Agilent Technologies N5980A manual Safety Summary

Page 3

Safety Summary

General Safety Precautions

General

Ground the Instrument

The following general safety precautions must be observed during all phases of operation of this instrument. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the instrument.

Agilent Technologies Inc. assumes no liability for the customer's failure to comply with these requirements.

Before operation, review the instrument and manual for safety markings and instructions. You must follow these to ensure safe operation and to maintain the instrument in safe condition.

This product is a Safety Class 1 instrument (provided with a protective earth terminal). The protective features of this product may be impaired if it is used in a manner not specified in the operation instructions.

All Light Emitting Diodes (LEDs) used in this product are Class 1 LEDs as per IEC 60825-1.

Environment Conditions

This instrument is intended for indoor use in an installation category II, pollution degree 2 environment. It is designed to operate at a maximum relative humidity of 95% and at altitudes of up to 2000 meters.

Refer to the specifications tables for the ac mains voltage requirements and ambient operating temperature range.

Before Applying Power

Verify that all safety precautions are taken. The power cable inlet of the instrument serves as a device to disconnect from the mains in case of hazard. The instrument must be positioned so that the operator can easily access the power cable inlet. When the instrument is rack mounted the rack must be provided with an easily accessible mains switch.

To minimize shock hazard, the instrument chassis and cover must be connected to an electrical protective earth ground. The instrument must be connected to the ac power mains through a grounded power cable, with the ground wire firmly connected to an electrical ground (safety ground) at the power outlet. Any interruption of the protective (grounding) conductor or disconnection of the protective earth terminal will cause a potential shock hazard that could result in personal injury.

Do Not Operate in an Explosive Atmosphere

Do not operate the instrument in the presence of flammable gases or fumes.

Do Not Remove the Instrument Cover

Operating personnel must not remove instrument covers. Component replacement and internal adjustments must be made only by qualified personnel.

Instruments that appear damaged or defective should be made inoperative and secured against unintended operation until they can be repaired by qualified service personnel.

Image 3
Contents Agilent 125 Gb/s Serial Bert Herrenberger Str Revision 1.0 MaySafety Summary Environmental Information Contents Programming Reference Introduction CD content is Inspect ShipmentSerial Bert Front Panel Connect the InstrumentTo Connect N5980A Rear PanelSerial Bert setup diagram Install User Software for N5980ATo Install the User Software for N5980A Select the folder in which N5980A will be saved To Access N5980A Demo Offline Introduction Advanced ModeRunning the BER Test Setup Setting the Instrument ParametersAdvanced BER displays Gating BER and the Elapsed Gating Time Viewing the ResultsAdvanced Mode Store SettingFile Menu Connection Menu Each PC can control only one N5980A ConnectError Indicators Help MenuInfo Error BER BarSync Loss Setup and Advanced Tab GeneralGenerator SMA Data Pattern Error DetectorInput SFP Data PatternGating BER Bar BER and Advanced BER TabAdvanced BER Gating ErrorsActual Errors Error Detector PatternAgilent N5980A Command Summary Common Command SummaryScpi Instrument Command List- Reference Common CommandsID Query Option Query Read error queueLoad factory default setting Operation completeDatarate Store current settingRecall setting All ChannelsEither sets or gets the pattern of the SMA output SMA Output Electrical GeneratorPattern SOUR1PATTOutput Level Error InsertionAdd Single Error Insertion RateSFP Output Optical Generator SOUR2PATTEither sets or gets the pattern of the SFP output SOUR2PATTEADDRATE SOUR2PATTEADD OnceSyntax SOUR2PATTEADD Once SENS1PATT? Trigger OutputDetected Pattern SOUR3PATTSynchronization mode Actual Bit Error RateActual Number of Errors Start Gating Gating Bit Error RateGating Number of Errors Gating TimeSENS1INP Description Selects the input for the error detectorGating Progress Input SelectionSample Code Communicate with the instrument Programming Reference