Altinex MT101-117, MT101-115, MT101-114 manual STA1, STA0, 12. WR, Rmc, Rmg, 15. RD

Page 13

MULTITASKER

10.[STA1]

This command enables automatic feedback from the cards installed in the system and affects any card with auto-feedback capability. The default at power-on or reset is STA0 or off. For more details, see the [?Cn] command definitions for individual cards.

Command Format [STA1]: = On

11.[STA0]

This command disables automatic feedback from the cards and affects any card with

auto-feedback capability. The default at power-on or reset is STA0 or off.

Command Format: [STA0]

GROUP COMMANDS

Group commands allow several cards with the same functions to be controlled simultaneously with a single command. Up to 8 groups (G1-G8) may be defined.

12.[WR]

This command adds cards to a group. In MultiTasker systems with audio and video cards, the groups are typically as follows:

Group 1 = Video Cards

Group 2 = Audio Cards

Group 3 = Video and Audio Cards

Command Format: [WRCn1Cn2…Gk]

Cn = Card ID (n = slot # from 1 to max slots)

Gk = Group ID (k = # from 1-8)

Example:

Add C2, C4, and C6 to G5 by sending the command [WRC2C4C6G5]. After executing this command, G5 will consist of C2, C4, and C6.

Now add C8 to G5 by sending [WRC8G5]. C8 is added to G5, and G5 is not overwritten. View the contents of G5 by sending [RDG5] and receiving the following feedback:

[G5=C2C4C6C8]

13.[RMC]

This command removes one or more cards from a group.

Command Format: [RMCn1Cn2…Gk] Cn = Card ID (n= # from 1 to max slots)

Gk = Group ID (k = # from 1-8)

Example:

G5 consists of the C2, C4, C6, and C8. Remove C6 and C8 by sending [RMC6C8G5]. View the contents of G5 by sending [RDG5] and receiving the following feedback:

[G5=C2C4]

14.[RMG]

This command deletes one or all groups.

Command Format: [RMGk]

Gk = Group ID (k = # from 1-8, * for all)

Example:

Remove all cards from G52 by sending [RMG5]:

[G5=0]

Example 2:

Remove all cards from all groups, effectively deleting all groups, by sending [RMG*]. The system will return the following feedback:

G1-G8: EMPTY

15.[RD]

This command reads and then displays the members in a group.

Command Format: [RDGk]

Gk = Group ID (k = # from 1-8)

Example:

C2, C4, and C6 make up G5. Read the member data for G5 by sending the command [RDG5]:

[G5=C2C4C6]

The feedback shows G5 and then the cards that make up G5. In this case, G5 includes C2, C4, and C6.

400-0402-003

12

Image 13
Contents MT101-114/115/117 Table of Contents Installation Precautions / Safety WarningsCleaning GeneralMT101-114/115/117 General Technical SpecificationsMT101-114/115/117 Electrical KEY Number Locations Product DescriptionDiagram 1 Installation Instructions Application DiagramsSubroutines Diagram 2 Sample Matrix SetupOperation AC Power Cord Before Opening the EnclosureDisconnect MultiTasker Computer Control SystemSaving Card Configurations POWER-UP SUB1 U0/U1Identify Unit ID KEY ProgrammingRS-232 Protocol RS-232 Connection 1 RS-232 CommunicationRS-232 Commands Description of CommandsVER SETDFB RESEFB IDUiSTA0 STA112. WR RMCRATE= RateRATE=S BEEPnBAUD= BaudTXR TXM27. @xyz XyzTest HelpLEDn= LED CommandsLEDm-n ClfcRDK STAWRK KEY8= 8,108,0,0,0 Speakers VolumeLock ClrkUnlk or Unlock KEYWrlk RdlkClrlk RdskUplk ClrvkRDS Subroutine CommandsALL Subroutines are Empty WRSWRS=S Matrix FunctionsClrs SUBSubroutines are Cleared WaitSET VERRES DFBTroubleshooting Guide Altinex Policies Limited WARRANTY/RETURN Policies Contact InformationToll Free 1-800-ALTINEX