Altinex MT101-117, MT101-115, MT101-114 manual Xyz, 27. @xyz, Test, Help

Page 16

MULTITASKER

Example:

Send the text string "HELLO" to the RS-232 bus. The string will be ignored by the MultiTasker, but not the unit receiving the command. Additionallly, it will add opening and closing brackets. To do this, send the command [TXMHELLO] and the following will be sent to the RS-232 bus:

[HELLO]

26.<x[y]z>

This command is used to send ISM5000 command strings to the RS-232 bus through the MultiTasker. It transmits the “< >” symbols with the command string and allows bracket commands within the command string.

Command Format: <x[y]z>

x[y]z = text string ("a[b]c" or "1[2]3" or…)

Example:

Send the command string "<abc[123]xyz>" to the RS-232 bus. The string will be ignored by the MultiTasker, but not the unit receiving the command. Additionallly, it will add opening and closing brackets. To do this, send the command <abc[123]xyz> and the following will be sent to the RS-232 bus:

<abc[123]xyz>

27.<@x[y]z>

This command is used to send ISM5000 command strings to the RS-232 bus, through the MultiTasker. It removes the “< >” symbols in the command string and allows bracket commands within the command string.

Command Format: <x[y]z>

x[y]z = text string ("a[b]c" or "1[2]3" or…)

Example:

Send the command string "abc[123]xyz" to the RS-232 bus. The string will be ignored by the MultiTasker, but not the unit receiving the command. Additionallly, it will remove the opening and closing brackets. To do this, send the command <@abc[123]xyz> and the following will be sent to the RS-232 bus:

abc[123]xyz

28.[TEST]

This command performs a non-destructive test of the internal memory.

Command Format: [TEST]

Example:

In order to test the MultiTasker internal memory, send the command [TEST]. The system will respond as follows if the test passes:

[ ] [ ]

Otherwise, failures will be indicated.

29.[HELP]

This command displays information available for the MultiTasker interface commands or card commands. Sending the command without a card reference returns help for the interface.

Command Format: [HELPCn], [HELPUi]

Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 20)

Example 1:

In order to view the RS-232 commands available for the MultiTasker, send the command [HELP]. The commands along with a brief description will be displayed in the Terminal Window.

Example 2:

In order to view the RS-232 commands available for C2, send the command [HELPC2]. The commands along with a brief description will be displayed in the Terminal Window.

400-0402-003

15

Image 16
Contents MT101-114/115/117 Table of Contents Precautions / Safety Warnings InstallationCleaning GeneralMT101-114/115/117 General Technical SpecificationsMT101-114/115/117 Electrical Product Description KEY Number LocationsApplication Diagrams Diagram 1 Installation InstructionsDiagram 2 Sample Matrix Setup SubroutinesAC Power Cord Before Opening the Enclosure OperationDisconnect MultiTasker Computer Control SystemPOWER-UP SUB1 U0/U1 Saving Card ConfigurationsIdentify Unit ID KEY ProgrammingRS-232 Connection 1 RS-232 Communication RS-232 ProtocolDescription of Commands RS-232 CommandsVER SETRES DFBEFB IDUiSTA1 STA012. WR RMCRate RATE=RATE=S BEEPnBaud BAUD=TXR TXMXyz 27. @xyzTest HelpLED Commands LEDn=LEDm-n ClfcSTA RDKKEY8= 8,108,0,0,0 Speakers Volume WRKClrk LockUnlk or Unlock KEYRdlk WrlkClrlk RdskClrvk UplkSubroutine Commands RDSALL Subroutines are Empty WRSMatrix Functions WRS=SSUB ClrsSubroutines are Cleared WaitVER SETRES DFBTroubleshooting Guide Altinex Policies Limited WARRANTY/RETURN Policies Contact InformationToll Free 1-800-ALTINEX