Table B-1. Faceplate LED Indicators
| POWER - Yellow |
| STATUS - Green |
ONLINE | TEST - Off |
| LOCKOUT - Off |
| ONLINE - Green |
|
|
| POWER - Yellow |
| STATUS - Green |
OFFLINE | TEST - Off |
| LOCKOUT - Off |
| ONLINE - Off |
|
|
NOTE
Only one DS3 MUX is required for any data circuit to be operational. Two modules are used for electronics redundancy of the DS3 circuit.
2.2 Provision the DS3 MUX
NOTE
There are no settings on the SCU that will affect APS operation of either the DS3 MUX units or the LTU line cards.
2.2.1Logon to Total Access system.
2.2.2If you are building a new DS3 circuit, provision the DS3 MUX modules according to circuit parameters. If the HDSL
2.2.3When channel mapping the DS3 MUX to individual slots configured for protection switching, it is necessary to map a channel only to the MAIN (odd- numbered) slot. If a fault condition occurs and a protection switch is made from the MAIN circuit to the AUX circuit, the channel is temporarily mapped by the DS3 MUX into the AUX
For this procedure, the technician needs to know which embedded G.703 in the incoming DS3 data stream to map to the appropriate APS slot in the Total Access 3010. Do not continue without this information. In a newly installed DS3 MUX, thathas not been changed from factory defaults, the embedded G.703s in the DS3 will be mapped to the
a.Access the Main Menu of the DS3 MUX module and select Option 8, Channel Mapping.
b.At the bottom of the screen where you see “Selection or Enter Mapping (E1#/Slot#)”, enter the number of the embedded G.703 followed by “/” and the appropriate slot number, then <Enter>. This action will assign the desired G.703 to the slot in the Total Access 3010.
WARNING
Assigning the incorrect embedded G.703 from the DS3 to a slot in the Total Access 3010 could disrupt existing traffic.
2.2.4APS configuration of the DS3 MUX units is NOT required for the LTUs to be in
NOTE - APS Faceplate Pushbutton -
1.When activated with the Test/Enable switch on the Offline unit, it forces a switch to protection. (Offline MUX becomes Online MUX).
2.When activated with the Test/Enable switch from the ONLINE unit, it toggles the APS Lockout Status.
Section |