RJ-45 cable connections are made to both the front and rear of the ENIU. DB-9 (command line interface) connection is made on the front and the power connection is made on the rear. A rear view of the ENIU is shown in Figure 2-2 on page 2-3. A front view is provided below in Figure 2-4.

20383-A1

Figure 2-4. ENIU Front View with RJ-45 Connector

RJ-45 Ethernet Cables

Step

Action

1Each ENIU has an RJ-45 connector located on the front and rear. Use this connector when making the copper Ethernet connections. If an RJ-45 Patchcord is provided, proceed to Step 2. The following steps describe how to make your own RJ-45 Patchcord. Pinout information is shown in Table 2-1 on page 2-5, Table 2-2 on page 2-5, and Figure 2-5.

PIN 1

 

RJ-JACK

 

PIN 8

 

 

 

11899-A

 

 

 

Figure 2-5. RJ-45 Connector Wiring

 

a. Use Cat5e or better cable, strip back cable jacket to expose the four wire pairs, the metallic sheath,

 

and drain wire (if present).

 

 

 

b. Cut off metallic sheath and drain wire (if present) so that it is even with the outer jacket of the cables.

 

c. IEEE Specification for Ethernet 10 or 100BaseT(X) requires that two twisted pairs be used and one

 

pair is connected to pins 1 and 2, and the second pair is connected to pins 3 and 6.

 

d. IEEE Specification for Ethernet 1000BaseT requires that four twisted pairs are used. One pair is

 

connected to pins 1 and 2, pair two is connected to pins 3 and 6, pair three is connected to pins 4

 

and 5, and pair four is connected to pins 7 and 8.

 

 

 

 

 

2

Connect Ethernet RJ-45 patchcords to the corresponding receptacles on the ENIU.

2-4

AIWN-UM-7001-01

Image 16
Contents Ethernet Network Interface Unit Eniu Revision History Table of Contents Table of Contents August 7 AIWN-UM-7001-01 List of Figures List of Figures August 7 AIWN-UM-7001-01 List of Tables AIWN-UM-7001-01 ViiList of Tables August 7 Viii AIWN-UM-7001-01 About this Manual IntroductionOrganization Intended AudienceAbout This Manual August 7 Inspecting Your ShipmentReader Alert Meaning Overview Product DescriptionFront Panel Eniu LED Indicators and ControlsOverview August 7 Desktop Installation InstallationSurface Mount Installation Installation August 7 Power and Ground ConnectionsGround Connection Eniu Rear View with RJ-45 Connector Power Connection Four-Pin Power Plug Wiring DiagramEniu Front View with RJ-45 Connector RJ-45 Ethernet Cables Cabling100 Mbps Ethernet RJ-45 Connector Pin # BaseT Ethernet RJ-45 Connector Pin #Function Optical CablesEIA-232 Communication Port Defaults DB-9 Communications CableCommand Prompt COMMAND-LINE Interface CLICLI Command Prompts Effective privilege Commands Overview Commands ListSecurity Initial SET-UPGET Configuration ConfigurationSET Networksubscriber Interface Speed 101001000 Autoforce GET Configuration GET Loopback Status SET Error Forwarding ON/OFFSET Keep Alive Onoff SET Loopback OnoffOAM Configuration SET OAM ConfigurationSET Echo Onoff Clear System NameSET Exfo OAM Configuration SET OAM Mode ActivepassiveoffSET Discovery Mode Onoff SET Swap Address Mode OnoffAugust 7 Provisioning User and Privilege Settings Performance and AlarmsConfigure Alarm Thresholds Purpose GET UsersGET Temperature GET Network Optical Power GET Subscriber Optical PowerGET Optical Thresholds Clear Performance StatusReset ExitGET Inventory SET LED TestProvisioning August 7 AIWN-UM-7001-01 Specifications Appendix a Specifications August 7 AIWN-UM-7001-01 Product Support Appendix B Product Support August 7 AIWN-UM-7001-01 Glossary AIWN-UM-7001-01 GL-1Glossary August 7 GL-2 AIWN-UM-7001-01 Certification and Warranty World Headquarters For Technical Assistance