Chapter 3. Operation
T1 MENUS | Read Security: 5 |
| Provides information about the four T1 interfaces located on the NxT1 |
| HSSI Option Module. This menu is only visible when T1 ENABLE is set to |
| ENABLED. |
| ALARMS |
| Read security: 5 |
| Displays an alarm condition on the ATLAS 550 unit. Press <Enter> to |
| access this menu item. |
LOS
Indicates a loss of signal detected on port interface.
RED
Indicates inability to frame data received on the port. Alternately referred to as Out of Frame (OOF).
YELLOW
Receiving remote alarm (RAI) on port.
BLUE
Receiving unframed all ones from the port Alarm Indicator Signal (AIS).
DS0 ALARM
Displays
RX LEVEL
(Receive Level) Indicates the strength of the signal (in dB) received on the port.
PERFORMANCE
Write security: 3; Read security: 5
The performance fields (either current,
PRT
Displays the port number
CLR
Clears performance information for the selected port
ES
Errored Second (ES) is a second with one or more error events OR one or more Out Of Frame events OR one or more Controlled Slips
BES
Bursty Errored Second (BES) is a second with more than one, but less than 320 error events