ADTRAN NxT1 HSSI/V.35 user manual Wiring, Usoc RJ-48C

Page 25

Chapter 2. Installation

WIRING

Each module T1 port uses a single RJ-48C jack to connect to a T1 circuit. Table 2-1shows the T1 pinout connection. The required wiring connection follows:

Connector Type

(USOC) RJ-48C

 

 

 

Table 2-1. T1 Pinout Connection

 

 

 

PIN

NAME

DESCRIPTION

 

 

 

1

R1 RXDATA

Receive data from the network ring

2

T1 RXDATA

Receive data from the network tip

3, 6, 7, 8

Unused

 

n/ a

4

R TXDATA

Send data towards the network ring

5

T TXDATA

 

Send data towards the network tip

The HSSI/V.35 interface uses a single SCSI-II 50 pin connector with an op- tional V.35 adapter cable. Table 2-2 shows the SCSI-II connector pinout.

Connector Type

50 pin SCSI-II Female

 

 

Table 2-2. HSSI/V.35 (SCSI-50) Pinout

 

 

 

 

PIN (+ side)

PIN (- side)

DIRECTION

DESCRIPTION

 

 

 

 

1

26

HSSI SG - Signal Ground

2

27

O

HSSI RT - Receive Timing

3

28

O

HSSI CA - DCE Available

4

29

O

HSSI RD - Receive Data

5

30

O

HSSI LC - Loopback Circuit C

6

31

O

HSSI ST - Send Timing

7

32

HSSI SG - Signal Ground

8

33

I

HSSI TA - DTE Available

9

34

I

HSSI TT - Terminal Timing

10

35

I

HSSI LA - Loopback Circuit A

11

36

I

HSSI SD - Send Data

12

37

I

HSSI LB - Loopback Circuit B

13

38

HSSI SG - Signal Ground

61200771L1-1

NxT1 HSSI/V.35 User Manual

25

Image 25
Contents NxT1 HSSI/V.35 Module Page Save These Important Safety Instructions Affidavit Requirements for Connection to Digital Services Page Page SOC REN FIC Usoc Page Page Limited Product Warranty Customer Service, Product Support Information, and Training Post-Sale Support Table of Contents Appendix a Dedicated Maps Configuration List of Tables List of Tables Figure A-1 Dedicated Maps Menu List of FiguresList of Figures NXT1 HSSI/V.35 Module Overview IntroductionNXT1 HSSI/V.35 Module Specifications FeaturesFunctional Description Line or payload loopback Local and Remote NxT1 HSSI/V.35 Option Module Physical DescriptionBefore Installing the NXT1 HSSI/V.35 Module InstallationInstalling the NXT1 HSSI/V.35 Module Usoc RJ-48C WiringFailed Self-Test Operation Alarms Power UP and InitializationOverview OperationTerminal Menu Structure Modules Write security 3 Read security Read securityModules/Menu on Nor has a module been manually enabled for this option slot Sembly revision Displays the assembly revisionDisplays the part number of the module Displays the serial number of the moduleAccess this menu item Write security 2 Read security Option Module Write security 4 Read securityFunctionality between the DTE and the T1 interfaces Read Security 5 Write SecurityLA and LB RX Rate and TX Rate Restore Atlas Features Used with NXT1 HSSI/V.35 Module OptionsOperation Write security3 Read security5 Appendix a Dedicated Maps ConfigurationCREATE/EDIT Maps Write security3 Read security5 Read security5Security level 3 Read security Write security3 Read securityMenus NXT1 HssiT1 Trouble Code Service Appendix A. Dedicated Maps Configuration Index Index Index-48