ADTRAN 3060 specifications 61182007L1-5A L1-5, Issue

Page 29

NOTE

Ensure that data has been removed from the AUX circuit before proceeding with the next step. Disabling protection switching before removing data from the AUX loop will cause a loss of signal condition on that loop. Under normal circumstances, the data on the H-LSS circuit will be running on the MAIN HDSL circuit, and this precaution is unnecessary.

7.0.1Disabling protection switching.

a.Access the AUX LTU and select Option 2, Provisioning, from the HDSL Main Menu.

b.From the Provisioning Menu, choose the Service State option.

c.Select Option 3, Out Of Service-Unassigned.

d.Escape out of the AUX LTU menus and proceed to the MAIN LTU Menu.

e.From the Main Menu, select Option 7, Protection Configuration.

f.From the Protection Configuration menu, select Option 1, Protection Mode.

g.Choose Option 2, Disable.

NOTE

There is no provisioning required at the NTUs to remove protection switching capability. Upon completion of the above procedure, the MAIN circuit is an independent, non-protected HDSL circuit. The AUX circuit is also now independent, with protection switching disabled, and currently OOS-U.

7.0.2Adjust wiring at Dual remote housing. Once protection switching has been disabled in the LTUs, the housing is internally wired to provide an E1signal to both the MAIN E1 and AUXILIARY/TEST E1 RJ-48 jacks. Connect the customer’s equipment to the AUX RJ-48 jack or the AUX E1 terminal strip in the housing to complete a second independent HDSL circuit.

NOTE

G.703 DS3 multiplexer channel mapping to the even-numbered (formerly AUX) slot in the Total Access 3010 chassis will not automatically be restored. Assignment of an embedded G.703 in the DS3 data stream to the even slot will have to be made prior to using the slot as a DS3-fed HDSL circuit.

61182007L1-5A

Section 61182007L1-5, Issue 1

B-5

Image 29
Contents General Adtran Total Access 3010 LTURevision History InstallationLTU Alarm Outputs Powering OptionsFaceplate Indicators Faceplate LED IndicatorsHdsl System Testing Front Panel Display Off ModeSCU Control Port Operation Hdsl Screen Abbreviations MenusMajor Minor Major Minor InfoLTU Access Module Menus ScreenREG2 NTUREG1 HDB3 CASCRC4 LTU E1 HDB3 Enabled CRC4CAS HDB3 CFMNET Cust No Alarm Conditions LTU REG NTULP1 and LP2 Guidellines NET Cust LP2 LTU LP1 REG NTUES SES UAS BPV SES UAS BPVProtection Configuration Screen Main Protection Options Settings Description Protection Configuration Option SettingsSet Circuit ID Screen Hdsl Deployment Guidelines MaintenanceTotal Access 3000 LTU Specifications Product SpecificationsWarranty and Customer Service L1-5, Issue Install the LTUs Into Total Access Prerequisite ProceduresIntroduction Materials RequiredInstall the NTU Install the DUAL-SLOT Standalone HousingDisabling Protection Switching Reset ALL Equipment to Operating ConditionDisabling Protection Switching Adjust Wiring at Dual Remote HousingL1-5, Issue Install the DS3 MUX Modules Unpack and Inspect the the Total Access DS3 MUX ModulesProvision the DS3 MUX Table B-1. Faceplate LED IndicatorsProvision the LTU Install the LTUInstall the NTU into the Dual-Slot Remote Housing 61182007L1-5A L1-5, Issue L1-5, Issue