Agilent Technologies N5980A manual Error Insertion, Insertion Rate, Add Single Error, Output Level

Page 35

Programming Reference

Error Insertion

The error insertion is capable to enforce a given error ratio, and to add single errors into the data stream. Both are available in parallel.

Insertion Rate

Syntax

Description

Available Insertion Rate

:SOUR1:PATT:EADD:RATE

:SOUR1:PATT:EADD:RATE? :SOUR1:PATT:EADD:RATE NR3

Either sets or gets the error insertion rate. Only the listed error rates are available. If another value is specified while sending the command, the error rate will be rounded to the next available value.

Inserted error rate

Parameter

None

0

1e-3

1e-3

1e-4

1e-4

1e-5

1e-5

1e-6

1e-6

1e-7

1e-7

1e-8

1e-8

1e-9

1e-9

Add Single Error

:SOUR1:PATT:EADD

Syntax :SOUR1:PATT:EADD ONCE

Description Adds a single error to the generated data stream. This is available even if the cyclic error insertion is active.

Output Level

Syntax

Description

Available Output Levels

:SOUR1:VOLT

:SOUR1:VOLT?

:SOUR1:VOLT ECLLVDS

This either sets or gets the output level. The output is always AC. Specifying the output level actually changes only the amplitude of the generated electrical signal.

Parameter Level

ECL850mV

LVDS 400mV

N5980A User Guide

35

Image 35
Contents Agilent 125 Gb/s Serial Bert Herrenberger Str Revision 1.0 MaySafety Summary Environmental Information Contents Programming Reference Introduction Serial Bert CD content isInspect Shipment Front Panel Connect the InstrumentTo Connect N5980A Rear PanelSerial Bert setup diagram Install User Software for N5980ATo Install the User Software for N5980A Select the folder in which N5980A will be saved To Access N5980A Demo Offline Introduction Advanced ModeRunning the BER Test Setup Setting the Instrument ParametersAdvanced BER displays Gating BER and the Elapsed Gating Time Viewing the ResultsFile Menu Advanced ModeStore Setting Connection Menu Each PC can control only one N5980A ConnectInfo Error IndicatorsHelp Menu Sync Loss ErrorBER Bar Generator Setup and Advanced TabGeneral SMA Data Pattern Error DetectorInput SFP Data PatternGating BER Bar BER and Advanced BER TabAdvanced BER Gating ErrorsActual Errors Error Detector PatternAgilent N5980A Command Summary Common Command SummaryID Query Scpi Instrument Command List- ReferenceCommon Commands Option Query Read error queueLoad factory default setting Operation completeDatarate Store current settingRecall setting All ChannelsEither sets or gets the pattern of the SMA output SMA Output Electrical GeneratorPattern SOUR1PATTOutput Level Error InsertionAdd Single Error Insertion RateEither sets or gets the pattern of the SFP output SFP Output Optical GeneratorSOUR2PATT Syntax SOUR2PATTEADD Once SOUR2PATTEADDRATESOUR2PATTEADD Once SENS1PATT? Trigger OutputDetected Pattern SOUR3PATTActual Number of Errors Synchronization modeActual Bit Error Rate Start Gating Gating Bit Error RateGating Number of Errors Gating TimeSENS1INP Description Selects the input for the error detectorGating Progress Input SelectionSample Code Communicate with the instrument Programming Reference