ADTRAN 3060 specifications Protection Configuration Screen Main

Page 14

The Protection Configuration Screen - Main, illustrated in Figure 18, displays the current settings for Protection Mode, BER Threshold and BER Interval. The BER Threshold allows the user to select a bit error rate that, when exceeded, will cause a switchover to an auxiliary circuit. The BER Interval defines the interval over which errors will be accumulated for comparison with the BER Threshold.

The option settings for BER Threshold and BER Interval are detailed in Table 4.

The Protection Configuration Screen – Auxiliary, illustrated in Figure 19, displays the current settings for Protection Mode, Minimum Hold-in Time, BER Threshold, BER Interval, Lock-in Hours, Switch-to -Aux Limit, and Lock-in Check Interval. A History count for Switchovers, Reversions, Failures, and Lockouts is provided, while the Lock-in Options and

 

Shelf:

1

Slot:

5

 

Total Access System

04/07/01 09:19

 

Unacknowledged Alarms:

MAJOR MINOR

 

 

 

Circuit ID:

 

 

 

 

 

 

 

 

 

 

 

Protection Configuration

 

 

 

 

 

 

1.

Protection Mode

Disabled

 

 

 

 

 

2.

BER Threshold

1E-4

 

 

 

 

 

 

3.

BER Interval

15

Min(s)

 

 

 

 

 

 

Selection:

 

 

 

 

 

 

 

 

‘?’ - System Help Screen

 

 

 

 

 

 

 

 

Figure 18. Protection Configuration Screen – Main

 

 

 

 

 

 

 

 

 

Shelf:

1

Slot:

6

 

Total Access System

04/07/01 09:20

 

Unacknowledged Alarms:

 

MAJOR MINOR

 

 

 

Circuit ID:

 

 

 

 

 

 

 

 

 

 

 

 

Protection Configuration

 

 

 

 

 

1.

Protection Mode

Manual Disable

 

 

 

 

2.

Minimum Hold-in Time

01

minutes

 

 

 

 

3.

BER Threshold

1E-4

 

 

 

 

 

4.

BER Interval

15

minutes

 

 

 

 

5.

Lock-in Time

12

hours

 

 

 

 

6.

Switch-to-Aux Limit

03

(1-9)

 

 

 

 

7.

Lock-in Check Interval

20

minutes

Current System Status

 

History

 

[ Prot Disabled ]

Switchovers:

00

Reversions:

00

 

Failures:

00

Lockouts:

00

Current Lock-in Option Setting

Lock-in for 12 hours if 03 switchovers occur in 20 minutes.

Selection:

‘?’ - System Help Screen

Figure 19. Protection Configuration Screen – Auxiliary

14

Section 61182007L1-5, Issue 1

61182007L1-5A

Image 14
Contents Adtran Total Access 3010 LTU GeneralInstallation Revision HistoryFaceplate Indicators Powering OptionsLTU Alarm Outputs Faceplate LED IndicatorsHdsl System Testing Front Panel Display Off ModeSCU Control Port Operation Hdsl Menus Screen AbbreviationsMajor Minor Info Major MinorAccess Module Menus Screen LTUREG2 NTUREG1 HDB3 CASCRC4 CAS HDB3 HDB3 Enabled CRC4LTU E1 CFMNET Cust No Alarm Conditions LTU REG NTULP1 and LP2 Guidellines ES SES UAS BPV LTU LP1 REG NTUNET Cust LP2 SES UAS BPVProtection Configuration Screen Main Protection Configuration Option Settings Protection Options Settings DescriptionSet Circuit ID Screen Maintenance Hdsl Deployment GuidelinesProduct Specifications Total Access 3000 LTU SpecificationsWarranty and Customer Service L1-5, Issue Introduction Prerequisite ProceduresInstall the LTUs Into Total Access Materials RequiredInstall the DUAL-SLOT Standalone Housing Install the NTUDisabling Protection Switching Reset ALL Equipment to Operating ConditionDisabling Protection Switching Adjust Wiring at Dual Remote HousingL1-5, Issue Unpack and Inspect the the Total Access DS3 MUX Modules Install the DS3 MUX ModulesTable B-1. Faceplate LED Indicators Provision the DS3 MUXInstall the LTU Provision the LTUInstall the NTU into the Dual-Slot Remote Housing 61182007L1-5A L1-5, Issue L1-5, Issue