Chapter 1. Introduction
When combined with the supported ATLAS 800 Series base units and, optionally, one or more Quad T1/PRI or T3 Modules, the NxT1 HSSI/V.35 Module can implement
FUNCTIONAL DESCRIPTION
The NxT1 HSSI/V.35 Module installs in any available option slot in the supported ATLAS 800 Series units. You can view the status of the module itself, as well as the circuits to which it interfaces, from the front panel (ATLAS 800PLUS only). Additional status information is available via the terminal menus, accessible through either a
FEATURES
Features of the NxT1 HSSI/V.35 Module are listed here:
•Standard
•Optional V.35 interface using adapter cable (ADTRAN P/N 3125I081)
•Hot swappable
•Maximum distance 6,000 feet
NXT1 HSSI/V.35 MODULE SPECIFICATIONS
Each T1 port of the NxT1 HSSI/V.35 Module conforms to the following specifications:
Line Rate
1.544 Mbps ± 75 bps
Framing
D4, SF or ESF per ANSI t1.403 and AT& T TR 54016
Line Coding
•B8ZS (Bipolar Eight Zero Substitution)
•AMI (Alternate Mark Inversion)
Alarms
Loss of Signal (LOS), Red, Yellow, Blue
20 | NxT1 HSSI/V.35 Module User Manual |