101-114 manual Matrix Functions, Wrs=S

Page 24

MULTITASKER

After sending the command above, the contents of Subroutine 1 will be as follows:

ON1C3, ON2C3, LED1=1,ON3C3, ON4C3

MATRIX FUNCTIONS

Command Format: {WRSn=&…&}

Sn = Subroutine ID (n = # from 1 to 180)

&= Continuity of the function

NOTE: The "&" is NOT needed at the beginning or end of a function definition, and should NOT be used.

WARNING: No other functions may be defined while building a function using multiple keys. Once the controller encounters an "&", it will join the function pieces together until an end-of-function is encountered. For example, {WRS12=I1&,OFF1C4} would turn off Output 1 of C4, but the beginning of the matrix command would no longer be valid. Likewise, the following would NOT work for matrix functions:

{WRS22=&O1&,ON1C2} or

{WRS32=LED1=1,&C4}

Matrix Functions, Example 1:

Split the function for I1O2C3 into 2 different subroutines, SUB13 and SUB30. Use the following commands to connect Input 1 to Output 2 on C3:

{WRS13=I1&} and {WRS30=&O2C3}.

Press two keys to execute the function. First press Key 13 for SUB13 and then Key 30 for SUB30. The command will build as follows:

I1& + &02C3 = I1O2C3

The "&" informs the controller that the function pieces are to be joined together. When joined together, the function pieces must define a legal command or the function will be ignored.

Matrix Functions, Example 2:

Split the function for I1O2C3 into three different subroutines, S13, S30, and S11. Use the following commands:

{WRS13=I1&}

{WRS30=&O2&}

{WRS11=&C3}

Press 3 keys to execute the function. The first key pressed should be assigned to SUB13, the second to SUB30 and the third to SUB11. The command will build as follows:

I1& + &02& + &C3 = I1O2C3

The "&" informs the controller that the function pieces are to be joined together. When joined together, the function pieces must define a legal command or the function will be ignored.

NOTE: Once again, if any other commands are issued anytime before a legal command is completed, the matrix command in process will be destroyed and ignored.

51.{WRS=S}

This command allows a subroutine to call the functions stored in other subroutines instead of writing the functions to the subroutine.

Command Format: {WRSn=S1,S2...}

n

= Sub ID (n = # from 1 to 180)

S1,S2... = Sub no. (reference up to 10 subs) Example:

Set SUB100 to execute subroutines 10, 20, 30, 40, and 50 by sending the command

{WRS100=S10,S20,S30,S40,S50}. When SUB100 is executed, all the functions stored in subroutines 10, 20, 30, 40, and 50 will be executed.

400-0402-003

23

Image 24
Contents MT101-114/115/117 Table of Contents Precautions / Safety Warnings InstallationCleaning GeneralTechnical Specifications MT101-114/115/117 GeneralMT101-114/115/117 Electrical Product Description KEY Number LocationsApplication Diagrams Diagram 1 Installation InstructionsDiagram 2 Sample Matrix Setup SubroutinesAC Power Cord Before Opening the Enclosure OperationDisconnect MultiTasker Computer Control SystemPOWER-UP SUB1 U0/U1 Saving Card ConfigurationsIdentify Unit ID KEY ProgrammingRS-232 Connection 1 RS-232 Communication RS-232 ProtocolDescription of Commands RS-232 CommandsVER SETRES DFBEFB IDUiSTA1 STA012. WR RMCRate RATE=RATE=S BEEPnBaud BAUD=TXR TXMXyz 27. @xyzTest HelpLED Commands LEDn=LEDm-n ClfcSTA RDKKEY8= 8,108,0,0,0 Speakers Volume WRKClrk LockUnlk or Unlock KEY Rdlk Wrlk Clrlk RdskClrvk UplkSubroutine Commands RDSALL Subroutines are Empty WRSMatrix Functions WRS=SSUB ClrsSubroutines are Cleared WaitVER SETRES DFBTroubleshooting Guide Limited WARRANTY/RETURN Policies Contact Information Altinex PoliciesToll Free 1-800-ALTINEX