ADTRAN 3060 specifications Install the DUAL-SLOT Standalone Housing, Install the NTU

Page 22

If this is an initial installation, the units will require provisioning to appropriately configure them out of the factory default states.

2.1Logon to Total Access system.

2.2Check to ensure the LTU line cards are correctly provisioned according to circuit parameters. Under the Provisioning menu, set numbered option, Network Source, to G.703. This option causes the LTU to look to the individual G.703 backplane connector for its data feed.

2.3Ensure the provisioning of both the

MAIN and AUX LTUs is identical, except for the following options:

a.Provision the MAIN unit to OUT OF SERVICE-MAINTENANCE(OOS-M)mode.

b.Provision the AUX unit to the OUT OF SERVICE-UNASSIGNED(OOS-U) mode.

2.4Enable protection switching

a.Access the MAIN Menu of the LTU in the odd-numbered (MAIN) slot.

b.Select Option 7, Protection Configuration.

c.Select Option 1, Protection Mode.

d.To enable protection switching, select Option 1, ENABLE.

NOTE

Unless the AUX circuit is in the OOS-U mode, the operator will not be able to change the Protection mode of the MAIN LTU.

e.Set Options 2 and 3, BER Threshold and BER Interval (see Table 3 in the Installation and Maintenance practice for definitions).

f.Back out of the menu for the MAIN slot and access the LTU in the even-numbered (AUX) slot.

g.Select Option 7, Protection Configuration.

h.Option 1, Protection Mode, will have been set to AUTO. If you desire to provision a different H-LSS mode, select Option 1, and choose between Auto, Manual AUX, Manual Main, and Auto Hold.

i.Set Options 2-7 as desired on the AUX unit.

2.5From the provisioning menu of the AUX circuit, reset the AUX unit to OOS-M.

2.6Logoff the system

a.From the Total Access Menu, select Option 7, Logoff, and press <Enter>.

b.From the Exit and Logoff screen, select “Y” and press <Enter>.

3.INSTALL THE DUAL-SLOT STANDALONE HOUSING

See the associated Installation and Maintenance practice, P/N 61245034L2-5, for mounting and wiring instructions.

4. INSTALL THE NTU

The NTU terminates local loop HDSL signals originating from the Central Office (CO) unit and transforms the HDSL signal into traditional G.703 signals to be delivered to the customer.

4.1Install the NTU into the Dual-Slot Remote Housing

Electronic modules can be damaged by static electrical discharge. Before handling modules, wear an antistatic discharge wrist strap to prevent damage to electronic components. Place modules in antistatic packing material when transporting or storing. When working on modules, always place them on an approved antistatic mat that is electrically grounded.

4.1.1Connect the individual 4-wire HDSL circuits to the HDSL terminal block inside the Dual slot remote housing.

The 4-wire MAIN circuit will connect to the Loop 1 and Loop 2 terminals labeled “MAIN” and the 4-wire AUX circuit will connect to the Loop 1 and Loop 2 terminals labeled “AUX.”

4.1.2Gently but firmly push the NTU into the lower dual slot remote housing slot. Repeat this step for the second NTU in the upper slot.

4.1.3The LTUs will transfer provisioning data to the NTUs upon power up. Some provisioning of the NTU, however, may be necessary due to hardware DIP switches and jumpers. See the Installation and Maintenance practice for the specific NTU utilized by your company.

A-2

Section 61182007L1-5, Issue 1

61182007L1-5A

Image 22
Contents Adtran Total Access 3010 LTU GeneralInstallation Revision HistoryFaceplate Indicators Powering OptionsLTU Alarm Outputs Faceplate LED IndicatorsHdsl System Testing SCU Control Port Operation Hdsl Display Off ModeFront Panel Menus Screen AbbreviationsMajor Minor Info Major MinorAccess Module Menus Screen LTUREG1 NTUREG2 CRC4 CASHDB3 CAS HDB3 HDB3 Enabled CRC4LTU E1 CFMLP1 and LP2 Guidellines No Alarm Conditions LTU REG NTUNET Cust ES SES UAS BPV LTU LP1 REG NTUNET Cust LP2 SES UAS BPVProtection Configuration Screen Main Protection Configuration Option Settings Protection Options Settings DescriptionSet Circuit ID Screen Maintenance Hdsl Deployment GuidelinesProduct Specifications Total Access 3000 LTU SpecificationsWarranty and Customer Service L1-5, Issue Introduction Prerequisite ProceduresInstall the LTUs Into Total Access Materials RequiredInstall the DUAL-SLOT Standalone Housing Install the NTUDisabling Protection Switching Reset ALL Equipment to Operating ConditionDisabling Protection Switching Adjust Wiring at Dual Remote HousingL1-5, Issue Unpack and Inspect the the Total Access DS3 MUX Modules Install the DS3 MUX ModulesTable B-1. Faceplate LED Indicators Provision the DS3 MUXInstall the LTU Provision the LTUInstall the NTU into the Dual-Slot Remote Housing 61182007L1-5A L1-5, Issue L1-5, Issue