ADTRAN 3060 specifications General, Adtran Total Access 3010 LTU

Page 1

Section 61182007L1-5A

Issue 1, June 2001

Total Access® 3010 LTU

High-bit-rate Digital Subscriber Line

Transceiver Unit for the Central Office

Installation and Maintenance

CONTENTS

 

1.

GENERAL

1

2.

INSTALLATION

2

3.

OPERATION

3

4.

HDSL SYSTEM TESTING

4

5.

SCU CONTROL PORT OPERATION (HDSL)

5

6.

HDSL DEPLOYMENT GUIDELINES

17

7.

MAINTENANCE

17

8.

PRODUCT SPECIFICATIONS

17

1182007L1LTU

PWR G703

TST LP1 LP2

ALM

9. WARRANTY AND CUSTOMER SERVICE

................... 17

Appendix A.

HDSL H-LSS Circuit Configuration and Turnup

 

 

for G.703 Fed Systems

A-1

Appendix B.

HDSL H-LSS Circuit Configuration and Turnup

 

 

for DS3-Fed Systems

B-1

FIGURES

 

 

Figure 1. ADTRAN Total Access 3010 LTU

1

Figure 2. LTU Edge Connector Wiring

2

Figure 3. LTU Span Powering Diagram

4

Figure 4.

HDSL Loopbacks

5

Figure 5. RS-232 (DB-9) Pin Assignments

5

Figure 6.

Logon Screen

7

Figure 7.

Total Access Screen

7

Figure 8. Access Module Menus Screen

8

Figure 9.

HDSL Main Menu Screen

9

TX

E

Q

RX

TX

M

O

N

RX

ACT

GRN = NORM

YEL = MAN

A P S

Figure 10.

Configuration Screen

9

Figure 11.

Provisioning Screen

10

Figure 12. Network Source Screen

10

Figure 13.

Status Screen

11

Figure 14. REG #1 Status Screen

11

Figure 15.

Alarms Screen

12

Figure 16.

Test Screen

13

Figure 17. Performance History Screen

13

Figure 18.

Protection Configuration Screen – Main

14

Figure 19.

Protection Configuration Screen – Auxiliary

14

Figure 20. Set Circuit ID Screen

16

Figure 21. Alarm Option Screen

17

TABLES

 

 

Table 1. Faceplate LED Indicators

3

Table 2.

Screen Abbreviations

6

Table 3.

LP1 and LP2 Guidellines

12

Table 4.

Protection Configuration Option Settings

15

Table 5.

Total Access 3010 LTU Specifications

18

Table B-1.

Faceplate LED Indicator

B-2

1. GENERAL

The ADTRAN Total Access 3010 HDSL Transceiver Unit for the Central Office (LTU), part number 1182007L1, is the Central Office (CO) unit used to deploy an HDSL E1 circuit using 4-wire metallic facilities. See Figure 1.

Figure 1. ADTRAN Total Access 3010 LTU

The E1 input signal is supplied from the network via individual G.703 lines or an E3 multiplexer. The HDSL signals are provided to the local loop. The Total Access 3010 LTU works in conjunction with the ADTRAN NTU and REG to provide an E1 service up to 9.4 km on the local loop.

The LTU works with multiple list versions of the HDSL unit Remote end (NTU) and HDSL Range Extender (REG) as listed below:

1245043Lx Low Voltage T400 REG

1245031Lx, Low Voltage T200 NTU

1245033Lx, Nx64 NTU

1245044L3, 4th Gen - T400 NTU

1245035Lx, 5th Gen - T200 NTU

The Total Access 3010 LTU can be deployed in circuits consisting of one LTU and one NTU or in a protection configuration requiring two LTUs and two NTUs. When deployment requires the HDSL Range Extender (REG), this LTU can be deployed with one or two REGs and one NTU.

61182007L1-5A

Trademarks: Any brand names and product names included in this document are

1

 

trademarks, registered trademarks, or trade names of their respective holders.

 

Image 1
Contents General Adtran Total Access 3010 LTURevision History InstallationLTU Alarm Outputs Powering OptionsFaceplate Indicators Faceplate LED IndicatorsHdsl System Testing SCU Control Port Operation Hdsl Display Off ModeFront Panel Screen Abbreviations MenusMajor Minor Major Minor InfoLTU Access Module Menus ScreenREG1 NTUREG2 CRC4 CASHDB3 LTU E1 HDB3 Enabled CRC4CAS HDB3 CFMLP1 and LP2 Guidellines No Alarm Conditions LTU REG NTUNET Cust NET Cust LP2 LTU LP1 REG NTUES SES UAS BPV SES UAS BPVProtection Configuration Screen Main Protection Options Settings Description Protection Configuration Option SettingsSet Circuit ID Screen Hdsl Deployment Guidelines MaintenanceTotal Access 3000 LTU Specifications Product SpecificationsWarranty and Customer Service L1-5, Issue Install the LTUs Into Total Access Prerequisite ProceduresIntroduction Materials RequiredInstall the NTU Install the DUAL-SLOT Standalone HousingDisabling Protection Switching Reset ALL Equipment to Operating ConditionDisabling Protection Switching Adjust Wiring at Dual Remote HousingL1-5, Issue Install the DS3 MUX Modules Unpack and Inspect the the Total Access DS3 MUX ModulesProvision the DS3 MUX Table B-1. Faceplate LED IndicatorsProvision the LTU Install the LTUInstall the NTU into the Dual-Slot Remote Housing 61182007L1-5A L1-5, Issue L1-5, Issue