Figure 21 illustrates the Alarm Options Screen. This option allows the user to first set a 15-minute threshold for both ES and SES alarms and subsequently to categorize the crossing of those thresholds as a MINOR or MAJOR alarm. Setting a threshold to 900 will disable it.

6. HDSL DEPLOYMENT GUIDELINES

The ADTRAN HDSL system is designed to provide E1 services over loops designed to comply with ETSI guidelines. Deployment guidelines are given below.

1.All loops are non-loaded only.

2.For loops with 0.4 mm cable, the maximum loop length including bridged tap lengths is 2.7 km.

3.For loops with 0.5 mm cable, the maximum loop length including bridged tap lengths is 4.7 km.

4.Any single bridged tap is limited to 500 m.

5.Maximum number of bridged taps is 2.

7. MAINTENANCE

The ADTRAN Total Access LTU requires no routine maintenance. In case of equipment malfunction, use the faceplate Bantam jack connectors to help locate the source of the problem.

ADTRAN does not recommend that repairs be performed in the field. Repair services may be obtained by returning the defective unit to the ADTRAN Customer Service RMA Department.

Shelf: 1 Slot: 5

Total Access System

04/07/01 09:22

Unacknowledged Alarms:

MAJOR MINOR

 

 

Circuit ID:

 

 

 

 

Alarm Options

Current Settings

1.

ES Alarm Level

=

Major

2.

SES Alarm Level

=

Major

3.

ES Alarm Threshold

=

000

4.

SES Alarm Threshold

=

000

Selection:

‘?’ - System Help Screen

Figure 21. Alarm Options Screen

61182007L1-5A

Section 61182007L1-5, Issue 1

17

Image 17
Contents General Adtran Total Access 3010 LTURevision History InstallationLTU Alarm Outputs Powering OptionsFaceplate Indicators Faceplate LED IndicatorsHdsl System Testing Front Panel Display Off ModeSCU Control Port Operation Hdsl Screen Abbreviations MenusMajor Minor Major Minor InfoLTU Access Module Menus ScreenREG2 NTUREG1 HDB3 CASCRC4 LTU E1 HDB3 Enabled CRC4CAS HDB3 CFMNET Cust No Alarm Conditions LTU REG NTULP1 and LP2 Guidellines NET Cust LP2 LTU LP1 REG NTUES SES UAS BPV SES UAS BPVProtection Configuration Screen Main Protection Options Settings Description Protection Configuration Option SettingsSet Circuit ID Screen Hdsl Deployment Guidelines MaintenanceTotal Access 3000 LTU Specifications Product SpecificationsWarranty and Customer Service L1-5, Issue Install the LTUs Into Total Access Prerequisite ProceduresIntroduction Materials RequiredInstall the NTU Install the DUAL-SLOT Standalone HousingDisabling Protection Switching Reset ALL Equipment to Operating ConditionDisabling Protection Switching Adjust Wiring at Dual Remote HousingL1-5, Issue Install the DS3 MUX Modules Unpack and Inspect the the Total Access DS3 MUX ModulesProvision the DS3 MUX Table B-1. Faceplate LED IndicatorsProvision the LTU Install the LTUInstall the NTU into the Dual-Slot Remote Housing 61182007L1-5A L1-5, Issue L1-5, Issue