ADTRAN 3060 specifications LTU LP1 REG NTU, NET Cust LP2, Es Ses Uas Bpv

Page 13

At each 15-minute interval, the performance information is transferred to the 15-minute performance data register accessed from the Performance History screen. At each 24-hour interval, the performance data is transferred into the 24-hour performance data register also accessed using the Performance History screen. The Performance History screen is shown in Figure 17.

Type the corresponding number to view the Performance History data for customer or network loops.

From the Status Screen, type “1” to reset the current performance registers to zero on the Status and Performance History Screens.

Shelf: 1

Slot:

5

 

Total Access System

 

 

04/07/01 09:16

Unacknowledged Alarms:

 

MAJOR MINOR

 

 

 

 

Circuit ID:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Test

 

 

 

 

 

 

 

 

1.

Selftest

 

 

 

 

 

 

 

 

 

 

2.

Loopback to Network

at LTU

= Inactive

 

 

 

 

3.

Loopback to Customer at LTU

= Inactive

 

 

 

 

4.

Loopback to Network

at NTU

= Inactive

 

 

 

 

5.

Loopback to Customer at NTU

= Inactive

 

 

 

 

6.

Loopback to Network

at REG-1 = Inactive

 

 

 

 

7.

Loopback to Network

at REG-2 = Inactive

 

 

 

_____

 

_____

 

 

_____

 

_____

 

 

LTU

LP1

REG 1

LP1

REG 2

LP1

NTU

 

 

--->-----

<=====>-----

<=====>-----

<=====>-----<—-

 

 

 

 

 

 

 

NET

 

 

 

CUST

 

 

LP2

LP2

LP2

 

 

<--------

<=====>-----

<=====>-----

<=====>-----—>

 

 

_____

 

_____

 

_____

 

_____

 

 

 

 

 

Selection:

 

 

 

 

 

 

 

 

‘?’ - System Help Screen

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 16. Test Screen

 

 

 

 

 

 

 

 

 

 

 

 

Shelf:

1

Slot:

5

 

Total Access System

 

 

 

04/07/01 09:17

Unacknowledged Alarms:

 

MAJOR MINOR

 

 

 

 

 

Circuit ID:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LTU G.703 Performance Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

Minute History

 

 

 

 

 

Current Error Regs

 

 

 

ES SES UAS BPV

 

Menu

 

 

ES

 

SES

UAS

BPV

09:15

000 000 000 000

1.

LTU G.703

 

15 Min: 000

 

000

000

000

09:00 --- --- --- ---

2.

LTU Loop 1

 

24 Hr: 00000 00000 00000 00000

08:45 --- --- --- ---

3.

LTU Loop 2

 

 

 

 

 

 

 

 

08:30

--- --- --- ---

4.

NTU G.703

 

 

 

 

 

 

 

 

08:15

--- --- --- ---

5.

NTU Loop 1

 

 

24 Hour History

 

 

08:00 --- --- --- ---

6.

NTU Loop 2

 

 

ES

 

SES

UAS

BPV

 

07:45 --- --- --- ---

7.

REG1 NET Lp1

 

09/21

-----

----- ----- -----

 

07:30 --- --- --- ---

8.

REG1 NET Lp2

 

09/20

-----

----- ----- -----

 

07:15 --- --- --- ---

9.

REG1 CST Lp1

 

09/19

-----

----- ----- -----

 

07:00 --- --- --- ---

10. REG1 CST Lp2

 

09/18

-----

----- ----- -----

 

06:45 --- --- --- ---

11. REG2 NET Lp1

 

09/17

-----

----- ----- -----

 

06:30 --- --- --- ---

12. REG2 NET Lp2

 

09/16

-----

----- ----- -----

 

06:15 --- --- --- ---

13. REG2 CST Lp1

 

09/15

-----

----- ----- -----

 

06:00 --- --- --- ---

14. REG2 CST Lp2

 

 

 

 

 

 

 

 

05:45

--- --- --- ---

 

 

 

 

 

 

 

 

 

 

 

05:30

--- --- --- ---

B.

Page back

 

 

Selection:

 

 

 

 

Page 1

F.

Page forward

‘?’ - System Help Screen

 

most recent data

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 17. Performance History Screen

61182007L1-5A

Section 61182007L1-5, Issue 1

13

Image 13
Contents General Adtran Total Access 3010 LTURevision History InstallationLTU Alarm Outputs Powering OptionsFaceplate Indicators Faceplate LED IndicatorsHdsl System Testing SCU Control Port Operation Hdsl Display Off ModeFront Panel Screen Abbreviations MenusMajor Minor Major Minor InfoLTU Access Module Menus ScreenREG1 NTUREG2 CRC4 CASHDB3 LTU E1 HDB3 Enabled CRC4CAS HDB3 CFMLP1 and LP2 Guidellines No Alarm Conditions LTU REG NTUNET Cust NET Cust LP2 LTU LP1 REG NTUES SES UAS BPV SES UAS BPVProtection Configuration Screen Main Protection Options Settings Description Protection Configuration Option SettingsSet Circuit ID Screen Hdsl Deployment Guidelines MaintenanceTotal Access 3000 LTU Specifications Product SpecificationsWarranty and Customer Service L1-5, Issue Install the LTUs Into Total Access Prerequisite ProceduresIntroduction Materials RequiredInstall the NTU Install the DUAL-SLOT Standalone HousingDisabling Protection Switching Reset ALL Equipment to Operating ConditionDisabling Protection Switching Adjust Wiring at Dual Remote HousingL1-5, Issue Install the DS3 MUX Modules Unpack and Inspect the the Total Access DS3 MUX ModulesProvision the DS3 MUX Table B-1. Faceplate LED IndicatorsProvision the LTU Install the LTUInstall the NTU into the Dual-Slot Remote Housing 61182007L1-5A L1-5, Issue L1-5, Issue