Reference for the User Interface |
|
| |
|
| On the advanced page the SFP and the SMA Data pattern can be adjusted | |
| NOTE | ||
|
| independently. |
|
|
|
|
|
|
| SFP Error Insertion Rate: |
|
|
| This drop down list gives a set of Error | Insertion Rates that can be |
|
| inserted for the SFP output. |
|
|
| SMA Error Insertion Rate: |
|
|
| This drop down list gives a set of Error | Insertion Rates that can be |
|
| inserted for the SFP output. |
|
|
| Both the lists contain the same set of Error Insertion Rates. The following | |
| NOTE | ||
|
| screen shows this list. |
|
|
|
|
|
Trigger Out:
The Trigger Out lists a set of clock triggers. The list is shown below:
Error Detector
Gating Time:
The Gating Time can be set in terms of hour, minute, and seconds.
The maximum gating time is 168 hours 59 minutes and 59 seconds.
BER and Advanced BER Tab
BER
Gating BER Bar
This BER Bar indicates the Bit Error during the Gating Period. Once the Gating Period is complete this Bar turns green if the test passes (Gating BER is 0.0), and turns red if the test fails (Gating BER > 0.0).